Learning from other subjects helps reducing Brain-Computer Interface calibration time
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A major limitation of Brain-Computer Interfaces (BCI) is their long calibration time, as much data from the user must be collected in order to tune the BCI for this target user. In this paper, we propose a new method to reduce this calibration time by using data from other subjects. More precisely, we propose an algorithm to regularize the Common Spatial Patterns (CSP) and Linear Discriminant Analysis (LDA) algorithms based on the data from a subset of automatically selected subjects. An evaluation of our approach showed that our method significantly outperformed the standard BCI design especially when the amount of data from the target user is small. Thus, our approach helps in reducing the amount of data needed to achieve a given performance level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Self-citationOptimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
The Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338
Cited by
Regularizing Common Spatial Patterns to Improve BCI Designs: Unified Theory and New Algorithms
Lotte, F., & Guan, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082539 · Cited by 1,045
Self-citationTransfer Learning for Brain–Computer Interfaces: A Euclidean Space Data Alignment Approach
He, H., & Wu, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913914 · Cited by 569
Jirayucharoensak, S., Pan-Ngum, S., & Israsena, P. (2014) · The Scientific World Journal · doi:10.1155/2014/627892 · Cited by 486
Lotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327
Self-citationOnline and Offline Domain Adaptation for Reducing BCI Calibration Effort
Wu, D. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2608931 · Cited by 114
Metadata
- Authors
- Lotte, F., & Guan, C.
- Venue
- 2010 IEEE International Conference on Acoustics, Speech and Signal Processing
- Publisher
- IEEE
- Published
- 2010
- Pages
- 614-617
- ISSN
- 1520-6149 (ISSN-L)
- OpenAlex
- W1973574316
- Cited by
- 144
- References
- 6
- FWCI
- 15.48
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Learning from other subjects helps reducing Brain-Computer Interface calibration time. https://app.cochat.ai/papers/10.1109/icassp.2010.5495183
- The paper
- Lotte, F., & Guan, C. (2010). Learning from other subjects helps reducing Brain-Computer Interface calibration time. 2010 IEEE International Conference on Acoustics, Speech and Signal Processing. https://doi.org/10.1109/icassp.2010.5495183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.