CoChat

Combined analysis of sensor data from hand and gait motor function improves automatic recognition of Parkinson's disease

Barth, J., Sunkel, M., Bergner, K., Schickhuber, G., Winkler, J., Klucken, J., Eskofier, B. · 2012 · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 43

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective and rater independent analysis of movement impairment is one of the most challenging tasks in medical engineering. Especially assessment of motor symptoms defines the clinical diagnosis in Parkinson's disease (PD). A sensor-based system to measure the movement of the upper and lower extremities would therefore complement the clinical evaluation of PD. In this study two different sensor-based systems were combined to assess movement of 18 PD patients and 17 healthy controls. First, hand motor function was evaluated using a sensor pen with integrated accelerometers and pressure sensors, and second, gait function was assessed using a sports shoe with attached inertial sensors (gyroscopes,accelerometers).Subjects performed standardized tests for both extremities.Features were calculated from sensor signals to differentiate between patients and controls. For the latter, pattern recognition methods were used and the performance of four classifiers was compared. In a first step classification was done for every single system and in a second step for combined features of both systems. Combination of both motor task assessments substantially improved classification rates to 97%using the AdaBoost classifier for the experiment patients vs.controls.The combination of two different analysis systems led to enhanced, more stable, objective, and rater independent recognition of motor impairment. The method can be used as a complementary diagnostic tool for movement disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/embc.2012.6347146

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 43

Metadata

Authors
Barth, J., Sunkel, M., Bergner, K., Schickhuber, G., Winkler, J., Klucken, J., & Eskofier, B.
Venue
2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2012-08
Volume
2012
Pages
5122-5125
OpenAlex
W2037810867
Cited by
43
References
3
FWCI
2.05
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combined analysis of sensor data from hand and gait motor function improves automatic recognition of Parkinson's disease. https://app.cochat.ai/papers/10.1109/embc.2012.6347146
The paper
Barth, J., Sunkel, M., Bergner, K., Schickhuber, G., Winkler, J., Klucken, J., & Eskofier, B. (2012). Combined analysis of sensor data from hand and gait motor function improves automatic recognition of Parkinson's disease. 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2012.6347146

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.