Real-Time Modeling and Prediction of Physiological Hand Tremor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper provides results of our investigation of adaptive algorithms for real-time modeling and prediction of physiological tremor signals. The goal of the investigation is to find effective methods which are suitable for small embedded systems used in real-time signal processing of physiological hand tremor. Our investigation shows that physiological hand tremor can be represented with an AR(3) process. Based on this fact, it is possible to identify the model of the physiological hand tremor with simple adaptive algorithms. On the other hand an adaptive linear predictor can also be realized, based on the same adaptive algorithms, which is significant for the suppression of physiological hand tremor in hand-held tools.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Higher order statistics and neural network for tremor recognition
Jakubowski, J., Kwiatos, K., Chwaleba, A., & Osowski, S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979354 · Cited by 78
Research works printed but not linked: 4
- 10.1142/S0218127498001157 · DOI · Paper page
- 10.1016/S0165-0270(98)00064-8 · DOI
- proakis, 2002, Algorithms for Statistical Signal Processing
- riviere, 2001, Design and implementation of active error canceling in hand-held microsurgical instrument, Processings of the 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems, 1106
Cited by
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117
“Although linear filters [16,17] are successful in compensating tremor, the inherent time delay [18] is a major drawback where zero-phase filtering is required.”
BackgroundBandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352922 · Cited by 83
Veluvolu, K. C., & Ang, W. T. (2010) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.340 · Cited by 83
Veluvolu, K. C., Latt, W. T., & Ang, W. T. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.06.001 · Cited by 65
Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
Metadata
- Authors
- Zhang, J., & Chu, F.
- Venue
- Proceedings. (ICASSP '05). IEEE International Conference on Acoustics, Speech, and Signal Processing, 2005.
- Publisher
- IEEE
- Published
- 2006-10-04
- Volume
- 5
- Pages
- 645-648
- ISSN
- 1520-6149 (ISSN-L)
- OpenAlex
- W2116171479
- Cited by
- 43
- References
- 1
- FWCI
- 6.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Modeling and Prediction of Physiological Hand Tremor. https://app.cochat.ai/papers/10.1109/icassp.2005.1416386
- The paper
- Zhang, J., & Chu, F. (2006). Real-Time Modeling and Prediction of Physiological Hand Tremor. Proceedings. (ICASSP '05). IEEE International Conference on Acoustics, Speech, and Signal Processing, 2005. https://doi.org/10.1109/icassp.2005.1416386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.