Design and optimisation of magnetic structures for lumped Inductive Power Transfer systems
The DOI matches its Crossref record.
Abstract
A solution which enables safe, efficient and convenient overnight recharging of electric vehicles is needed. Inductive Power Transfer (IPT) is capable of meeting these needs however the main limiting factor is the performance of the magnetic structures (termed power pads) which help transfer the power efficiently. These pads are required to transfer 2-5 kW with a large air gap and have good tolerance to misalignment. They also need to be as light-weight, durable and cost effective as possible. An approach using 3D finite-element analysis modelling is used here to optimise the power pads. This technique is viable since measured and simulated results differ by 10% at most. Power pads have been built which allow 2 kW of power to be transferred over a 200 mm air gap with a tolerance of 130 mm in the horizontal direction. The leakage magnetic flux is also investigated via simulation showing that the designed pads comply with human exposure regulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212917 · Cited by 3,118
“Challenges of roadbed charging include high power ratings, poor coupling [146], [147], high supply-voltage requirements [121], loop losses, high magnetization current due to loose coupling [32], [135], lateral misalignment [148], [149], the large air gap [150], and stray field coupling.”
BackgroundModern Trends in Inductive Power Transfer for Transportation Applications
Covic, G. A., & Boys, J. T. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2264473 · Cited by 1,263
“The authors are with the Department of Electrical and Electronic Engineering, The University of Auckland, Auckland 1142, New Zealand (e-mail: ga.covic@auckland.ac.nz; j.boys@auckland.ac.nz).”
BackgroundMethodInfluentialSelf-citationCovic, G. A., & Boys, J. T. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244536 · Cited by 1,223
Self-citationDai, J., & Ludois, D. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2415253 · Cited by 638
Inductive Wireless Power Transfer Charging for Electric Vehicles—A Review
Mahesh, A., Chokkalingam, B., & Mihet-Popa, L. (2021) · IEEE Access · doi:10.1109/access.2021.3116678 · Cited by 513
Metadata
- Authors
- Budhia, M., Covic, G. A., & Boys, J. T.
- Venue
- 2009 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2009-09
- Pages
- 2081-2088
- OpenAlex
- W2117051910
- Cited by
- 103
- References
- 0
- FWCI
- 15.84
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and optimisation of magnetic structures for lumped Inductive Power Transfer systems. https://app.cochat.ai/papers/10.1109/ecce.2009.5316197
- The paper
- Budhia, M., Covic, G. A., & Boys, J. T. (2009). Design and optimisation of magnetic structures for lumped Inductive Power Transfer systems. 2009 IEEE Energy Conversion Congress and Exposition. https://doi.org/10.1109/ecce.2009.5316197
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.