Real-time ECG monitoring and arrhythmia detection using Android-based mobile devices
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We developed an application for Android™-based mobile devices that allows real-time electrocardiogram (ECG) monitoring and automated arrhythmia detection by analyzing ECG parameters. ECG data provided by pre-recorded files or acquired live by accessing a Shimmer™ sensor node via Bluetooth™ can be processed and evaluated. The application is based on the Pan-Tompkins algorithm for QRS-detection and contains further algorithm blocks to detect abnormal heartbeats. The algorithm was validated using the MIT-BIH Arrhythmia and MIT-BIH Supraventricular Arrhythmia databases. More than 99% of all QRS complexes were detected correctly by the algorithm. Overall sensitivity for abnormal beat detection was 89.5% with a specificity of 80.6%. The application is available for download and may be used for real-time ECG-monitoring on mobile devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 3×
“Furthermore, the width of detected QRS complexes QRSwidth was computed using the Pan-Tompkins integrator output [8].”
MethodThe impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812 · cited 2×
“Thirdly, we conduct a detailed evaluation of the application and the implemented algorithms in respect to QRS detection and abnormal beat classification using pre-recorded data of the MIT-BIH Arrhythmia [9] and MIT-BIH Supraventricular Arrhythmia [10]”
MethodPhysiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452 · cited 1×
“Scully et al. [7] demonstrated that physiological features like heart rate, breathing rate and blood-oxygen saturation can be extracted using camera recordings from mobile phones.”
BackgroundSilva, I., Moody, G. B., & Celi, L. A. (2011) · Cited by 125
QRS Template Matching for Recognition of Ventricular Ectopic Beats
Krasteva, V., & Jekova, I. I. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9368-9 · Cited by 87 · cited 6×
“As a fully autonomous approach was desired, these templates were not selected by a supervising cardiologist like in [1], but derived automatically from the ECG signal and adapted over time.”
BackgroundMethodInfluentialEskofier, B. M., Kugler, P., Melzer, D., & Kühner, P. (2012) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2012.4 · Cited by 25 · cited 1×
“Recently, such mobile devices are also used for biomedical signal processing and ECG analysis [3], [4], [5].”
BackgroundSelf-citationClassification of perceived running fatigue in digital sports
Eskofier, B. M., Hoenig, F., & Kühner, P. (2008) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2008.4761204 · Cited by 14 · cited 1×
“Recently, such mobile devices are also used for biomedical signal processing and ECG analysis [3], [4], [5].”
BackgroundSelf-citation
Cited by
Global epidemiology of atrial fibrillation
Rahman, F., Kwan, G. F., & Benjamin, E. J. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.118 · Cited by 731
An IoT-Based Computational Framework for Healthcare Monitoring in Mobile Environments
Mora, H., Gil, D., Terol, R. M., Azorín, J., & Szymanski, J. (2017) · Sensors · doi:10.3390/s17102302 · Cited by 168
“The design of the test is based on the results of previous research works [88,93,103,104] and on our own estimations.”
Method
Metadata
- Authors
- Gradl, S., Kugler, P., Lohmuller, C., & Eskofier, B.
- Venue
- 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2012-08
- Volume
- 2012
- Pages
- 2452-2455
- OpenAlex
- W2063875884
- Cited by
- 159
- References
- 8
- FWCI
- 40.83
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time ECG monitoring and arrhythmia detection using Android-based mobile devices. https://app.cochat.ai/papers/10.1109/embc.2012.6346460
- The paper
- Gradl, S., Kugler, P., Lohmuller, C., & Eskofier, B. (2012). Real-time ECG monitoring and arrhythmia detection using Android-based mobile devices. 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2012.6346460
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.