Cited by 1Optimal Power Flow DistributionPower Quality and HarmonicsPower Systems and Renewable Energy

Technical Impacts of High Penetration of Solar Photovoltaic Systems in Low-Voltage Radial Distribution Network – Case Study

Ilahi, A.S. Ahzan Musnath, Zeeminnaj, M.R., Ahamed, M.H. Fayas, Juhaniya, A.I.S.·2024·2024 4th International Conference on Electrical Engineering (EECon)

Abstract

Rapid integration of Solar Photovoltaic (PV) based Distributed Energy Resources (DERs) at the distribution network has posed challenges to the grid operators since higher solar PV penetration coincides with the lower load demand, leading to issues like reverse power flow, overvoltage, harmonic current injection in the low-voltage (LV) network. In this paper, a realistic LV electric distribution network in the Kalmunai area, which is operated by the main utility provider in Sri Lanka, is modeled in ETAP software. The impact of PV penetration on transformer’s loading, power factor, power flow, power losses, and voltage profile of LV feeders are plotted and analyzed. Furthermore, the analysis is extended by considering various irradiance levels for different PV penetrations. Subsequently, the variation of voltage profile for solar PV concentrated feeder is plotted under various irradiance levels for different PV penetrations. The results indicate that overvoltage condition occurs at concentrated solar PV feeder, when the irradiance is high $\left(900 \mathrm{~W} / \mathrm{m}^{2}\right.$ and above), and the PV penetration is after the zero-crossing point. Additionally, the results show that reverse power flow occurs through the transformer when the aggregated solar PV active power generation exceeds the total active power demand of customers within the LV distribution network, which typically occurs during mid-day time (lower load demand time) when irradiance is higher ($\mathbf{9 0 0} \mathrm{W} / \mathrm{m}^{2}$ and above).

Integrity signals

Registry

Crossref · 10.1109/eecon64470.2024.10841870

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. 10.3390/en15239238 · DOI
  2. CEB Long Term Generation Expansion Plan 2023-2042
  3. 2023, CEB Distribution Construction Standards - Outdoor Distribution Substations
  4. 2022, Medium Voltage Distribution System Development Plan Distribution Division-02 2021-2028

Cited by

Still being checked.

Authors
Ilahi, A. S. A. M., Zeeminnaj, M. R., Ahamed, M. H. F., & Juhaniya, A. I. S.
Affiliations
South Eastern University of Sri Lanka (LK)
Venue
2024 4th International Conference on Electrical Engineering (EECon)
Publisher
IEEE
Published
2024-12-12
Pages
7-12
OpenAlex
W4406522643
Cited by
1
References
10
Citations by year
2026: 1
FWCI
0.81
Type
conference paper
Language
en
Open access
closed
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
Keywords
photovoltaic penetration, low-voltage distribution networks, reverse power flow, overvoltage, voltage profile, transformer loading, power losses, power factor, irradiance level, distributed energy resources

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›