The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
Abstract
Accurate canceling of physiological tremor is extremely important in robotics-assisted surgical instruments/procedures. The performance of robotics-based hand-held surgical devices degrades in real time due to the presence of phase delay in sensors (hardware) and filtering (software) processes. Effective tremor compensation requires zero-phase lag in filtering process so that the filtered tremor signal can be used to regenerate an opposing motion in real time. Delay as small as 20 ms degrades the performance of human-machine interference. To overcome this phase delay, we employ multistep prediction in this paper. Combined with the existing tremor estimation methods, the procedure improves the overall accuracy by 60% for tremor estimation compared to single-step prediction methods in the presence of phase delay. Experimental results with developed methods for 1-DOF tremor estimation highlight the improvement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is shown50 that a phase-lag as low as 20 ms in the signal filtering part noticeably degrades the system performance.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [50]
In the citing paper
“Moreover, factors such as anxiety and fatigue can modulate the magnitude and the spectrum of the physiological tremor significantly [2].”
From A Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor (2016) · cites this paper as [2]
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
Rogers, S. (1996) · Control Engineering Practice · doi:10.1016/0967-0661(96)82838-3 · Cited by 9,278
(1991) · Springer eBooks · doi:10.1007/978-3-7091-2840-4 · Cited by 5,095
(1986) · Signal Processing · doi:10.1016/0165-1684(86)90025-3 · Cited by 1,594
25 years of time series forecasting
De Gooijer, J. G., & Hyndman, R. J. (2006) · International Journal of Forecasting · doi:10.1016/j.ijforecast.2006.01.001 · Cited by 1,587
Discrete-Time Signal Processing
Jenkins, W. K., Jones, D. L., & Hunsinger, B. J. (2002) · Reference Data for Engineers · doi:10.1016/b978-075067291-7/50030-3 · Cited by 536
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508 · cited 1×
“2264546 in the frequency range of 8–12 Hz [11], [12].”
BackgroundEvolution of autonomous and semi‐autonomous robotic surgical systems: a review of the literature
Moustris, G. P., Hiridis, S. C., Deliparaschos, K. M., & Konstantinidis, K. M. (2011) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.408 · Cited by 321
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citation
Research works printed but not linked: 2
- elbe, 1985, Tremor
- charles, 1996, Dexterity Enhancement for Surgery
Cited by
First-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
Tatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
Self-citationA Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor
Adhikari, K., Tatinati, S., Ang, W. T., Veluvolu, K. C., & Nazarpour, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2530564 · Cited by 48
Self-citationAtashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“It is shown 50 that a phase-lag as low as 20 ms in the signal filtering part noticeably degrades the system performance.”
Background
Metadata
- Authors
- Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T.
- Affiliations
- Kyungpook National University (KR)
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-11
- Volume
- 60
- Issue
- 11
- Pages
- 3074-3082
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2091990540
- Cited by
- 51
- References
- 38
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 6 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 6 · 2015: 2 · 2014: 5 · 2013: 1
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- physiological tremor, tremor compensation, multi-step forecasting, phase lag, sensor delay, zero-phase filtering, human-machine interaction
- MeSH terms
- Algorithms, Fourier Analysis, Hand, Humans, Robotics, Task Performance and Analysis, Tremor, Models, Statistical, Surgery, Computer-Assisted, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multistep Prediction of Physiological Tremor for Surgical Robotics Applications. https://app.cochat.ai/papers/10.1109/tbme.2013.2264546
- The paper
- Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013). Multistep Prediction of Physiological Tremor for Surgical Robotics Applications. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2013.2264546
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.