Analysis of airgap flux, current and vibration signals as a function of the combination of static and dynamic airgap eccentricity in 3-phase induction motors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper provides new information for the online diagnosis of airgap eccentricity in three-phase induction motors. A new theoretical analysis of the interaction between harmonic field components due to static and dynamic rotor eccentricity which previous research has not considered is put forward. The resultant harmonic current components produced in the supply current which are highlighted by the analysis are found to exist experimentally and indeed shown to be a function of the combined effect of both dynamic and static eccentricity. Further vibration analysis is put forward to identify which particular form of rotor eccentricity is dominant; hence illustrating how faults can be identified in a motor using condition monitoring techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Cameron, J. R., Thomson, W. T., & Dow, A. B. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0022 · Cited by 512
Self-citation
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Self-citationA Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Condition monitoring and fault diagnosis of electrical machines-a review
Nandi, S., & Toliyat, H. A. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.799956 · Cited by 531
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Immovilli, F., Bellini, A., Rubini, R., & Tassoni, C. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2049623 · Cited by 382
Nandi, S., Ahmed, S., & Toliyat, H. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311622 · Cited by 298
Al-Nuaim, N. A., & Toliyat, H. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.678979 · Cited by 269
Mechanical Load Fault Detection in Induction Motors by Stator Current Time-Frequency Analysis
Blodt, M., Chabert, M., Regnier, J., & Faucher, J. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.882631 · Cited by 267
Riera-Guasp, M., Antonino-Daviu, J. A., Pineda-Sanchez, M., Puche-Panadero, R., & Perez-Cruz, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004378 · Cited by 267
da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.909060 · Cited by 266
Frosini, L., & Bassi, E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026770 · Cited by 254
Study of Rotor Faults in Induction Motors Using External Magnetic Field Analysis
Ceban, A., Pusca, R., & Romary, R. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2163285 · Cited by 249
“Although in theory, this component exists only in the case of a machine with dynamic eccentricity [35], [36], but in reality other machines regarded as perfect also present a component”
BackgroundPerformance analysis of a three-phase induction motor under mixed eccentricity condition
Nandi, S., Bharadwaj, R. M., & Toliyat, H. A. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.801995 · Cited by 245
Application of AI tools in fault diagnosis of electrical machines and drives-an overview
Awadallah, M. A., & Morcos, M. M. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811739 · Cited by 220
“Dorrell et al. [ 41 ] monitored casing vibration components at a frequency to diagnose eccentricity faults in induction motors.”
BackgroundNoise in electric machines: a review
Vijayraghavan, P., & Krishnan, R. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.793360 · Cited by 197
“It gives rise to dynamic rotor vibration and eccentricity and the exciting force due to rotor unbalance is at a frequency of Static and dynamic rotor eccentricities produce nonsupply-frequency-based vibrations which will be reflected as casing vibrations [ 20 ].”
BackgroundCurrent signature analysis of induction motor mechanical faults by wavelet packet decomposition
Ye, Z., Wu, B., & Sadeghian, A. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.819682 · Cited by 193
Seera, M., Lim, C. P., Ishak, D., & Singh, H. (2012) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2011.2178443 · Cited by 185
“Usually, the cause of stator winding faults is short circuits between a phase winding and the ground or between two phases [55].”
BackgroundThomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173
Self-citationBearing Fault Detection Via Stator Current Noise Cancellation and Statistical Control
Zhou, W., Habetler, T. G., & Harley, R. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005018 · Cited by 165
“from the supply frequency, rotor speed, and machine structure [22]–[24].”
BackgroundRajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Multisensor Wireless System for Eccentricity and Bearing Fault Detection in Induction Motors
Esfahani, E. T., Wang, S., & Sundararajan, V. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2260865 · Cited by 160
Nandi, S., & Toliyat, H. A. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.980363 · Cited by 160
“The proof uses the rotor/stator, stator/rotor coordinate transformation as described in [ 21 ].”
MethodClimente-Alarcon, V., Antonino-Daviu, J. A., Riera-Guasp, M., Puche-Panadero, R., & Escobar, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.05.001 · Cited by 78
“3 In the industrial environment, the most widely spread approach for the detection of rotor bar breakages and eccentricities, known as Motor Current Signature Analysis (MCSA) [2]-[4], has some drawbacks, such as the difficulty of being applied to machines under unloaded condition or under unbalanced supply voltages, v…”
BackgroundDetecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48
“This drive usually contains an outer speed feedback loop to set the torque reference (q-axis reference current) and two current loops to control the q- and d-axis currents.”
Background
Metadata
- Authors
- Dorrell, D. G., Thomson, W. T., & Roach, S.
- Venue
- IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting
- Publisher
- IEEE
- Published
- 2002-11-19
- Volume
- 1
- Pages
- 563-570
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2038430984
- Cited by
- 367
- References
- 1
- FWCI
- 27.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.