Highly wearable galvanic skin response sensor using flexible and conductive polymer foam
The DOI matches its Crossref record.
Abstract
Owing to advancements in daily physiological monitoring technology, diverse healthcare applications have emerged recently. The monitoring of skin conductance responses has extensive feasibility to support healthcare applications such as detecting emotion changes. In this study, we proposed a highly wearable and reliable galvanic skin response (GSR) sensor that measures the signals from the back of the user. To enhance its wearability and usability, we employed flexible conductive foam as the sensing material and designed it to be easily attachable to (and detachable from) a wide variety of clothes. We evaluated the sensing reliability of the proposed sensor by comparing its signal with a reference GSR. The average correlation between the two signals was 0.768; this is sufficiently high to validate the feasibility of the proposed sensor for reliable GSR sensing on the back.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“For example, skin perspiration and heart rate variability can be used to classify mental states, helping in the distinction, as also in the detection of mental stress [53,54].”
BackgroundInnovations in Electrodermal Activity Data Collection and Signal Processing: A Systematic Review
Posada-Quintero, H. F., & Chon, K. H. (2020) · Sensors · doi:10.3390/s20020479 · Cited by 525
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Jang, H., Sel, K., Kim, E., Kim, S., Yang, X., Kang, S., Ha, K.-H., Wang, R., Rao, Y., Jafari, R., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-34406-2 · Cited by 127
Metadata
- Authors
- Kim, J., Kwon, S., Seo, S., & Park, K.
- Venue
- 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2014-08
- Volume
- 2014
- Pages
- 6631-6634
- OpenAlex
- W2320459486
- Cited by
- 35
- References
- 0
- FWCI
- 2.57
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly wearable galvanic skin response sensor using flexible and conductive polymer foam. https://app.cochat.ai/papers/10.1109/embc.2014.6945148
- The paper
- Kim, J., Kwon, S., Seo, S., & Park, K. (2014). Highly wearable galvanic skin response sensor using flexible and conductive polymer foam. 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2014.6945148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.