Acoustic myography for investigating human skeletal muscle fatigue
Abstract
Sounds produced during voluntary isometric contractions of the quadriceps muscle were studied by acoustic myography (AMG) in five healthy adults. With the subject seated, isometric force, surface electromyography (EMG), and AMG were recorded over rectus femoris, and the EMG and AMG signals were integrated (IEMG and IAMG). Contractions lasting 5 s each were performed at 10, 25, 50, 60, 75, and 100% of maximum voluntary contraction (MVC) force. Fatigue was then induced by repeated voluntary contractions (10 s on, 10 s off) at 75% MVC until only 40% MVC could be sustained. After 15 min of rest, the different force levels were again tested in relation to the fresh MVC. Both before and after fatiguing activity the relationships between force and IEMG [r = 0.99 +/- 0.01 (SD), n = 10] and force and IAMG (r = 0.98 +/- 0.02) were linear. After activity, however, the slopes of the regression lines for force and IEMG increased (P less than 0.01) but those for force and IAMG remained the same (P greater than 0.05). The present results clarify the relationship between AMG and isometric force in fatigued muscle without the problem of fatigue-induced tremor, which hampered previous studies of prolonged activity. This study contributes to the validation of AMG and shows that it is a potentially useful method for noninvasive assessment of force production and fatigue. Further studies to establish the origin of AMG activity are required before AMG can be accepted for use in neuromuscular physiology or rehabilitation.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cited by
Sorted by citations
Tsuji, H., Misawa, H., Takigawa, T., Tetsunaga, T., Yamane, K., Oda, Y., & Ozaki, T. (2021) · Scientific Reports · doi:10.1038/s41598-021-81874-5 · Cited by 16 · see citing works
Microphone Mechanomyography Sensors for Movement Analysis and Identification
Paszkiewicz, F. P., Wilson, S., Oddsson, M., McGregor, A. H., Alexandersson, A., Huo, W., & Vaidyanathan, R. (2022) · 2022 International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm54641.2022.9959672 · Cited by 3 · see citing works
- Authors
- Stokes, M. J., & Dalton, P. A.
- Affiliations
- The University of Queensland (AU)
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-10-01
- Volume
- 71
- Issue
- 4
- Pages
- 1422-1426
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2399415105
- Cited by
- 106
- References
- 0
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2022: 6 · 2021: 2 · 2020: 3 · 2019: 2 · 2018: 4 · 2017: 4 · 2016: 5 · 2014: 4 · 2013: 1 · 2012: 2
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- mechanomyography, skeletal muscle fatigue, quadriceps, isometric contraction, surface electromyography, rectus femoris, force generation, neuromuscular physiology, rehabilitation assessment
- MeSH terms
- Acoustics, Adult, Electromyography, Humans, Isometric Contraction, Male, Muscle Contraction, Muscles, Myography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review