Design of 1500V/200kW 99.6% Efficiency Dual Active Bridge Converters Based on 1700V SiC Power MOSFET Module
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
High efficiency, high density and galvanically isolated power converters are attractive for medium voltage high power applications. This paper presents a 1.5kV/200kW bidirectional Dual Active Bridge (DAB) converter using a newly developed 1.7kV SiC MOSFET module. The intended application is megawatt scale solid state transformer (SST) and 1500V PV inverter application using modular architecture. One novel model to estimate the turn-off loss using snubber capacitors is proposed and experimentally verified. An optimized PCB-based busbar design is introduced to reduce the voltage overshoot across the SiC device, making the design suitable for 1.5kVdc applications. The mechanism of how the optimized PCB-based busbar can reduce the voltage overshoot is quantitatively interpreted and experimentally verified. The DAB converter achieved an efficiency of 98.85% at 200kW and a maximum of 99.53% at 60kW. The maximum efficiency for series-resonant mode is 99.6% at 85kW and 99.3% at 200kW. The power density is 26W/inch3 (1.6MW/m3) which is much higher than traditional industry products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The selected working frequency of the MFT is 15kHz which is based on the efficiency and dimension optimization of the whole DAB converter system[20-21].”
From Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters (2021) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Semiconductor Devices
Baliga, B. J. (2008) · Springer eBooks · doi:10.1007/978-0-387-47314-7 · Cited by 2,174
Wang, J., Chung, H. S.-H., & Li, R. T.-H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2195332 · Cited by 551
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
Caponet, M. C., Profumo, F., De Doncker, R. W., & Tenconi, A. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988833 · Cited by 231
Caponet, M. C., Profumo, F., De Doncker, R. W., & Tenconi, A. (2002) · 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018) · doi:10.1109/pesc.2000.879936 · Cited by 180
Xiao, Y., Shah, H., Chow, T. P., & Gutmann, R. J. (2004) · Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04. · doi:10.1109/apec.2004.1295856 · Cited by 168
Noppakunkajorn, J., Han, D., & Sarlioglu, B. (2015) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2015.2426503 · Cited by 79
Estimation and minimization of power loop inductance in 135 kW SiC traction inverter
Aberg, B., Moorthy, R. S. K., Yang, L., Yu, W., & Husain, I. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341257 · Cited by 43
Medium-Voltage SiC-Based Converter Laminated Bus Insulation Design and Assessment
Xu, Y., Feng, X., Wang, J., Gao, C., Burgos, R., Boroyevich, D., & Hebner, R. E. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2922332 · Cited by 41
An Accurate Calorimetric Loss Measurement Method for SiC MOSFETs
Anurag, A., Acharya, S., & Bhattacharya, S. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2920935 · Cited by 40
Nguyen, B., Zhang, X., Ferencz, A., Takken, T., Senger, R. M., & Coteus, P. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341024 · Cited by 35
Xu, W., Guo, Z., Tayebi, S. M., Rajendran, S., Sun, A., Yu, R., & Huang, A. Q. (2020) · 2020 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec39645.2020.9124401 · Cited by 28
Self-citationSwitching Loss Analysis of SiC-MOSFET based on Stray Inductance Scaling
Wãda, K., & Ando, M. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507986 · Cited by 26
Temperature dependence of breakdown in anisotropic 6H-SiC MOSFET
Li, L., Yin-tang, Y., & Chai, C. (2008) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict.2008.4734735 · Cited by 3
Cited by
Modeling and Advanced Control of Dual-Active-Bridge DC–DC Converters: A Review
Shao, S., Chen, L., Shan, Z., Gao, F., Chen, H., Sha, D., & Dragičević, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3108157 · Cited by 488
Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
Self-citationHardware Design of a 13.8-kV/3-MVA PV Plus Storage Solid-State Transformer (PVS-SST)
Xu, W., Guo, Z., Vetrivelan, A., Yu, R., & Huang, A. Q. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3082033 · Cited by 78
Self-citationXu, W., Rajendran, S., Guo, Z., Vctrivelan, A., & Huang, A. Q. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131549 · Cited by 23
Self-citationEfficiency Optimization of Dual Active Bridge Converter Based on dV/dt Snubber Capacitors
Xu, W., Vetrivelan, A., Guo, Z., Yu, R., & Huang, A. Q. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487159 · Cited by 14
Self-citation
Metadata
- Authors
- Xu, W., Yu, R. Y., Guo, Z., & Huang, A. Q.
- Affiliations
- The University of Texas at Austin (US)
- Venue
- 2020 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2020-10-11
- Pages
- 6000-6007
- OpenAlex
- W3095716777
- Cited by
- 25
- References
- 14
- Citations by year
- 2025: 7 · 2024: 1 · 2023: 10 · 2022: 3 · 2021: 4
- FWCI
- 5.98
- Type
- conference paper
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- Locations
- IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Office of Energy
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- dual active bridge converter, bidirectional DC-DC converter, SiC MOSFET modules, snubber capacitor, series resonant converter, solid-state transformer, medium-voltage power conversion, power density, galvanic isolation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.