The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Comparison of PR controller and damped PR controller for grid current control of LCL filter based grid-tied inverter under frequency variation and grid distortion
Open accessAbstract
Voltage Source Inverters (VSIs) are essential component for integration of renewable energy sources into utility grid or microgrid. Most of the utility grid regulation standards demand high quality sinusoidal current regulation by these inverters with renewable sources, which necessitates the use of LCL filters at the output of VSIs. Different load conditions and other factors influence grid conditions, such as voltage profile, harmonic distortion and frequency variation. The scope of this paper include comparison of effects on grid current of LCL filter based inverter while using PR controller and damped PR controller under distorted grid voltage and frequency variation conditions. The effects are analyzed through simulation studies in MATLAB/PLECS and real time simulation studies are carried out in Typhoon HIL environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Past work using HIL devices showcased grid-tied AC/DC converter controllers and their impact on basic grid models.
“Past work using HIL devices showcased grid-tied AC/DC converter controllers and their impact on basic grid models [9], [10].”
From Controller Hardware-in-the-loop (C-HIL) Testing of Decentralized EV-Grid Integration (2022) · cites this paper as [10]
Citations
Cites
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,410
Grid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 902
Jia, Y., Zhao, J., & Fu, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2264098 · Cited by 206
Wessels, C., Dannehl, J., & Fuchs, F. W. (2008) · PESC record · doi:10.1109/pesc.2008.4592502 · Cited by 110
Mohamed, Y. A. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098372 · Cited by 88
A Control Design Approach for Three-Phase Grid-Connected Renewable Energy Resources
Khajehoddin, S. A., Karimi-Ghartemani, M., Jain, P. K., et al. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2158457 · Cited by 86
A New Current Feedback PR Control Strategy for Grid-Connected VSI with an LCL Filter
Shen, G., Zhu, X., Chen, M., et al. (2009) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802876 · Cited by 29
Madhusoodhanan, S., Bhattacharya, S., & Hatua, K. (2014) · IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2014.6803424 · Cited by 14
Self-citationHarmonic current elimination for single-phase rectifiers based on PR controller with notch filter
Huang, J., Lu, Y., Zhang, B., et al. (2012) · Cited by 9
Zhou, Y., Duan, S., Liu, F., et al. (2008) · Cited by 4
Flagged first, then by citations
Cited by
Sorted by citations
Controller Hardware-in-the-loop (C-HIL) Testing of Decentralized EV-Grid Integration
Flack, C., Ucer, E., Smith, C. P., & Kisacikoglu, M. (2022) · 2022 IEEE Power & Energy Society General Meeting (PESGM) · doi:10.1109/pesgm48719.2022.9917135 · Cited by 13
Metadata
- Authors
- Chattopadhyay, R., De, A., & Bhattacharya, S.
- Affiliations
- North Carolina State University (US)
- Venue
- 2014 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2014-09
- Pages
- 3634-3641
- OpenAlex
- W2327525516
- Cited by
- 35
- References
- 10
- Citations by year
- 2025: 2 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 8 · 2016: 4 · 2015: 2
- FWCI
- 6.47
- Type
- conference paper
- Language
- en
- Open access
- green
- zenodo.org
- Licence
- public-domain
- Locations
- IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- proportional resonant controller, grid current control, LCL filter, grid-connected inverter, voltage source inverter, grid frequency variation, grid voltage distortion, harmonic distortion, renewable energy integration, real-time simulation, hardware-in-the-loop
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review