Microphone Mechanomyography Sensors for Movement Analysis and Identification
The DOI matches its Crossref record; 45 of the 47 references it cites were found in a registry or an index.
Abstract
Muscle Activity is one of the most important signals in analysis of human movement. Commonly, optical, or inertial measurement systems are paired with electromyography (EMG) electrodes to provide an information suite for analysing human movement. In many applications in uncontrolled conditions, EMG signal acquisition may be challenging due to perspiration, changing skin impedance or the need for a reference signal. A complementary muscle monitoring modality that has been shown to overcome some of the limitations of EMG is mechanomyography (MMG), which measures the vibrations of muscle fibres during contraction. In this work, we show that MMG combined with data from an inertial measurement unit (IMU) in a novel sensing suite can be used in monitoring muscle activity during common gait activities. Data were collected from a cohort of 9 volunteers. MMG-IMU movement profiles are presented for cyclic movements e.g., walking, or ascending stairs and noncyclic movements e.g., standing up or sitting down. A multi day study was conducted which demonstrates that data collected over several days can be used to generate a general movement profile. Average correlation for leave-one-out analysis between 4 days and a 5th day was found to be 90% for sitting down motion and 64% for standing up motion. Lastly, MMGIMU sensor fusion was shown to be well suited for classification of daily movement using Support Vector Machines. With the addition of MMG muscle data increasing classification accuracy by 3%, from 91% for IMU to 94% for MMG-IMU.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“| Gait, standing up or sitting down | Thigh muscle contraction, thigh and ankle acceleration | IMU, EMG | 195 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [195]
Citations
Cites
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268 · cited 1×
“One of the main challenges to EMG is changing skin impedance [16] which is affected by physiological factors such as level of scar tissue or dynamic factors such as sweat [17].”
BackgroundTechniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 1×
“Such changes can lead to cumulative errors [18] and low data quality.”
BackgroundGait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
A Review of Tissue Substitutes for Ultrasound Imaging
Culjat, M. O., Goldenberg, D., Tewari, P., & Singh, R. S. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.012 · Cited by 659 · cited 1×
“A block of 12% concentrated gelatine was placed on the signal generator to transfer the vibrations of the metal plate to the sensor and to mimic the low pass filtering effects of human skin and muscle [38].”
MethodMuscle sound: bases for the introduction of a mechanomyographic signal in muscle studies.
Orizio, C. (1993) · PubMed · Cited by 523
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443 · cited 1×
“The value of 4Hz was chosen as in gait applications, as window sizes of more than 300ms gives low identification error and high real-time controllability [42].”
MethodToward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B., & Yang, G.-Z. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443 · cited 1×
“creasingly used both inside and outside clinical settings [9], [10].”
BackgroundEvaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Electromyography: Physiology, Engineering and Non-Invasive Applications
Madhavan, G. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8160-y · Cited by 362 · cited 1×
“EMG has seen widespread use in monitoring neuromuscular disorders [14], rehabilitation, gait analysis [15], and exercise physiology.”
BackgroundClinical gait analysis: A review
Whittle, M. W. (1996) · Human Movement Science · doi:10.1016/0167-9457(96)00006-1 · Cited by 349
Digital Signal Processing: Fundamentals and Applications
Tan, L., & Jiang, J. (2013) · doi:10.1016/c2011-0-05250-x · Cited by 339
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332 · cited 1×
“of EMG signal, a single muscle being involved in multi-joint movements, and activity of antagonist muscles affecting the generation of joint torque, make control of devices such as exoskeletons [21] and prosthetic [22]–[24] challenging.”
BackgroundElectromyography. Physiology, engineering and non invasive applications
Merletti, R., & Parker, P. (2004) · CERN Document Server (European Organization for Nuclear Research) · Cited by 329
Alterations in muscle activation patterns during robotic-assisted walking
Hidler, J. M., & Wall, A. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.09.016 · Cited by 309 · cited 1×
“Those findings are in line with results found in EMG based literature [44], [45], although with lower than expected”
ResultBiomechanics and muscular activity during sit-to-stand transfer
Roebroeck, M. E., Doorenbosch, C. A. M., Harlaar, J., Jacobs, R., & Lankhorst, G. J. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90004-3 · Cited by 299
Edinburgh Visual Gait Score for Use in Cerebral Palsy
Read, H. S., Hazlewood, M. E., Hillman, S. J., Prescott, R. J., & Robb, J. E. (2003) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200305000-00005 · Cited by 234 · cited 2×
“Vicon has been used in analysis of gait and movement abnormalities due to illness (e.g., Parkinson’s Disease [3] or Cerebral Palsy [4]) or physiological application (e.g., amputation [5] or rehabilitation [6]).”
BackgroundA Review on Accelerometry-Based Gait Analysis and Emerging Clinical Applications
Jarchi, D., Pope, J., Lee, T. K. M., Tamjidi, L., Mirzaei, A., & Sanei, S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2807182 · Cited by 224 · cited 1×
“creasingly used both inside and outside clinical settings [9], [10].”
BackgroundA Kinematic and Electromyographic Study of Shoulder Rehabilitation Exercises
MCCANN, P. D., WOOTTEN, M. E., KADABA, M. P., & BIGLIANI, L. U. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199303000-00023 · Cited by 208 · cited 1×
“, amputation [5] or rehabilitation [6]).”
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185 · cited 1×
“of EMG signal, a single muscle being involved in multi-joint movements, and activity of antagonist muscles affecting the generation of joint torque, make control of devices such as exoskeletons [21] and prosthetic [22]–[24] challenging.”
BackgroundClinical applications of surface electromyography in neuromuscular disorders
Hogrel, J.-Y. (2005) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2005.03.001 · Cited by 164 · cited 1×
“EMG has seen widespread use in monitoring neuromuscular disorders [14], rehabilitation, gait analysis [15], and exercise physiology.”
BackgroundMechanomyography and muscle function assessment: A review of current state and prospects
Ibitoye, M. O., Hamzaid, N. A., Zuñiga, J. M., & Wahab, A. K. A. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.04.003 · Cited by 163
Complementary Observer for Body Segments Motion Capturing by Inertial and Magnetic Sensors
Fourati, H., Manamanni, N., Afilal, L., & Handrich, Y. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2225151 · Cited by 157
Fang, C., He, B., Wang, Y., Cao, J., & Gao, S. (2020) · Biosensors · doi:10.3390/bios10080085 · Cited by 147 · cited 1×
“Low data quality and the resultant low robustness pose a challenge EMG based identification, especially when used in multisensory suites [19].”
BackgroundMechanomyogram for Muscle Function Assessment: A Review
Islam, M. A., Sundaraj, K., Ahmad, R. B., & Ahamed, N. U. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058902 · Cited by 134 · cited 1×
“skin impedance and perspiration levels [27].”
Colborne, G., Naumann, S., Longmuir, P. E., & Berbrayer, D. (1992) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199210000-00004 · Cited by 132
Stair climbing detection during daily physical activity using a miniature gyroscope
Coley, B., Najafi, B., Paraschiv-Ionescu, A., & Aminian, K. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.08.008 · Cited by 131 · cited 1×
“To analyse muscle activation in all 5 activities, recorded MMG data was first segmented, using known IMU gait profiles [41], and subsequently high-pass filtered at 4Hz with a 4th order Butterworth filter.”
MethodSurface Electromyography Applied to Gait Analysis: How to Improve Its Impact in Clinics?
Agostini, V., Ghislieri, M., Rosati, S., Balestra, G., & Knaflitz, M. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00994 · Cited by 131
EMG Processing Based Measures of Fatigue Assessment during Manual Lifting
Shair, E. F., Ahmad, S. A., Marhaban, M. H., Tamrin, S. B. M., & Abdullah, A. R. (2017) · BioMed Research International · doi:10.1155/2017/3937254 · Cited by 110
Acoustic myography for investigating human skeletal muscle fatigue
Stokes, M. J., & Dalton, P. A. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.71.4.1422 · Cited by 106 · cited 1×
“a combination of lateral vibrations at the muscle’s resonant frequency, vibrations caused by the volumetric changes of the active motor units, and gross lateral movement of the muscle, which causes low frequency vibration in the muscle body during initial contraction [25].”
BackgroundAn Extended Complementary Filter for Full-Body MARG Orientation Estimation
Madgwick, S., Wilson, S., Turk, R., Burridge, J. H., Kapatos, C., & Vaidyanathan, R. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2992296 · Cited by 103 · cited 1×
“The IMU consist of Microcontroller (PIC24FJ64GA104), Wireless Module (BT900) and UARTUSB converter (FT232R) [32].”
Self-citationThe effect of perspiration on the sEMG amplitude and power spectrum
Abdoli-Eramaki, M., Damecour, C., Christenson, J., & Stevenson, J. M. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.04.009 · Cited by 100 · cited 1×
“One of the main challenges to EMG is changing skin impedance [16] which is affected by physiological factors such as level of scar tissue or dynamic factors such as sweat [17].”
BackgroundFormulation of a new gradient descent MARG orientation algorithm: Case study on robot teleoperation
Wilson, S., Eberle, H., Hayashi, Y., Madgwick, S., McGregor, A. H., Jing, X., & Vaidyanathan, R. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.04.064 · Cited by 86 · cited 2×
“demonstrated in muscle monitoring [28], Human Machine Interfaces [29], [30], and upper-limb prosthesis [31].”
BackgroundSelf-citationPervasive Monitoring of Motion and Muscle Activation: Inertial and Mechanomyography Fusion
Woodward, R. B., Shefelbine, S. J., & Vaidyanathan, R. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2715163 · Cited by 68
Self-citationCastaingts, V., Martin, A., Hoecke, J. V., & Pérot, C. (2004) · Chronobiology International · doi:10.1081/cbi-120039207 · Cited by 63
Trends and Challenges in EMG Based Control Scheme of Exoskeleton Robots- A Review
Singh, R., & Chatterji, S. (2012) · Cited by 62
Upper-limb prosthetic control using wearable multichannel mechanomyography
Wilson, S., & Vaidyanathan, R. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009427 · Cited by 62
Self-citationWhole-Body Pose Estimation in Human Bicycle Riding Using a Small Set of Wearable Sensors
Zhang, Y., Chen, K., Yi, J., Liu, T., & Pan, Q. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2490118 · Cited by 61 · cited 1×
“When a cheaper or more portable system is required, miniature embedded systems such as inertial measurement units (IMUs) can be considered instead [7], [8].”
BackgroundPosatskiy, A. O., & Chau, T. T. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.12.007 · Cited by 48 · cited 2×
“The sensor design is based on the work of Posatskiy and Chau [34], and has previously been validated in pervasive monitoring of motion and muscle activation applications [35].”
MethodCastillo, C. S. M., Wilson, S., Vaidyanathan, R., & Atashzar, S. F. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3043368 · Cited by 44
Self-citationTime-of-Day Effects on EMG Parameters During the Wingate Test in Boys.
Souissi, H., Chtourou, H., Chaouachi, A., Chamari, K., Souissi, N., & Amri, M. (2012) · Europe PMC (PubMed Central) · Cited by 38
A Review of EMG Techniques for Detection of Gait Disorders
Singh, R. E., Iqbal, K., White, G., & Holtz, J. K. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.84403 · Cited by 25
The muscle activation patterns of lower limb during stair climbing at different backpack load
Han, Y., Song, A., Haitao, G., & Zhu, S. (2015) · PubMed · doi:10.5277/abb-00155-2014-06 · Cited by 21 · cited 1×
“Those findings are in line with results found in EMG based literature [44], [45], although with lower than expected”
ResultOptimization of the signal-to-noise ratio of silicon-embedded microphones for mechanomyography
Silva, J., Chau, T. T., Naumann, S., Helm, W., & Goldenberg, A. A. (2004) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2003.1226187 · Cited by 16
Research works printed but not linked: 4
- mancero-castillo, 2020, Wearable MMG-Plus-One Armband: Evaluation of Normal Force on Mechanomyography (MMG) to Enhance Human-Machine Interfacing, IEEE TNSRE, 29, 196
- alamdari, 2017, Chapter Two - A Review of Computational Musculoskeletal Analysis of Human Lower Extremities, 37
- mirek, 2007, The assessment of gait disorders in patients with Parkinson’s disease using the three-dimensional motion analysis system VICON, Neurologia i Neurochirurgia Polska, 41, 128
- kharb, 2011, A Review of Gait Cycle and Its Parameters, IJCEM, 13, 78
Cited by
Wang, W., Ren, H., Su, S., Zhang, P., & Zhang, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.115728 · Cited by 14
Wearable sensing for understanding and influencing human movement in ecological contexts
Adamczyk, P. G., Harper, S. E., Reiter, A. J., Roembke, R. A., Wang, Y., Nichols, K. M., & Thelen, D. G. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100492 · Cited by 14
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Liu, C., Jin, X., & Yu, Z. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.15600
“A Mylar membrane closes the skin-facing opening in the Posatskiy– Chau chamber and later armband and gait sensors [2], [10], [14], and Jin et al. filled their chamber with damping silicone [4].”
Metadata
- Authors
- Paszkiewicz, F. P., Wilson, S., Oddsson, M., McGregor, A. H., Alexandersson, A., Huo, W., & Vaidyanathan, R.
- Affiliations
- Imperial College London (GB)
- Research and Innovation at Össur,Iceland
- Nankai University (CN)
- Venue
- 2022 International Conference on Advanced Robotics and Mechatronics (ICARM)
- Publisher
- IEEE
- Published
- 2022-07-09
- Pages
- 118-125
- OpenAlex
- W4312378312
- Cited by
- 3
- References
- 47
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1
- FWCI
- 1.02
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Advanced Robotics and Mechatronics (ICARM) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- mechanomyography, inertial measurement unit, sensor fusion, muscle activity monitoring, gait analysis, movement classification, walking, stair climbing, support vector machine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.