CoChat

Microphone Mechanomyography Sensors for Movement Analysis and Identification

Paszkiewicz, Filip P., Wilson, Samuel, Oddsson, Magnus, McGregor, Alison H., Alexandersson, Asgeir, Huo, Weiguang, Vaidyanathan, Ravi · 2022 · 2022 International Conference on Advanced Robotics and Mechatronics (ICARM)

The DOI matches its Crossref record; 45 of the 47 references it cites were found in a registry or an index.

Abstract

Muscle Activity is one of the most important signals in analysis of human movement. Commonly, optical, or inertial measurement systems are paired with electromyography (EMG) electrodes to provide an information suite for analysing human movement. In many applications in uncontrolled conditions, EMG signal acquisition may be challenging due to perspiration, changing skin impedance or the need for a reference signal. A complementary muscle monitoring modality that has been shown to overcome some of the limitations of EMG is mechanomyography (MMG), which measures the vibrations of muscle fibres during contraction. In this work, we show that MMG combined with data from an inertial measurement unit (IMU) in a novel sensing suite can be used in monitoring muscle activity during common gait activities. Data were collected from a cohort of 9 volunteers. MMG-IMU movement profiles are presented for cyclic movements e.g., walking, or ascending stairs and noncyclic movements e.g., standing up or sitting down. A multi day study was conducted which demonstrates that data collected over several days can be used to generate a general movement profile. Average correlation for leave-one-out analysis between 4 days and a 5th day was found to be 90% for sitting down motion and 64% for standing up motion. Lastly, MMGIMU sensor fusion was shown to be well suited for classification of daily movement using Support Vector Machines. With the addition of MMG muscle data increasing classification accuracy by 3%, from 91% for IMU to 94% for MMG-IMU.

Overview

Integrity signals

Registry

Crossref · 10.1109/icarm54641.2022.9959672

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 45 references

Research works printed but not linked: 4

  1. mancero-castillo, 2020, Wearable MMG-Plus-One Armband: Evaluation of Normal Force on Mechanomyography (MMG) to Enhance Human-Machine Interfacing, IEEE TNSRE, 29, 196
  2. alamdari, 2017, Chapter Two - A Review of Computational Musculoskeletal Analysis of Human Lower Extremities, 37
  3. mirek, 2007, The assessment of gait disorders in patients with Parkinson’s disease using the three-dimensional motion analysis system VICON, Neurologia i Neurochirurgia Polska, 41, 128
  4. kharb, 2011, A Review of Gait Cycle and Its Parameters, IJCEM, 13, 78

Cited by

See all 4

Metadata

Authors
Paszkiewicz, F. P., Wilson, S., Oddsson, M., McGregor, A. H., Alexandersson, A., Huo, W., & Vaidyanathan, R.
Affiliations
  • Imperial College London (GB)
  • Research and Innovation at Össur,Iceland
  • Nankai University (CN)
Venue
2022 International Conference on Advanced Robotics and Mechatronics (ICARM)
Publisher
IEEE
Published
2022-07-09
Pages
118-125
OpenAlex
W4312378312
Cited by
3
References
47
Citations by year
2026: 1 · 2024: 1 · 2023: 1
FWCI
1.02
Type
conference paper
Language
en
Open access
closed
Locations
International Conference on Advanced Robotics and Mechatronics (ICARM) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
Keywords
mechanomyography, inertial measurement unit, sensor fusion, muscle activity monitoring, gait analysis, movement classification, walking, stair climbing, support vector machine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microphone Mechanomyography Sensors for Movement Analysis and Identification. https://app.cochat.ai/papers/10.1109/icarm54641.2022.9959672
The paper
Paszkiewicz, F. P., Wilson, S., Oddsson, M., McGregor, A. H., Alexandersson, A., Huo, W., & Vaidyanathan, R. (2022). Microphone Mechanomyography Sensors for Movement Analysis and Identification. 2022 International Conference on Advanced Robotics and Mechatronics (ICARM). https://doi.org/10.1109/icarm54641.2022.9959672

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.