Cited by 35Microgrid Control and OptimizationPower Quality and HarmonicsMultilevel Inverters and Converters

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Comparison of PR controller and damped PR controller for grid current control of LCL filter based grid-tied inverter under frequency variation and grid distortion

Open access
Chattopadhyay, Ritwik, De, Ankan, Bhattacharya, Subhashish·2014·2014 IEEE Energy Conversion Congress and Exposition (ECCE)

Abstract

Voltage Source Inverters (VSIs) are essential component for integration of renewable energy sources into utility grid or microgrid. Most of the utility grid regulation standards demand high quality sinusoidal current regulation by these inverters with renewable sources, which necessitates the use of LCL filters at the output of VSIs. Different load conditions and other factors influence grid conditions, such as voltage profile, harmonic distortion and frequency variation. The scope of this paper include comparison of effects on grid current of LCL filter based inverter while using PR controller and damped PR controller under distorted grid voltage and frequency variation conditions. The effects are analyzed through simulation studies in MATLAB/PLECS and real time simulation studies are carried out in Typhoon HIL environment.

Overview

Integrity signals

Registry

Crossref · 10.1109/ecce.2014.6953895

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Chattopadhyay, R., De, A., & Bhattacharya, S.
Affiliations
North Carolina State University (US)
Venue
2014 IEEE Energy Conversion Congress and Exposition (ECCE)
Publisher
IEEE
Published
2014-09
Pages
3634-3641
OpenAlex
W2327525516
Cited by
35
References
10
Citations by year
2025: 2 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 8 · 2016: 4 · 2015: 2
FWCI
6.47
Type
conference paper
Language
en
Open access
Licence
public-domain
Locations
  • IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, public-domain)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
proportional resonant controller, grid current control, LCL filter, grid-connected inverter, voltage source inverter, grid frequency variation, grid voltage distortion, harmonic distortion, renewable energy integration, real-time simulation, hardware-in-the-loop

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review