CoChat

Hierarchical coordination of a hybrid AC/DC smartgrid with central/distributed energy storage

Open access
Arboleya, Pablo, Gonzalez-Moran, Cristina, Jorge, Pablo Garcia, Mohamed, Bassam · 2016 · 2016 IEEE Energy Conversion Congress and Exposition (ECCE)

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

This work describes a hybrid AC/DC Smart Grid distribution scheme installed at LEMUR microgrid laboratory. The control of the microgrid is carried out according to a hierarchical coordination considering the high level control. The configuration includes a microgrid (pG) connected to the main utility grid (MUG) by means of a solid state transformer (STT). The pG is formed by several nanogrids (nGs). All (nGs) are based on four wire configurations, as they are usually employed in AC distribution systems. However, the scheme is considered as a hybrid Smart Grid because the connection among different nanogrids and with the SST are DC connections. The SST is also equipped with a third port connected to a central energy storage system (CESS). The coordination between the different involved in the systems: the installed dispersed generators at nanogrid level, the nanogrids, the SST and the CESS has been implemented using a bottom-up hierarchical approach. Several configurations at nanogrid and microgrid levels are shown and analyzed. For making the coordination of the different elements of the microgrid, a fast power flow algorithm for estimating the state of the microgrid in real time was developed. In this paper the proposed structure is described paying special attention to the power flow algorithm. The results obtained with the power flow algorithm in simulations were validated at laboratory level.

Overview

Integrity signals

Registry

Crossref · 10.1109/ecce.2016.7855144

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 16 references

Cited by

See all 12

Metadata

Authors
Arboleya, P., Gonzalez-Moran, C., Jorge, P. G., & Mohamed, B.
Affiliations
Universidad de Oviedo (ES)
Venue
2016 IEEE Energy Conversion Congress and Exposition (ECCE)
Publisher
IEEE
Published
2016-09
Pages
1-7
OpenAlex
W2587944480
Cited by
12
References
16
Citations by year
2022: 2 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 5 · 2016: 1
FWCI
3.70
Type
conference paper
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
  • Consultation of the Doctoral Thesis Database (TESEO) (Ministerio de Educación, Cultura y Deporte) (submittedVersion, cc-by-nc-nd)
  • Consultation of the Doctoral Thesis Database (TESEO) (Ministerio de Educación, Cultura y Deporte) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
Keywords
microgrids, nanogrid, solid-state transformer, distributed energy storage, hierarchical control, power flow algorithm, distributed generation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hierarchical coordination of a hybrid AC/DC smartgrid with central/distributed energy storage. https://app.cochat.ai/papers/10.1109/ecce.2016.7855144
The paper
Arboleya, P., Gonzalez-Moran, C., Jorge, P. G., & Mohamed, B. (2016). Hierarchical coordination of a hybrid AC/DC smartgrid with central/distributed energy storage. 2016 IEEE Energy Conversion Congress and Exposition (ECCE). https://doi.org/10.1109/ecce.2016.7855144

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.