A three-phase 10 kVAC-750 VDC power electronic transformer for smart distribution grid
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this paper, a power electronic transformer (PET) topology for distribution grid is presented based on modular multilevel converter (MMC). The presented topology is of three-phase type and have two dc voltage terminals, i.e. the high-voltage dc terminal and the low-voltage dc terminal. So, it can be connected directly to high-voltage direct current (HVDC) systems and renewable energy systems simultaneously. This feature makes it possible to perform as an “energy router” in smart grids. What is more important, the proposed PET can substantially reduce (by 44.4% for the studied case) the number of medium frequency transformers (MFTs), compared with the existing solutions. Computer simulation and experimental results on a 10 kV prototype show validity of this PET.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, J., Huang, A., Sung, W., Liu, Y., & Baliga, B. (2009) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2009.932583 · Cited by 260 · cited 1×
“As the intelligence level of the electric devices will determine the fundamental and key functions of the future smart grid, the research and development of PETs have attracted much attention not only in research institutions but also in industries [1-12].”
BackgroundMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249
Multilevel Converter for Traction Applications: Small-Scale Prototype Tests Results
Carpita, M., Marchesoni, M., Pellerin, M., & Moser, D. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918645 · Cited by 100 · cited 4×
“So, the ISOP converter can balance the capacitor voltages on the HV DC side naturally without special control [5-7].”
BackgroundInfluential
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Hybrid-Frequency Cascaded Full-Bridge Solid-State Transformer
Zhang, X., Xu, Y., Long, Y., Xu, S., & Siddique, A. (2019) · IEEE Access · doi:10.1109/access.2019.2898985 · Cited by 45
“Furthermore, the HFT RMS current of the DC/AC converter in [18] is 365% of that of a two-stage DAB-based DC/AC converter [18] thereby greatly increases costs, since in MV applications, the costs of HFT is a large part of SST’s overall costs.”
BackgroundMethodInfluentialPower flow control scheme for multiport power electronics transformers
Zhang, H., Jing, L., Wu, X., Jiang, J., Wickramasinghe, H. R., & Konstantinou, G. (2018) · High Voltage · doi:10.1049/hve.2018.5034 · Cited by 8
Metadata
- Authors
- Li, Z., Wang, P., Chu, Z., Zhu, H., Sun, Z., & Li, Y.
- Venue
- 2013 15th European Conference on Power Electronics and Applications (EPE)
- Publisher
- IEEE
- Published
- 2013-09
- Pages
- 1-9
- OpenAlex
- W1964394431
- Cited by
- 87
- References
- 3
- FWCI
- 4.07
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A three-phase 10 kVAC-750 VDC power electronic transformer for smart distribution grid. https://app.cochat.ai/papers/10.1109/epe.2013.6631810
- The paper
- Li, Z., Wang, P., Chu, Z., Zhu, H., Sun, Z., & Li, Y. (2013). A three-phase 10 kVAC-750 VDC power electronic transformer for smart distribution grid. 2013 15th European Conference on Power Electronics and Applications (EPE). https://doi.org/10.1109/epe.2013.6631810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.