The DOI matches its Crossref record.
Virtual synchronous machine
Abstract
Demands in the area of electrical energy generation and distribution, as a result of energy policies, are leading to far reaching changes in the structure of the energy supply, which is characterised, on the one hand, by the substitution of conventional power stations by renewable energy generation, a decision which has already been made, and, on the other hand, by the changeover from centralised to decentralised energy generation. From an electrical engineering point of view, a new situation will arise for consumers concerning security of supply and power quality, which calls for further technical measures by the grid operators to ensure that the increasingly stringent supply criteria can be met. This article describes a new power electronics based approach which allows a grid compatible integration of predominantly renewable electricity generators even in weak grids making them appear to be electromechanical synchronous machines. As a consequence, all the proven properties of this type of machine which have so far defined the grid continue to do so, even when integrating photovoltaic or wind energy. These properties include, for instance, interaction between grid and generator as in a remote power dispatch, reaction to transients as well as the full electrical effects of a rotating mass. In addition, this new development can be operated in such a way that it provides primary reserve allowing, from a grid point of view, electricity generators such as wind and PV to be regarded as conventional power stations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Improvement of Frequency Regulation in VSG-Based AC Microgrid Via Adaptive Virtual Inertia
Hou, X., Sun, Y., Zhang, X., Lu, J., Wang, P., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923734 · Cited by 367
Charging Infrastructure and Grid Integration for Electromobility
Rivera, S., Goetz, S. M., Kouro, S., Lehn, P. W., Pathmanathan, M., Bauer, P., & Mastromauro, R. A. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3216362 · Cited by 233
Evaluation of Virtual Inertia Control Strategies for MMC-based HVDC Terminals by P-HiL Experiments
D'Arco, S., Nguyen, T. T., & Suul, J. A. (2019) · IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2019.8927704 · Cited by 12
Metadata
- Authors
- Beck, H.-P., & Hesse, R.
- Venue
- 2007 9th International Conference on Electrical Power Quality and Utilisation
- Publisher
- IEEE
- Published
- 2007-10
- Pages
- 1-6
- OpenAlex
- W2040846055
- Cited by
- 1,097
- References
- 0
- FWCI
- 0.57
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Virtual synchronous machine. https://app.cochat.ai/papers/10.1109/epqu.2007.4424220
- The paper
- Beck, H.-P., & Hesse, R. (2007). Virtual synchronous machine. 2007 9th International Conference on Electrical Power Quality and Utilisation. https://doi.org/10.1109/epqu.2007.4424220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.