Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion
Open accessAbstract
Reflection photoplethysmography (PPG) using 530 nm (green) wavelength light has the potential to be a superior method for monitoring heart rate (HR) during normal daily life due to its relative freedom from artifacts. However, little is known about the accuracy of pulse rate (PR) measured by 530 nm light PPG during motion. Therefore, we compared the HR measured by electrocadiography (ECG) as a reference with PR measured by 530, 645 (red), and 470 nm (blue) wavelength light PPG during baseline and while performing hand waving in 12 participants. In addition, we examined the change of signal-to-noise ratio (SNR) by motion for each of the three wavelengths used for the PPG. The results showed that the limit of agreement in Bland-Altman plots between the HR measured by ECG and PR measured by 530 nm light PPG (±0.61 bpm) was smaller than that achieved when using 645 and 470 nm light PPG (±3.20 bpm and ±2.23 bpm, respectively). The ΔSNR (the difference between baseline and task values) of 530 and 470nm light PPG was significantly smaller than ΔSNR for red light PPG. In conclusion, 530 nm light PPG could be a more suitable method than 645 and 470nm light PPG for monitoring HR in normal daily life.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ambient artifacts are for example light artifacts interfering with the light of the PPG sensor43, weather conditions, such as high humidity which increases the moisture level of the skin surface and thus its conductivity44, as well as coverage of the device for example by a blanket which increases the temperature and thereby potentially EDA levels45.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [43]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9505-0 · Cited by 203
Reddy, K. A., George, B., & Kumar, V. J. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2009136 · Cited by 165
In vivo reflectance of blood and tissue as a function of light wavelength
Cui, W., Ostrander, L. E., & Lee, B. Y. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55667 · Cited by 149
Spīgulis, J., Gailite, L., Lihachev, A., & Erts, R. (2007) · Applied Optics · doi:10.1364/ao.46.001754 · Cited by 98
Han, H., & Kim, J. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.12.005 · Cited by 92
Matsumura, K., & Yamakoshi, T. (2013) · Behavior Research Methods · doi:10.3758/s13428-012-0312-z · Cited by 87
Self-citationPulsed multifrequency photoplethysmograph
Giltvedt, J., Sira, A., & Helme, P. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442745 · Cited by 47
Research works printed but not linked: 1
- challoner, 1979, Photoelectric plethysmography for estimating cutaneous blood flow, Noninvasive Physiological Measurements, 1, 125
Cited by
Sorted by citations
Items 101–200 of 201
A Wearable Wireless Medical Sensor Network System Towards Internet-of-Patients
Wu, T., Redouté, J., & Yuce, M. R. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589642 · Cited by 12
Yeo, H.-S., Feng, W., & Huang, M. X. (2020) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3313831.3376198 · Cited by 11
Liu, Y., Guo, X., & Zhang, Y. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105461 · Cited by 10
Novel Continuous Respiratory Rate Monitoring Using an Armband Wearable Sensor
Huang, N., Zhou, M., Bian, D., Mehta, P., Shah, M., Rajput, K. S., & Selvaraj, N. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630025 · Cited by 10
Abe, M., Yoshizawa, M., Obara, K., Sugita, N., Homma, N., & Yambe, T. (2015) · Advanced Biomedical Engineering · doi:10.14326/abe.4.1 · Cited by 10
Heart rate monitoring by using non-invasive wearable sensor
Maria, A. R., Pasca, S., & Strungaru, R. (2017) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb.2017.7995492 · Cited by 10
An Exploration of Blue PPG Signal Using a Novel Color Sensorbased PPG System
Shchelkanova, E., Shchelkanov, A., Shchapova, L., & Shibata, T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175745 · Cited by 10
Criterion validity and accuracy of a heart rate monitor
Damasceno, V. D. O., Costa, A. D. S., Campello, M. C. A., de Souza, D. E., Gonçalves, R., Campos, E. Z., & Santos, T. M. (2021) · Human Movement · doi:10.5114/hm.2021.104188 · Cited by 10
Acevedo, R. U., Sánchez, L. O., Londoño, S. V., Mejía‐Mejía, E., Villa, R. T., & Montoya, Y. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.1.017001 · Cited by 9
Raw Photoplethysmography as an Enhancement for Research-Grade Wearable Activity Monitors
Hibbing, P. R., & Khan, M. M. (2024) · JMIR mhealth and uhealth · doi:10.2196/57158 · Cited by 10
Liu, I., Liu, F., Zhong, Q., & Ni, S. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01365-w · Cited by 13
Cause, J. L., Morillo, Á. S., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2023) · Sensors · doi:10.3390/s23146628 · Cited by 9
Capturing the pulse: a state-of-the-art review on camera-based jugular vein assessment
Arrow, C., Ward, M., Eshraghian, J. K., & Dwivedi, G. (2023) · Biomedical Optics Express · doi:10.1364/boe.507418 · Cited by 9
Multi-wavelength SPAD photoplethysmography for cardio-respiratory monitoring
Cusini, I., Rinaldi, R., Castiglioni, P., Faini, A., & Villa, F. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.952103 · Cited by 8
Mascret, Q., Gurve, D., Abdou, A., Bhadra, S., Lasry, N., Mai, K., Krishnan, S., & Gosselin, B. J. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3388950 · Cited by 8
Exploring the Usage of Time-of-Flight Cameras for Contact and Remote Photoplethysmography
Nahler, C., Feldhofer, B., Rüther, M., Holweg, G., & Druml, N. (2018) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2018.00079 · Cited by 8
Semeraro, F., Fiorini, L., Betti, S., Mancioppi, G., Santarelli, L., & Cavallo, F. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-3-030-05921-7_30 · Cited by 8
Yan, L., Long, Z., Qian, J., Lin, J., Xie, S. Q., & Sheng, B. (2024) · Sensors · doi:10.3390/s24092925 · Cited by 9
Data-Driven Decision Support for Equipment Selection and Maintenance Issues for Buildings
Feng-chang, J., Xie, H. S., Inti, S., Issa, R. R. A., Vanka, V. S. V., Yu, Y., & Huang, T. (2024) · Buildings · doi:10.3390/buildings14020436 · Cited by 7
A Wireless Low-Power Single-Unit Wearable System for Continuous Early Warning Score Calculation
Bellier, P., Wallant, D. C. ’., van den Bongarth, H., Bijnens, W., Aarts, J., Vandenryt, T., Thoelen, R., Duflot, P., Dupont, F., & Redouté, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3267146 · Cited by 8
Automated myocardial infarction and angina detection using second derivative of photoplethysmography
Neha, N., Sardana, H. K., Dahiya, N., Dogra, N., Kanawade, R. V., Sharma, Y. P., & Kumar, S. (2023) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-023-01293-w · Cited by 6
High performance WSe2 and CuO heterojunction based photodetector for wearable devices
Bajpai, T., Dwivedi, A. K., Nagaria, R. K., & Tripathi, S. (2023) · Optical Materials · doi:10.1016/j.optmat.2023.114230 · Cited by 6
Wang, Y., Ren, Y. Y., Wang, T., Li, D., Cai, H., & Ji, B. (2024) · Journal of Biophotonics · doi:10.1002/jbio.202400119 · Cited by 6
Wearable heart rate monitor using photoplethysmography for motion
Sudin, S., Aziz, F., Hishamuddin, N. A., Saad, F. S. A., Shakaff, A. Y. M., Zakaria, A., & Salleh, A. F. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047462 · Cited by 6
Evaluation of a strapless heart rate monitor during simulated flight tasks
Wang, Z., & Fu, S. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1101121 · Cited by 6
Pulse rate variability analysis by video using face detection and tracking algorithms
Rodríguez, A., & Ramos-Castro, J. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319685 · Cited by 7
Heart-rate modulation of non-vascularized epidermis optical attenuation coefficient
Martinelli, M. B., Dominguez, C. T., Bachmann, L., & Cardoso, G. C. (2019) · Dynamics and Fluctuations in Biomedical Photonics · doi:10.1117/12.2508882 · Cited by 6
A personalized on-line calibration for photoplethysmograph based wrist wearable sensor
Ahmed, N., Chowdhury, A., Sinharay, A., Mukhopadhyay, S., Ghose, A., & Chakravarty, T. (2017) · Global Wireless Summit (GWS) · doi:10.1109/gws.2017.8300498 · Cited by 5
Monitoring the Welfare of Bears in Captivity
Byrne, C., Karl, S., Vilker, D. B., Meller, S., Thompson, B., & Webber, S. E. (2020) · International Conference on Animal-Computer Interaction (ACI) · doi:10.1145/3446002.3446053 · Cited by 5
Baciu, V.-E., Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2023) · Sensors · doi:10.3390/s23156947 · Cited by 5
Li, K., & Sun, J. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad6be4 · Cited by 5
Bhutta, M. A. M., Kim, S., & Kim, Y. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3544290 · Cited by 5
Lee, H., Ko, H., Thap, T., & Lee, J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591457 · Cited by 5
Self-citationWei, B., Zhang, C., & Wu, X. (2016) · doi:10.1145/3028842.3028890 · Cited by 5
Shchelkanova, E., Shchapova, L., Shchelkanov, A., & Shibata, T. (2021) · Sensors · doi:10.3390/s21124241 · Cited by 6
HANDIO: A Wireless Hand Gesture Recognizer Based on Muscle-Tension and Inertial Sensing
Luan, J., Chien, T.-C., Lee, S., & Chou, P. H. (2014) · Globecom · doi:10.1109/glocom.2015.7417448 · Cited by 5
Regalia, G., Resnati, D., & Tognetti, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00130-8 · Cited by 9
Le, V. N. D., Fronckowiak, S., & Badolato, E. (2025) · Sensors · doi:10.3390/s25072311 · Cited by 5
Model-based estimation of heart movements using microwave Doppler radar sensor
Ota, T., & Okusa, K. (2024) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.1186/s40101-024-00373-4 · Cited by 4
Preliminary Evaluation of an Injectable Sensor for Subcutaneous Photoplethysmography in Animals
Reynolds, J., Ahmmed, P., & Bozkurt, A. Y. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584775 · Cited by 4
A Novel Photoplethysmographic Noise Removal Method via Wavelet Transform to Effective preprocessing
Georgieva-Tsaneva, G. N. (2022) · International Conference on Computer Systems and Technologies (CompSysTech) · doi:10.1145/3546118.3546145 · Cited by 4
Pulse Rate Guided Oxygen Saturation Monitoring Using a Wearable Armband Sensor
Huang, N., Bian, D., Zhou, M., Mehta, P., Shah, M., Rajput, K. S., Majmudar, M. D., & Selvaraj, N. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871461 · Cited by 4
Arterial pulsation modulates the optical attenuation coefficient of skin
Dominguez, C. T., Martinelli, M. B., Bachmann, L., & Cardoso, G. C. (2023) · Journal of the Optical Society of America A · doi:10.1364/josaa.482939 · Cited by 4
Smartphone Based BP Level Monitoring System Using DNN Model
Mahmuda, Barkatullah, Haque, M. R., Noman, A. A., Haque, E., & Ahmed, F. (2023) · International Conference on Advanced Technologies for Communications · doi:10.1109/atc58710.2023.10318933 · Cited by 4
Development of a bluetooth 4.0 PPG sensor for use in Heart Rate Variability analysis
Blake, M. (2015) · International Conference on Consumer Electronics · doi:10.1109/icce.2015.7066423 · Cited by 4
Real-time heart activity monitoring with optical illusion using a smartphone
Thap, T., Chung, H., Jeong, C., Ryu, J., Nam, Y., Yoon, K., & Lee, J. (2017) · Multimedia Tools and Applications · doi:10.1007/s11042-017-4530-3 · Cited by 4
Self-citationHeart Rate Monitoring Using a Slow–Fast Adaptive Comb Filter to Eliminate Motion Artifacts
Chuang, C.-T., Chang, T., Chiang, Y.-T., & Chang, F. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0183-3 · Cited by 4
Wearable oximetry for harsh environments
Telfer, B. A., Hoyt, R. W., Lacirignola, J. J., Patel, T., Siegel, A. M., Swiston, A. J., Singh, N., Trebicka, R., Weston, C., & Williamson, J. R. (2017) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2017.7936019 · Cited by 4
Fast And Robust Heart Rate Estimation From Videos Through Dynamic Region Selection
Fujita, Y., Hiromoto, M., & Sato, T. G. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513020 · Cited by 4
Branan, K. L., Kurian, R., McMurray, J. P., Erraguntla, M., Gutiérrez‐Osuna, R., & Coté, G. L. (2025) · Biosensors · doi:10.3390/bios15080493 · Cited by 4
Track Cyclist Performance Monitoring System Using Wireless Sensor Network
Sudin, S., Shakaff, A. Y. M., Aziz, F., Saad, F. S. A., Zakaria, A., & Salleh, A. F. (2016) · Springer eBooks · doi:10.1007/978-981-10-0534-3_12 · Cited by 3
Development and Testing of a Miniaturized Platform for Photoplethysmography
Traversi, G., Gaioni, L., & Salvetti, D. (2023) · Electronics · doi:10.3390/electronics12102230 · Cited by 3
Energy-Efficient Spectral Analysis of ECGs on Resource Constrained IoT Devices
Eleftheriadis, C., & Karakonstantis, G. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3406520 · Cited by 4
Fawcett, A. (2018) · UWSpace (University of Waterloo) · Cited by 3
Reduction of Motion Artifact in PPG signal with CDS-LMS Filter
Lee, W., Park, P., & Cho, S. (2022) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas55924.2022.10090402 · Cited by 2
A Wearable Solution for Obstructive Sleep Apnea Risk Evaluation Based on Optical Sensor
Wang, C. H., Lu, S. J., Chou, Y. M., Kao, C. Y., & Lin, H. Y. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325053 · Cited by 2
Borik, Š., Wu, H., Shelley, K. H., & Alian, A. A. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106574 · Cited by 2
Miyaji, T., Sviridova, N., Aihara, K., Zhao, T., & Nakano, A. (2019) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.5088989 · Cited by 2
Efficient detection of eye blinking and yawn based on facial video utilizing IPPG technique
Wei, B., Lu, X., Zhang, C., & Wu, X. (2017) · International Forum on Mechanical, Control and Automation (IFMCA) · doi:10.2991/ifmca-16.2017.26 · Cited by 2
Multi-modal physiological sensing on the upper arm
Branan, K. L., Reyes, G. O. F., Abel, J. A., Erraguntla, M., Gutiérrez‐Osuna, R., & Coté, G. L. (2022) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.2606468 · Cited by 2
Signal Quality Assessment for Wearable Multichannel Photoplethysmography Signals
Prihatmoko, M. D., Ahmadi, N., Charlton, P. H., & Adiono, T. (2023) · Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC) · doi:10.1109/apsipaasc58517.2023.10317377 · Cited by 2
Simulating cardiac signals on 3D human models for photoplethysmography development
Wang, D., & Chahl, J. (2024) · Frontiers in Robotics and AI · doi:10.3389/frobt.2023.1266535 · Cited by 2
Khatoun, A., Stuart, S., Petre, A.-R., Peeters, B., Soundararajan, A., Uzunbajakava, N. E., Zoutenbier, V. S., Akkerman, H. B., & Amelink, A. (2024) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.3002506 · Cited by 2
Monitoring Physiological Signals Using Camera
Shao, D. (2016) · Cited by 2
Cyclist Performance Classification System based on Submaximal Fitness Test
Sudin, S., Shakaff, A. Y. M., Zakaria, A., Salleh, A. F., Saad, F. S. A., & Abdullah, A. H. (2018) · Journal of Telecommunication Electronic and Computer Engineering (JTEC) · Cited by 2
Analysing the Performance of Blood Pressure Parameters Using EMF Method
Subramani, S., Sukumar, S., Ahmed, Z., Venkat, V., Sriram, V., & Geethanjali, B. (2020) · International Conference on Trends in Electronics and Informatics (ICOEI) · doi:10.1109/icoei48184.2020.9142931 · Cited by 1
Prototype Smart Home Environment with Biofeedback
Kalam, A. M., Azad, M., & Chowdhury, S. J. (2020) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp50017.2020.9230898 · Cited by 1
Peripheral Oxygen Saturation Measurement: Could the Wrist be an Alternative Site for a Finger?
Devaki, V., Lakshmanan, M. K., & Jayanthi, T. (2023) · IEEE World Conference on Applied Intelligence and Computing (AIC) · doi:10.1109/aic57670.2023.10263821 · Cited by 1
Śmigielski, B. T., Chołuj, M. N., & Cybulski, G. (2024) · Acta Physica Polonica A · doi:10.12693/aphyspola.146.600 · Cited by 1
Design of Wearable System for Detection and Analysis of Physiological Information
Shi, P. A., Xu, Y., & Yu, H. (2017) · International Conference on Intelligent Human-Machine Systems and Cybernetics · doi:10.1109/ihmsc.2017.51 · Cited by 1
Villa, A. D. (2021) · IEEE International Symposium on Electronics and the Environment (ISEE) · doi:10.1109/isee51682.2021.9418794 · Cited by 1
Valenti, S., Volpes, G., Parisi, A., Pernice, R., Stivala, S. S., Faes, L., & Busacca, A. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856478 · Cited by 1
Maldonado, D. L., Leslie, G. A., Salazar-Torres, J. A., Téllez-Anguiano, A. D. C., & Fraga-Aguilar, M. (2022) · IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC) · doi:10.1109/ropec55836.2022.10018715 · Cited by 1
Wang, L., Tao, X., Sun, L., & Shen, W. (2024) · SpringerBriefs in computer science · doi:10.1007/978-981-97-4550-0_4 · Cited by 1
Heart rate compression & time reduction method for HRV monitoring in athletes
Darabi, S., Moatamed, B., Huang, W., Gwak, M., Metoyer, C. J., Linn, M., & Sarrafzadeh, M. (2017) · IEEE Healthcare Innovations and Point of Care Technologies Conference (HI-POCT) · doi:10.1109/hic.2017.8227607 · Cited by 1
Królak, A., & Biskupiak, J. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-29885-2_1 · Cited by 1
Effect of defocus blur on the signal distribution of camera-based remote photoplethysmography
Yang, S., Zhu, Y., & He, S. (2019) · Optoelectronic Imaging and Multimedia Technology · doi:10.1117/12.2536628 · Cited by 1
Optical difference in the frequency domain to suppress disturbance for wearable electronics
Li, H., Wang, Z., Cao, Y. K., Ma, Y., & Feng, X. (2020) · Biomedical Optics Express · doi:10.1364/boe.403033 · Cited by 1
Wearable Sensors and Deep Learning for the Management of Acute Pancreatitis in Precision Medicine
Liu, Q., Jiang, Y., Yu, R., & Poon, C. C. Y. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00068-6 · Cited by 2
The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light
Chang, K. Y., Ko, H., Lee, J. J., & Yoon, Y. R. (2014) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2014.35.5.125
Self-citationAlzahrani, A., Hu, S., Azorin-Peris, V., Barrett, L. A., Esliger, D., Hayes, M., Akbare, S., Achart, J., & Kuoch, S. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2076582
Fall detectors for people with dementia
Leake, J. (2015) · The University of Bath Online Publications Store (The University of Bath)
Development of a simulation tool for optimal design of a mobile photoplethysmography sensor
Fedorin, I. V., Tuz, V. R., Gryshchenko, S. V., Choi, J. M., & Chung, S. H. (2017) · IEEE Ukraine Conference on Electrical and Computer Engineering (UKRCON) · doi:10.1109/ukrcon.2017.8100500
Blood pressure estimation based on pulse transit time with LANDMARC
Wang, Y., & Liu, Z. (2017) · IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268163
A New Look at the Essence of the Array Photoplethysmograph
Han, W., Chou, Y. M., Chuang, C. Y., Wu, C. Y., & Huang, S. H. (2019) · International Conference on Biomedical Engineering and Technology (ICBET) · doi:10.1145/3326172.3326187
Gryshchenko, S. V., Fedorin, I. V., & Аврунін, О. (2019) · CAOL . International Conference on Advanced Optoelectronics and Lasers · doi:10.1109/caol46282.2019.9019462
Wearable Continuous Blood Pressure Estimation with Photoplethysmography Sensors Array on the Arm
Qiu, C., Wu, T., Redouté, J., & Yuce, M. R. (2020) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-29897-5_24
Sharma, A., Law, C. G., Lo, C. W., Ovia, J., Hia, M., Phongsopa, P., Horder, R., & Tang, R. (2021) · Research Square · doi:10.21203/rs.3.rs-558586/v1
Smartphone IoT-Based Point of Care Method for Arrhythmia Detection
Boggs, A., Chapman, H., & Askarian, B. (2022) · IEEE Healthcare Innovations and Point of Care Technologies Conference (HI-POCT) · doi:10.1109/hi-poct54491.2022.9744077
Ceugniez, M., Devanne, H., & Hermand, É. (2023) · doi:10.2196/preprints.54871
Research on Non-Contact Heart Rate Detection Based on Multi-Spectral Imaging Technology
王, 禹. (2024) · Applied Physics · doi:10.12677/app.2024.143015
Green-Infrared Dominance in Atrial Fibrillation Detection
Devaki, V. (2024) · African Journal of Biomedical Research · doi:10.53555/ajbr.v27i4s.5498
A Sensor-Based System for Cardiac Activity Tracking with Integrated Remote Monitoring Capabilities
Georgieva-Tsaneva, G. N., & Cheshmedzhiev, K. (2025) · International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) · doi:10.1109/ismsit67332.2025.11268023
Taranum, F., Kauser, S., Hijab, M., Patil, M. G., & Sayeedunnisa, S. F. (2026) · Advances in Science Technology and Engineering Systems Journal · doi:10.25046/aj110104
Wang, L., Liu, J., Wang, S. Q., Li, Y., Cui, J., Liu, Y., Liao, P., Li, J. S., Tian, M., & Wen, Q. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00616
Rojas‐Valverde, D., & Gamboa-Salas, J. C. (2026) · Revista de Ciencias del Ejercicio FOD · doi:10.29105/rce-fod.v21i2.184
Metadata
- Authors
- Lee, J., Matsumura, K., Yamakoshi, K.-I., Rolfe, P., Tanaka, S., & Yamakoshi, T.
- Affiliations
- Kanazawa University (JP)
- Harbin Institute of Technology (CN)
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Issue
- 6609852
- Pages
- 1724-1727
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W1988770599
- Cited by
- 202
- References
- 12
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 23 · 2023: 26 · 2022: 19 · 2021: 16 · 2020: 14 · 2019: 19 · 2018: 23 · 2017: 19 · 2016: 11 · 2015: 15 · 2014: 5
- FWCI
- 20.48
- Type
- conference paper
- Language
- en
- Open access
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
- Kanazawa University Repository for Academic Resources (DSpace) (Kanazawa University) (submittedVersion, cc-by-nc-nd)
- Funders
- Kissei
- Japan Society for the Promotion of Science (24650443)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart rate monitoring, motion artifacts, signal-to-noise ratio, hand waving, ECG comparison, wearable sensors, non-contact vital sign monitoring
- MeSH terms
- Adult, Heart Rate, Humans, Light, Male, Movement, Photoplethysmography, Monitoring, Ambulatory, Young Adult, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review