TinySleepNet: An Efficient Deep Learning Model for Sleep Stage Scoring based on Raw Single-Channel EEG
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Deep learning has become popular for automatic sleep stage scoring due to its capability to extract useful features from raw signals. Most of the existing models, however, have been overengineered to consist of many layers or have introduced additional steps in the processing pipeline, such as converting signals to spectrogram-based images. They require to be trained on a large dataset to prevent the overfitting problem (but most of the sleep datasets contain a limited amount of class-imbalanced data) and are difficult to be applied (as there are many hyperparameters to be configured in the pipeline). In this paper, we propose an efficient deep learning model, named TinySleepNet, and a novel technique to effectively train the model end-to-end for automatic sleep stage scoring based on raw single-channel EEG. Our model consists of a less number of model parameters to be trained compared to the existing ones, requiring a less amount of training data and computational resources. Our training technique incorporates data augmentation that can make our model be more robust the shift along the time axis, and can prevent the model from remembering the sequence of sleep stages. We evaluated our model on seven public sleep datasets that have different characteristics in terms of scoring criteria and recording channels and environments. The results show that, with the same model architecture and the training parameters, our method achieves a similar (or better) performance compared to the state-of-the-art methods on all datasets. This demonstrates that our method can generalize well to the largest number of different datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Very Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148 · cited 1×
“This is motivated by the design patterns of VGGNet [10], in which a stack of conv layers has the same effective receptive fields as one conv layer with a lager filter.”
MethodGoldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Allan Hobson, J. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90021-2 · Cited by 5,192
Understanding deep learning requires rethinking generalization
Zhang, C., Bengio, S., Hardt, M., Recht, B., & Vinyals, O. (2016) · arXiv · doi:10.48550/arxiv.1611.03530 · Cited by 2,838 · cited 1×
“However, these models consist of too many layers and parameters that require to be trained on large sleep data to prevent the overfitting problem [8], in which most of the sleep datasets have only a limited amount of data.”
BackgroundDeepSleepNet: a model for automatic sleep stage scoring based on raw single-channel EEG
Supratak, A., Dong, H., Wu, C., & Guo, Y. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2721116 · Cited by 1,376 · cited 6×
“…a single-channel EEG epoch into a feature vector, and θ r is the learnable parameters of the CNNs. Note that the size of a i varies depending on the sampling rate of the input EEG. Unlike the previous work [5], we use only one branch of the CNNs, instead of two branches with small and large filters.”
BackgroundMethodResultInfluentialSelf-citationWhy Sleep Is Important for Health: A Psychoneuroimmunology Perspective
Irwin, M. R. (2015) · Annual Review of Psychology · doi:10.1146/annurev-psych-010213-115205 · Cited by 1,325 · cited 1×
“Polysomnography (PSG) is a sleep study to objectively assess the quality of sleep, which plays a vital role in promoting mental and physical health [1].”
BackgroundAnalysis of a sleep-dependent neuronal feedback loop: the slow-wave microcontinuity of the EEG
Kemp, B., Zwinderman, A. H., Tuk, B., Kamphuisen, H. A. C., & Oberye, J. J. L. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867928 · Cited by 953 · cited 1×
“We evaluated our model using seven public sleep datasets obtained from Montreal Archive of Sleep Studies (MASS) [11] and Sleep-EDF [12], [13].”
MethodThe AASM Manual for the Scoring of Sleep and Associated Events : Rules
Iber, C. (2007) · Medical Entomology and Zoology · Cited by 929
SleepEEGNet: Automated sleep stage scoring with sequence to sequence deep learning approach
Mousavi, S., Afghah, F., & Acharya, U. R. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216456 · Cited by 531 · cited 2×
“The numbers of parameters for DeepSleepNet [5] and SleepEEGNet [7] are ∼ 21m and ∼ 2.6m, which are approximately 15 and 2 times larger than our model ( ∼ 1.3m), respectively.”
BackgroundO'Reilly, C., Gosselin, N., Carrier, J., & Nielsen, T. (2014) · Journal of Sleep Research · doi:10.1111/jsr.12169 · Cited by 356 · cited 1×
“We evaluated our model using seven public sleep datasets obtained from Montreal Archive of Sleep Studies (MASS) [11] and Sleep-EDF [12], [13].”
MethodHow to interpret the results of a sleep study
Shrivastava, D., Jung, S., Saadat, M., Sirohi, R., & Crewson, K. (2014) · Journal of Community Hospital Internal Medicine Perspectives · doi:10.3402/jchimp.v4.24983 · Cited by 313 · cited 1×
“People with sleep disorders, such as sleep apnea, are diagnosed with PSG to evaluate the severity of their symptoms [2].”
BackgroundHassan, A. R., & Subasi, A. (2017) · Knowledge-Based Systems · doi:10.1016/j.knosys.2017.05.005 · Cited by 236 · cited 1×
“Also, Cohen’s Kappa shows that the agreement between our model and the sleep experts is almost perfect (0.81-1) or substantial (0.61-0.8) [15].”
BackgroundInfluentialTowards More Accurate Automatic Sleep Staging via Deep Transfer Learning
Phan, H., Chén, O. Y., Koch, P., Lu, Z., McLoughlin, I. V., Mertins, A., & Vos, M. D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3020381 · Cited by 179 · cited 3×
“Several studies have proposed to transform raw PSG epochs into spectral-based images, typically small ones, before training deep learning models [9].”
BackgroundMethodRecommendations for performance assessment of automatic sleep staging algorithms
Imtiaz, S. A., & Rodriguez–Villegas, E. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944758 · Cited by 36 · cited 1×
“If the datasets were scored according to the R&K manual, we converted them to be the same as the AASM manual by merging the N3 and N4 stages into a single stage N3 to facilitate comparison across datasets [14].”
MethodNumerical Verification of Affine Systems with up to a Billion DimensionsPreprint
Bak, S., Tran, H.-D., & Johnson, T. T. (2019) · EasyChair preprint · doi:10.29007/b8zr · Cited by 21
Cited by
Zhang, H., Wang, J., Xiao, Q., Deng, J., & Lin, Y. (2021) · arXiv · doi:10.48550/arxiv.2110.09966 · Cited by 4
“Thus, a branch of supervised approaches focus on single-channel EEG (Seifpour et al. 2018; Sors et al. 2018; Supratak and Guo 2020; Fu et al. 2021).”
Background
Metadata
- Authors
- Supratak, A., & Guo, Y.
- Venue
- 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2020-07
- Volume
- 2020
- Pages
- 641-644
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W3082394918
- Cited by
- 241
- References
- 15
- FWCI
- 33.68
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.