Cited by 45Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlECG Monitoring and Analysis

Analysis and detection of motion artifact in photoplethysmographic data using higher order statistics

Krishnan, Rajet, Natarajan, Balasubramaniam, Warren, Steve·2008·2008 IEEE International Conference on Acoustics, Speech and Signal Processing

Abstract

In this work, we present novel methods for detecting the presence of motion artifact in photoplethysmographic (PPG) measurements based on higher order statistical information present in the data. We analyze both clean and corrupt PPG data in the time and frequency domains. In the time domain, skew and kurtosis measures of the signal are used as distinguishing metrics between clean and motion- corrupted data. In the frequency domain, the presence of random components due to motion artifact is analyzed using a frequency domain kurtosis measure. Additionally, bispectral analysis of PPG data indicates the presence of strong quadratic phase coupling (QPC) and more specifically self coupling in the case of clean PPG data. Though quadratic phase coupling is found in data corrupted by motion artifact, the self coupling feature is absent. A Neyman-Pearson (NP) detection rule is formulated for each of the measures. Additionally, treating each of the measures as observations from independent sensors, the Varshney-Chair rule is used to fuse individual decisions to form a global system decision.

Integrity signals

Registry

Crossref · 10.1109/icassp.2008.4517684

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Krishnan, R., Natarajan, B., & Warren, S.
Affiliations
Kansas State University (US)
Venue
2008 IEEE International Conference on Acoustics, Speech and Signal Processing
Publisher
IEEE
Published
2008-03
Pages
613-616
ISSN
1520-6149 (ISSN-L)
OpenAlex
W1992974489
Cited by
45
References
10
Citations by year
2025: 4 · 2024: 5 · 2023: 2 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 1 · 2012: 3
FWCI
5.07
Type
conference paper
Language
en
Open access
closed
Locations
IEEE International Conference on Acoustics Speech and Signal Processing (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
motion artifact detection, photoplethysmography, higher-order statistics, skewness, kurtosis, bispectral analysis, quadratic phase coupling, self-coupling, Neyman-Pearson detection, decision fusion, PPG signal quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review