The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
A survey of condition monitoring and protection methods for medium voltage induction motors
Abstract
Medium voltage induction motors are widely used in industry and are essential to industrial processes. The breakdown of these medium voltage motors not only leads to high repair expenses, but also causes extraordinary financial losses due to unexpected downtime. To provide reliable condition monitoring and protection for medium voltage motors, this paper presents a comprehensive survey of the existing condition monitoring and protection methods in the following five areas: thermal protection and temperature estimation, stator insulation monitoring and fault detection, bearing fault detection, broken rotor bar/end-ring detection, and air-gap eccentricity detection. For each category, the related features of medium voltage motors are discussed; the effectiveness of the existing methods are discussed in terms of their robustness, accuracy and implementation complexity; recommendations for the future research in these areas are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Harris, T. A., & Crecelius, W. J. (1986) · Journal of Tribology · doi:10.1115/1.3261135 · Cited by 1,701
Lumped parameter thermal model for electrical machines of TEFC design
Mellor, P. H., Roberts, D., & Turner, D. R. (1991) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1991.0025 · Cited by 885
Neural-network-based motor rolling bearing fault diagnosis
Li, B., Chow, M.-Y., Tipsuwan, Y., & Hung, J. C. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873214 · Cited by 797
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
Self-citationMotor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638
Self-citationReport of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Noninvasive detection of broken rotor bars in operating induction motors
Kliman, G. B., Koegl, R. A., Stein, J., Endicott, R. D., & Madden, M. W. (1988) · IEEE Transactions on Energy Conversion · doi:10.1109/60.9364 · Cited by 525
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512
Cited by
Deep Learning Algorithms for Bearing Fault Diagnostics—A Comprehensive Review
Zhang, S., Zhang, S., Wang, B., & Habetler, T. G. (2020) · IEEE Access · doi:10.1109/access.2020.2972859 · Cited by 913
Self-citationGangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Prieto, M. D., Cirrincione, G., Espinosa, A. G., Ortega, J. A., & Henao, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2219838 · Cited by 461
Extended Kalman Filtering for Remaining-Useful-Life Estimation of Bearings
Singleton, R. K., Strangas, E. G., & Aviyente, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336616 · Cited by 364
Electrical bearing failures in electric vehicles
He, F., Xie, G., & Luo, J. (2020) · Friction · doi:10.1007/s40544-019-0356-5 · Cited by 303
Methodology for fault detection in induction motors via sound and vibration signals
Delgado-Arredondo, P. A., Morinigo-Sotelo, D., Osornio-Rios, R. A., Avina-Cervantes, J. G., Rostro-Gonzalez, H., & Romero-Troncoso, R. D. J. (2017) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2016.06.032 · Cited by 266
Frosini, L., Harlisca, C., & Szabo, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361115 · Cited by 264
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Rangel-Magdaleno, J., Peregrina-Barreto, H., Ramirez-Cortes, J., Morales-Caporal, R., & Cruz-Vega, I. (2016) · Shock and Vibration · doi:10.1155/2016/3530464 · Cited by 48
Metadata
- Authors
- Zhang, P., Du, Y., Habetler, T. G., & Lu, B.
- Venue
- 2009 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2009-09
- Pages
- 3165-3174
- OpenAlex
- W2099250634
- Cited by
- 524
- References
- 106
- FWCI
- 24.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.