The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
A survey of condition monitoring and protection methods for medium voltage induction motors
Abstract
Medium voltage induction motors are widely used in industry and are essential to industrial processes. The breakdown of these medium voltage motors not only leads to high repair expenses, but also causes extraordinary financial losses due to unexpected downtime. To provide reliable condition monitoring and protection for medium voltage motors, this paper presents a comprehensive survey of the existing condition monitoring and protection methods in the following five areas: thermal protection and temperature estimation, stator insulation monitoring and fault detection, bearing fault detection, broken rotor bar/end-ring detection, and air-gap eccentricity detection. For each category, the related features of medium voltage motors are discussed; the effectiveness of the existing methods are discussed in terms of their robustness, accuracy and implementation complexity; recommendations for the future research in these areas are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Harris, T. A., & Crecelius, W. J. (1986) · Journal of Tribology · doi:10.1115/1.3261135 · Cited by 1,701
Lumped parameter thermal model for electrical machines of TEFC design
Mellor, P. H., Roberts, D., & Turner, D. R. (1991) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1991.0025 · Cited by 885
Neural-network-based motor rolling bearing fault diagnosis
Li, B., Chow, M.-Y., Tipsuwan, Y., & Hung, J. C. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873214 · Cited by 797
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
Self-citationMotor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638
Self-citationReport of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Noninvasive detection of broken rotor bars in operating induction motors
Kliman, G. B., Koegl, R. A., Stein, J., Endicott, R. D., & Madden, M. W. (1988) · IEEE Transactions on Energy Conversion · doi:10.1109/60.9364 · Cited by 525
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Cameron, J. R., Thomson, W. T., & Dow, A. B. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0022 · Cited by 512
Transient analysis of cage induction machines under stator, rotor bar and end ring faults
Toliyat, H. A., & Lipo, T. A. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.391888 · Cited by 489
Quantitative evaluation of induction motor broken bars by means of electrical signature analysis
Bellini, A., Filippetti, F., Franceschini, G., Tassoni, C., & Kliman, G. B. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952499 · Cited by 483
The detection of inter-turn short circuits in the stator windings of operating motors
Joksimovic, G. M., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873216 · Cited by 471
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Dorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
AI techniques in induction machines diagnosis including the speed ripple effect
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.658729 · Cited by 442
Dorrell, D. G., Thomson, W. T., & Roach, S. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530349 · Cited by 367
Condition monitoring of electrical machines
Tavner, P., & Penman, J. (1987) · Durham Research Online (Durham University) · Cited by 353
Nandi, S., Ahmed, S., & Toliyat, H. A. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.937205 · Cited by 340
Assessment of the Reliability of Motors in Utility Applications - Updated
Albrecht, P. F., Appiarius, J. C., McCoy, R. M., Owen, E. L., & Sharma, D. K. (1986) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.1986.4765668 · Cited by 334
Statistical analysis of sound and vibration signals for monitoring rolling element bearing condition
Heng, R. B. W., & Nor, M. J. M. (1998) · Applied Acoustics · doi:10.1016/s0003-682x(97)00018-2 · Cited by 333
A High-Resolution Frequency Estimation Method for Three-Phase Induction Machine Fault Detection
Kia, S. H., Henao, H., & Capolino, G.-A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899826 · Cited by 325
Basic vibration signal processing for bearing fault detection
McInerny, S. A., & Dai, Y. (2003) · IEEE Transactions on Education · doi:10.1109/te.2002.808234 · Cited by 321
Daviu, J. A. A., Riera‐Guasp, M., Folch, J. R., & Palomares, M. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876082 · Cited by 317
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Marques Cardoso, A. J., Cruz, S. M. A., & Fonseca, D. S. B. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.790920 · Cited by 315
A new approach to on-line turn fault detection in AC motors
Kliman, G. B., Premerlani, W. J., Koegl, R. A., & Hoeweler, D. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557113 · Cited by 303
A Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Self-citationNandi, S., Ahmed, S., & Toliyat, H. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311622 · Cited by 298
Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines
Bachir, S., Tnani, S., Trigeassou, J.-C., & Champenois, G. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.874258 · Cited by 287
Bearing Damage Detection via Wavelet Packet Decomposition of the Stator Current
Eren, L., & Devaney, M. J. (2004) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2004.823323 · Cited by 282
Effects of time-varying loads on rotor fault detection in induction machines
Schoen, R. R., & Habetler, T. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.395302 · Cited by 272
Self-citationYazici, B., & Kliman, G. B. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.753640 · Cited by 266
da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.909060 · Cited by 266
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345492 · Cited by 264
Self-citationCruz, S. M. A., & Marques Cardoso, A. J. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.881141 · Cited by 258
Lee, S. B., Tallam, R. M., & Habetler, T. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810848 · Cited by 248
Self-citationPerformance analysis of a three-phase induction motor under mixed eccentricity condition
Nandi, S., Bharadwaj, R. M., & Toliyat, H. A. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.801995 · Cited by 245
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475698 · Cited by 239
Self-citationFailure identification and analysis for high-voltage induction motors in the petrochemical industry
Thorsen, O. V., & Dalva, M. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.777188 · Cited by 228
A method for dynamic simulation of air-gap eccentricity in induction machines
Toliyat, H. A., Arefeen, M. S., & Parlos, A. G. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.511649 · Cited by 227
Ordaz-Moreno, A., de Jesus Romero-Troncoso, R., Vite-Frias, J. A., Rivera-Gillen, J. R., & Garcia-Perez, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918613 · Cited by 227
Martins, J. F., Pires, V. F., & Pires, A. J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888790 · Cited by 219
A novel approach for broken-rotor-bar detection in cage induction motors
Milimonfared, J., Kelk, H. M., Nandi, S., Minassians, A. D., & Toliyat, H. A. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.793359 · Cited by 219
Monitoring of defects in induction motors through air-gap torque observation
Hsu, J. S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464514 · Cited by 217
Lee, S.-B., & Habetler, T. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811789 · Cited by 202
Self-citationImmovilli, F., Cocconcelli, M., Bellini, A., & Rubini, R. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025288 · Cited by 201
Closed-loop control impact on the diagnosis of induction motors faults
Bellini, A., Filippetti, F., Franceschini, G., & Tassoni, C. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.871280 · Cited by 199
Analysis of Cage Induction Motors with Stator Winding Faults
Williamson, S., & Mirzoian, K. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.319221 · Cited by 183
Ayhan, B., Chow, M.-Y., & Song, M.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878301 · Cited by 182
On-field experience with online diagnosis of large induction motors cage failures using MCSA
Bellini, A., Filippetti, F., Franceschini, G., Tassoni, C., Passaglia, R., Saottini, M., Tontini, G., Giovannini, M., & Rossi, A. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800591 · Cited by 176
Bearing Condition Monitoring Methods for Electric Machines: A General Review
Zhou, W., Habetler, T. G., & Harley, R. G. (2007) · 2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2007.4393062 · Cited by 174
Self-citationLiu, Z., Yin, X., Zhang, Z., Chen, D., & Chen, W. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.832052 · Cited by 172
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344) · doi:10.1109/ias.2002.1043741 · Cited by 167
Self-citationBearing Fault Detection Via Stator Current Noise Cancellation and Statistical Control
Zhou, W., Habetler, T. G., & Harley, R. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005018 · Cited by 165
Self-citationOnline stator fault diagnosis in inductionmotors
Arkan, M., Perović, D. K., & Unsworth, P. (2001) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20010588 · Cited by 164
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811784 · Cited by 163
Self-citationNandi, S., & Toliyat, H. A. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.980363 · Cited by 160
Cruz, S. M. A., & Cardoso, A. J. M. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847975 · Cited by 158
Schoen, R. R., & Habetler, T. G. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.649970 · Cited by 154
Self-citationFinite-Element Transient Analysis of Induction Motors Under Mixed Eccentricity Fault
Faiz, J., Ebrahimi, B. M., Akin, B., et al. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.908479 · Cited by 153
Comparative investigation of diagnostic media for induction motors: a case of rotor cage faults
Trzynadlowski, A. M., & Ritchie, E. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873218 · Cited by 152
Insulation failure prediction in AC machines using line-neutral voltages
Cash, M. A., Habetler, T. G., & Kliman, G. B. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.738983 · Cited by 149
Self-citationFault detection of broken rotor bars in induction motor using a global fault index
Didier, G., Ternisien, E., Caspary, O., et al. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.861368 · Cited by 144
Schoen, R. R., & Habetler, T. G. (2002) · Conference record · doi:10.1109/ias.1996.557108 · Cited by 143
Self-citationÖnel, İ. Y. İ. Y., & Benbouzid, M. (2008) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.918535 · Cited by 141
The Use of the Wavelet Approximation Signal as a Tool for the Diagnosis of Rotor Bar Failures
Riera‐Guasp, M., Daviu, J. A. A., Roger-Folch, J., et al. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.921432 · Cited by 137
Bearing Fault Detection via Autoregressive Stator Current Modeling
Stack, J. R., Habetler, T. G., & Harley, R. G. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.827797 · Cited by 135
Self-citationBriz, F., Degner, M. W., Zamarrón, A., & Guerrero, J. M. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.813746 · Cited by 132
Condition monitoring of electrical drives
Penman, J., Dey, M. N., Tait, A. J., & Bryan, W. E. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0019 · Cited by 127
Kohler, J. L., Sottile, J., & Trutt, F. C. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.802935 · Cited by 121
Eltabach, M., Charara, A., & Zein, I. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.822083 · Cited by 113
Alternatives for assessing the electrical integrity of induction motors
Kohler, J. L., Sottile, J., & Trutt, F. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.158836 · Cited by 109
Huang, X., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900607 · Cited by 107
Self-citationMultiple Signature Processing-Based Fault Detection Schemes for Broken Rotor Bar in Induction Motors
Ayhan, B., Chow, M., & Song, M.-H. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.842393 · Cited by 105
Online Diagnostics in Inverter-Fed Induction Machines Using High-Frequency Signal Injection
Briz, F., Degner, M. W., Díez, A. B., & Guerrero, J. M. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.830792 · Cited by 104
Ferrah, A., Hogben-Laing, P. J., Bradley, K. J., Asher, G. M., & Woolfson, M. S. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.643018 · Cited by 103
An advanced Park's vectors approach for bearing fault detection
Zarei, J., & Poshtan, J. (2008) · Tribology International · doi:10.1016/j.triboint.2008.06.002 · Cited by 102
Stone, G. C., & Kapler, J. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.715501 · Cited by 101
Bearing failures diagnosis in three-phase induction motors by extended Park's vector approach
da Silva, J. P. L. R., & Cardoso, A. J. M. (2005) · doi:10.1109/iecon.2005.1569315 · Cited by 95
Kral, C., Wieser, R. S., Pirker, F., et al. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873212 · Cited by 92
Culbert, I., & Rhodes, W. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.889915 · Cited by 86
Mohammed, O. A., Abed, N. Y., & Ganu, S. (2006) · IEEE International Magnetics Conference · doi:10.1109/intmag.2006.376493 · Cited by 85
Supangat, R., Ertuğrul, N., Soong, W. L., Gray, D. A., Hansen, C. H., & Grieger, J. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060060 · Cited by 84
An Online Technique for Monitoring the Insulation Condition of AC Machine Stator Windings
Lee, S. B., Younsi, K., & Kliman, G. B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853760 · Cited by 84
Detection of Stator Faults in Induction Machines Using Residual Saturation Harmonics
Nandi, S. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.880838 · Cited by 83
On innovative methods of induction motor interturn and broken-bar fault diagnostics
Mirafzal, B., & Demerdash, N. A. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.870038 · Cited by 81
Monitoring of induction Machines by maximum covariance method for frequency tracking
Bellini, A., Franceschini, G., & Tassoni, C. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.861320 · Cited by 80
Sottile, J., Trutt, F. C., & Kohler, J. L. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.802921 · Cited by 80
Briz, F., Degner, M. W., Guerrero, J. M., & García, P. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027198 · Cited by 78
Culbert, I., & Rhodes, W. (2006) · IEEE IAS Petroleum and Chemical Industry Conference (PCIC) · doi:10.1109/pcicon.2005.1524544 · Cited by 78
Diagnosis of Induction Machines' Rotor Faults in Time-Varying Conditions
Stefani, A., Bellini, A., & Filippetti, F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2016517 · Cited by 77
Stator Current-Based Bearing Fault Detection Techniques: A General Review
Zhou, W., Habetler, T. G., & Harley, R. G. (2007) · IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2007.4393063 · Cited by 74
Self-citationDynamic simulation of cage induction machine with air gap eccentricity
Joksimović, G. (2005) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20041229 · Cited by 72
Razik, H., Corrêa, M. B. D. R., & da Silva, E. R. C. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029580 · Cited by 70
The detection of interturn short circuits in the stator windings of operating motors
Joksimović, G., & Penman, J. (2002) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.1998.724020 · Cited by 66
Interturn Fault Diagnosis in Induction Motors Using the Pendulous Oscillation Phenomenon
Mirafzal, B., Povinelli, R. J., & Demerdash, N. A. O. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853767 · Cited by 64
Wu, L., Huang, X., Habetler, T. G., et al. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900542 · Cited by 57
Self-citationKallesøe, C. S., Izadi‐Zamanabadi, R., Vadstrup, P., & Rasmussen, H. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900494 · Cited by 55
Bossio, G. R., DeAngelo, C., García, G. O., Solsona, J. A., & Valla, M. I. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.851038 · Cited by 48
Müller, G., & Landy, C. F. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.808338 · Cited by 48
An Integrated on-Line Motor Protection System
Farag, S. F., Bartheld, R. G., & Habetler, T. G. (1996) · IEEE Industry Applications Magazine · doi:10.1109/2943.485759 · Cited by 46
Self-citationInverter statistics for online detection of stator asymmetries in inverter-fed induction motors
Wolbank, T. M., Loparo, K. A., & Wohrnschimmel, R. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.814576 · Cited by 42
Bossio, G. R., Angelo, C. H. D., Solsona, J. A., et al. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874218 · Cited by 38
Rotor fault detection in closed loop induction motors drives by electric signal analysis
Concari, C., Franceschini, G., & Tassoni, C. (2008) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2008.4800048 · Cited by 17
Diagnosis of mechanical faults by spectral kurtosis energy
Bellini, A., Cocconcelli, M., Immovilli, F., & Rubini, R. (2008) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2008.4758452 · Cited by 15
Cited by
Deep Learning Algorithms for Bearing Fault Diagnostics—A Comprehensive Review
Zhang, S., Zhang, S., Wang, B., & Habetler, T. G. (2020) · IEEE Access · doi:10.1109/access.2020.2972859 · Cited by 913
Self-citationGangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Prieto, M. D., Cirrincione, G., Espinosa, A. G., Ortega, J. A., & Henao, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2219838 · Cited by 461
Extended Kalman Filtering for Remaining-Useful-Life Estimation of Bearings
Singleton, R. K., Strangas, E. G., & Aviyente, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336616 · Cited by 364
Metadata
- Authors
- Zhang, P., Du, Y., Habetler, T. G., & Lu, B.
- Venue
- 2009 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2009-09
- Pages
- 3165-3174
- OpenAlex
- W2099250634
- Cited by
- 524
- References
- 106
- FWCI
- 24.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.