Automated real-time detection of tonic-clonic seizures using a wearable EMG device
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) using a wearable surface EMG device. METHODS: We prospectively tested the technical performance and diagnostic accuracy of real-time seizure detection using a wearable surface EMG device. The seizure detection algorithm and the cutoff values were prespecified. A total of 71 patients, referred to long-term video-EEG monitoring, on suspicion of GTCS, were recruited in 3 centers. Seizure detection was real-time and fully automated. The reference standard was the evaluation of video-EEG recordings by trained experts, who were blinded to data from the device. Reading the seizure logs from the device was done blinded to all other data. RESULTS: The mean recording time per patient was 53.18 hours. Total recording time was 3735.5 hours, and device deficiency time was 193 hours (4.9% of the total time the device was turned on). No adverse events occurred. The sensitivity of the wearable device was 93.8% (30 out of 32 GTCS were detected). Median seizure detection latency was 9 seconds (range -4 to 48 seconds). False alarm rate was 0.67/d. CONCLUSIONS: The performance of the wearable EMG device fulfilled the requirements of patients: it detected GTCS with a sensitivity exceeding 90% and detection latency within 30 seconds. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that for people with a history of GTCS, a wearable EMG device accurately detects GTCS (sensitivity 93.8%, false alarm rate 0.67/d).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660 · cited 1×
“We report our findings according to the Standards for Reporting of Diagnostic Accuracy (STARD) criteria.(20)”
MethodSudden unexpected death in epilepsy: epidemiology, mechanisms, and prevention
Devinsky, O., Hesdorffer, D. C., Thurman, D. J., Lhatoo, S., & Richerson, G. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(16)30158-2 · Cited by 721 · cited 1×
“Generalized tonic-clonic seizures (GTCS) may lead to injuries, and constitute the major risk factor for sudden unexpected death in epilepsy (SUDEP), especially in unattended patients.(1,2) Wearable seizure detection devices were suggested to prevent SUDEP.”
BackgroundAn introduction to power and sample size estimation
Jones, S. R., Carley, S., & Harrison, M. (2003) · Emergency Medicine Journal · doi:10.1136/emj.20.5.453 · Cited by 643 · cited 1×
“Sample size estimation For the expected sensitivity of 95%(17,19) and expected prevalence of 28% in the studied population,(22) with a confidence interval (CI) of 10%, we needed 18 patients with GTCS and 65 recruited patients.(23) GTCS is the seizure type with the highest risk for the patients and therefore considered…”
BackgroundBlum, D. E., Eskola, J., Bortz, J. J., & Fisher, R. S. (1996) · Neurology · doi:10.1212/wnl.47.1.260 · Cited by 281 · cited 2×
“Nevertheless, the baseline seizure frequency of GTCS was derived from the patients’ seizure logs, and previous studies showed that many GTCS remain undetected by the patients.(11)”
BackgroundResultBeniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230
Self-citationDetection of seizure-like movements using a wrist accelerometer
Lockman, J., Fisher, R. S., & Olson, D. M. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.01.019 · Cited by 195
Views of patients with epilepsy on seizure prediction devices
Schulze‐Bonhage, A., Sales, F., Wagner, K., Teotónio, R., Carius, A., Schelle, A., & Ihle, M. (2010) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2010.05.008 · Cited by 155
Non-EEG seizure detection systems and potential SUDEP prevention: State of the art
de Vel, A. V., Cuppens, K., Bonroy, B., Milošević, M., Jansen, K., Huffel, S. V., Vanrumste, B., Cras, P. P., Lagae, L., & Ceulemans, B. (2016) · Seizure · doi:10.1016/j.seizure.2016.07.012 · Cited by 139 · cited 1×
“The unpredictability of seizure occurrence is distressing for patients and caregivers.(3) It contributes to social isolation and decreased quality of life, and surveys showed a need for wearable seizure detection devices.”
BackgroundTomson, T., Surges, R., Delamont, R. S., Haywood, S., & Hesdorffer, D. C. (2016) · Epilepsia · doi:10.1111/epi.13234 · Cited by 132
A Novel Portable Seizure Detection Alarm System: Preliminary Results
Kramer, U., Kipervasser, S., Shlitner, A., & Kuzniecky, R. (2011) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3182051320 · Cited by 122 · cited 1×
“Another algorithm correctly identified 20 of 22 (91%) seizures from 15 patients, and had a detection latency of 17 seconds.(25) Although real-time, the analysis was done on a computer placed within 10meters from the patient.”
Background
Cited by
Machine learning and wearable devices of the future
Beniczky, S., Karoly, P., Nurse, E., Ryvlin, P., & Cook, M. (2021) · Epilepsia · doi:10.1111/epi.16555 · Cited by 155
Self-citationSeizure detection using wearable sensors and machine learning: Setting a benchmark
Tang, J., El Atrache, R., Yu, S., Asif, U., Jackson, M., Roy, S., Mirmomeni, M., Cantley, S., Sheehan, T., Schubach, S., et al. (2021) · Epilepsia · doi:10.1111/epi.16967 · Cited by 146
Signal quality and patient experience with wearable devices for epilepsy management
Nasseri, M., Nurse, E., Glasstetter, M., Böttcher, S., Gregg, N. M., Laks Nandakumar, A., Joseph, B., Pal Attia, T., Viana, P. F., Bruno, E., et al. (2020) · Epilepsia · doi:10.1111/epi.16527 · Cited by 90
Böttcher, S., Bruno, E., Manyakov, N. V., Epitashvili, N., Claes, K., Glasstetter, M., Thorpe, S., Lees, S., Dümpelmann, M., Van Laerhoven, K., et al. (2021) · JMIR mHealth and uHealth · doi:10.2196/27674 · Cited by 39
“Finally, electromyography is a self-evident modality for detecting seizures with motor components, identifying ictal muscle contraction, and thus has been used for convulsive seizure detection as well [25-28].”
MethodHubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Self-citation
Metadata
- Authors
- Beniczky, S., Conradsen, I., Henning, O., Fabricius, M., & Wolf, P.
- Venue
- Neurology
- Published
- 2018-01-30
- Volume
- 90
- Issue
- 5
- Pages
- e428-e434
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2781556396
- Cited by
- 171
- References
- 25
- FWCI
- 13.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated real-time detection of tonic-clonic seizures using a wearable EMG device. https://app.cochat.ai/papers/10.1212/wnl.0000000000004893
- The paper
- Beniczky, S., Conradsen, I., Henning, O., Fabricius, M., & Wolf, P. (2018). Automated real-time detection of tonic-clonic seizures using a wearable EMG device. Neurology. https://doi.org/10.1212/wnl.0000000000004893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.