Online Volt-Var Control for Distribution Systems With Solid-State Transformers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In distribution power systems, feeder voltages can be very sensitive to changes in load and/or distributed generation. This paper introduces a solid-state-transformer-based local voltage-control strategy to reduce variability distribution system bus voltages. An online dynamic volt-var control (VVC) algorithm is proposed to regulate bus voltages by injecting or absorbing reactive power through a solid-state transformer (SST). The proposed algorithm does not require any communication between the SST and the substation and makes control decisions locally. The main goal of the voltage-control algorithm is to enforce strict voltage constraints on the system voltages. The proposed control algorithm is validated in a radial and meshed distribution system using PSCAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310
Cited by
Sizing and SOC Management of a Smart-Transformer-Based Energy Storage System
Kumar, C., Zhu, R., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2784389 · Cited by 71
“The advantages of the ST in the electric grid have also been demonstrated through different operational features and ancillary services, for example, damping of LV grid resonance [11], better control and sharing of the power [12], var/volt control [13], a frequencyadaptive ST in the LV grid [14], dc microgrid operatio…”
BackgroundHierarchical coordination of a hybrid AC/DC smartgrid with central/distributed energy storage
Arboleya, P., Gonzalez-Moran, C., Jorge, P. G., & Mohamed, B. (2016) · 2016 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855144 · Cited by 12
“Instead, the microgrid (μG) is connected to the main utility grid (MUG) by means of a three-port solid state transformer (SST) [9], [10].”
BackgroundHaritha, G., Kumaravel, S., & Ashok, S. (2018) · 2018 2nd International Conference on Green Energy and Applications (ICGEA) · doi:10.1109/icgea.2018.8356290 · Cited by 5
Metadata
- Authors
- Shah, D., & Crow, M. L.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2016-02
- Volume
- 31
- Issue
- 1
- Pages
- 343-350
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2276000938
- Cited by
- 94
- References
- 2
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online Volt-Var Control for Distribution Systems With Solid-State Transformers. https://app.cochat.ai/papers/10.1109/tpwrd.2015.2457442
- The paper
- Shah, D., & Crow, M. L. (2016). Online Volt-Var Control for Distribution Systems With Solid-State Transformers. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2015.2457442
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.