Signal Processing Approaches to Minimize or Suppress Calibration Time in Oscillatory Activity-Based Brain–Computer Interfaces
Open accessThe DOI matches its Crossref record; 86 of the 88 references it cites were found in a registry or an index.
Abstract
One of the major limitations of brain-computer interfaces (BCI) is their long calibration time, which limits their use in practice, both by patients and healthy users alike. Such long calibration times are due to the large between-user variability and thus to the need to collect numerous training electroencephalography (EEG) trials for the machine learning algorithms used in BCI design. In this paper, we first survey existing approaches to reduce or suppress calibration time, these approaches being notably based on regularization, user-to-user transfer, semi-supervised learning and a priori physiological information. We then propose new tools to reduce BCI calibration time. In particular, we propose to generate artificial EEG trials from the few EEG trials initially available, in order to augment the training set size. These artificial EEG trials are obtained by relevant combinations and distortions of the original trials available. We propose three different methods to do so. We also propose a new, fast and simple approach to perform user-to-user transfer for BCI. Finally, we study and compare offline different approaches, both old and new ones, on the data of 50 users from three different BCI data sets. This enables us to identify guidelines about how to reduce or suppress calibration time for BCI.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, the BCI system requires a long calibration phase before each time it is used because, to achieve a good performance, every subject’s BCI system needs to be trained by their own EEG signals and cannot use other’s EEG signals [11].”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [11]
In the citing paper
“In addition, the BCI system requires a long calibration phase before each time it is used because, to achieve a good performance, every subject’s BCI system needs to be trained by their own EEG signals and cannot use other’s EEG signals [11].”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [11]
In the citing paper
“Classification must generalize across subjects, since per-subject calibration delays setup and limits scalability [4]”
From ERP-XTTN: interpretable prototype-guided cross-attention for cross-subject ERP classification (2026) · cites this paper as [4]
Citations
Cites
Caruana, R. (1997) · Machine Learning · doi:10.1023/a:1007379606734 · Cited by 6,636 · cited 1×
“…guide the optimization algorithms towards good solutions, similar to that of the other users, thus enabling a better learning from little data. b) Multi-task learning: Multi-task learning consists of learning simultaneously multiple tasks that share some constraints or prior information [37].”
BackgroundSemi-Supervised Learning Literature Survey
Zhu, X. (2005) · Minds at UW (University of Wisconsin) · Cited by 4,505
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046 · cited 3×
“More precisely, it is known that when covariance matrices are estimated from too little training data, their largest and smallest eigen values will be, respectively, over and under estimated [32].”
BackgroundMethodInfluentialA review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 2×
“The LDA classifier uses a linear hyperplane to separate feature vectors from two classes [10].”
MethodSelf-citationOptimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 3×
“Since the variance of a band-pass filtered signal corresponds to the band-power of the signal in that band, CSP optimizes spatial filters that lead to optimally discriminant band-power features [29].”
BackgroundMethodInfluentialMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“As an example, during left hand motor imagery (i.e., the imagination of a left hand movement), the EEG band power in the (cid:2) (8–12 Hz) and (16–24 Hz) frequency bands will decrease in the right sensorimotor cortex [30].”
BackgroundA tutorial on Principal Components Analysis
Smith, L. I. (2002) · Otago University Research Archive (University of Otago) · Cited by 1,636
Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264 · cited 1×
“…and classifier optimization from limited training data), several algorithms being available to optimize such bands with CSP and LDA; see, e.g., [75]–[81]; 2) outlier/ artifact removal in small sample size settings, as when little data is available, a single outlier (artefacts being…”
MethodSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138 · cited 1×
“Since this is a simple, computationally efficient and parameter free method, we advocate that it should become a standard tool for BCI design, including for oscillatory activity-based BCI (it is already becoming a rather standard tool for ERP classification [74]).”
MethodAn EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114 · cited 2×
“, [2] and [3].”
Research works printed but not linked: 3
- tu, 0, Dynamical ensemble learning with model-friendly classifiers for domain adaptation, Proc IEEE ICPR, 1181
- lu, 0, Boosting-based subject-independent brain computer interface, Proc ICPR
- meng, 2014, Improved semi-supervised adaptation for small training data set in brain-computer interface, IEEE J Biomed Health Inform, 18
Cited by
EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2016) · arXiv · doi:10.48550/arxiv.1611.08024 · Cited by 5,105
EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
“robustness of the LDA to mislabelling [137].”
BackgroundSelf-citationEEG Conformer: Convolutional Transformer for EEG Decoding and Visualization
Song, Y., Zheng, Q., Liu, B., & Gao, X. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3230250 · Cited by 1,095
“Follow [37], the training samples of the same category are equally divided into N s segments, then randomly concatenated while maintaining the original time order.”
BackgroundA comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Metadata
- Authors
- Lotte, F.
- Affiliations
- Centre Inria de l'université de Bordeaux (FR)
- Corresponding author
- Lotte, Fabien
- ORCID
- Lotte, Fabien
- Venue
- Proceedings of the IEEE
- Published
- 2015-06
- Volume
- 103
- Issue
- 6
- Pages
- 871-890
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W1610928686
- Cited by
- 327
- References
- 88
- Citations by year
- 2026: 29 · 2025: 45 · 2024: 36 · 2023: 28 · 2022: 38 · 2021: 30 · 2020: 36 · 2019: 29 · 2018: 25 · 2017: 12 · 2016: 16 · 2015: 3
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- green
- inria.hal.science
- Locations
- Proceedings of the IEEE (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- brain-computer interface, calibration time reduction, EEG, neural oscillations, semi-supervised learning, regularization, data augmentation, training data size
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Signal Processing Approaches to Minimize or Suppress Calibration Time in Oscillatory Activity-Based Brain–Computer Interfaces. https://app.cochat.ai/papers/10.1109/jproc.2015.2404941
- The paper
- Lotte, F. (2015). Signal Processing Approaches to Minimize or Suppress Calibration Time in Oscillatory Activity-Based Brain–Computer Interfaces. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2015.2404941
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.