Evaluation of novel algorithm embedded in a wearable sEMG device for seizure detection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We implemented a modified version of a previously published algorithm for detection of generalized tonic-clonic seizures into a prototype wireless surface electromyography (sEMG) recording device. The method was modified to require minimum computational load, and two parameters were trained on prior sEMG data recorded with the device. Along with the normal sEMG recording, the device is able to set an alarm whenever the implemented algorithm detects a seizure. These alarms are annotated in the data file along with the signal. The device was tested at the Epilepsy Monitoring Unit (EMU) at the Danish Epilepsy Center. Five patients were included in the study and two of them had generalized tonic-clonic seizures. All patients were monitored for 2-5 days. A double-blind study was made on the five patients. The overall result showed that the device detected four of seven seizures and had a false detection rate of 0.003/h or one in twelve days.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fisher, R. S., Boas, W. V. E., Blume, W., Elger, C., Genton, P., Lee, P., & Engel, J. (2005) · Epilepsia · doi:10.1111/j.0013-9580.2005.66104.x · Cited by 3,671
Cited by
Seizure detection, seizure prediction, and closed-loop warning systems in epilepsy
Ramgopal, S., Thome-Souza, S., Jackson, M., Kadish, N. E., Sánchez Fernández, I., Klehm, J., Bosl, W., Reinsberger, C., Schachter, S., & Loddenkemper, T. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.023 · Cited by 469
“[123] No Wireless surface electromyography (sEMG) http://ictalcare.”
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233
Automated real-time detection of tonic-clonic seizures using a wearable EMG device
Beniczky, S., Conradsen, I., Henning, O., Fabricius, M., & Wolf, P. (2018) · Neurology · doi:10.1212/wnl.0000000000004893 · Cited by 171
“A pilot study showed promising results for a wearable EMGbased device implementing our algorithm.(19)”
MethodSelf-citationHubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Self-citation
Metadata
- Authors
- Conradsen, I., Beniczky, S., Wolf, P., Jennum, P., & Sorensen, H. B. D.
- Venue
- 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2012-08
- Volume
- 2012
- Pages
- 2048-2051
- OpenAlex
- W2027134530
- Cited by
- 57
- References
- 1
- FWCI
- 6.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.