Cited by 23Context-Aware Activity Recognition SystemsPhonocardiography and Auscultation TechniquesNon-Invasive Vital Sign Monitoring

Coughtrigger: Earbuds IMU Based Cough Detection Activator Using An Energy-Efficient Sensitivity-Prioritized Time Series Classifier

Open access
Zhang, Shibo, Nemati, Ebrahim, Dinh, Minh, Folkman, Nathan, Ahmed, Tousif, Rahman, Mahbubur, Kuang, Jilong, Alshurafa, Nabil +1 more·2022·ICASSP 2022 - 2022 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)

Abstract

Persistent coughs are a major symptom of respiratory-related diseases. Increasing research attention has been paid to detecting coughs using wearables, especially during the COVID-19 pandemic. Microphone is most widely used sensor to detect coughs. However, the intense power consumption needed to process audio hinders continuous audio-based cough detection on battery-limited commercial wearables, such as earbuds. We present CoughTrigger, which utilizes a lower-power sensor, inertial measurement unit (IMU), in earbuds as a cough detection activator to trigger a higher-power sensor for audio processing and classification. It runs all-the-time as a standby service with minimal battery consumption and triggers the audio-based cough detection when a candidate cough is detected from IMU. Besides, the use of IMU brings the benefit of improved specificity of cough detection. Experiments are conducted on 45 subjects and CoughTrigger achieved 0.77 AUC score. We also validated its effectiveness on free-living data and through on-device implementation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/icassp43922.2022.9746334

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Xiao Sun, Zongqing Lu, Wenjie Hu, and Guohong Cao, "Symdetector: Detecting sound-related respira- tory symptoms using smartphones," in Proceedings of the 2015 ACM International Joint Conference on Perva- sive and Ubiquitous Computing, New York, NY, USA, 2015, UbiComp '15, p. 97-108, Association for Com- puting Machinery.

Cited by

Sorted by citations

Authors
Zhang, S., Nemati, E., Dinh, M., Folkman, N., Ahmed, T., Rahman, M., Kuang, J., Alshurafa, N., & Gao, A.
Affiliations
  • Northwestern University (US)
  • Samsung Research America,Mountain View,CA,USA
  • Samsung Design Innovation Center,San Francisco,CA,USA
Venue
ICASSP 2022 - 2022 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)
Publisher
IEEE
Published
2022-05-23
Pages
1-5
ISSN
1520-6149 (ISSN-L)
OpenAlex
W3212191366
Cited by
23
References
15
Citations by year
2026: 1 · 2025: 6 · 2024: 2 · 2023: 8 · 2022: 6
FWCI
1.99
Type
conference paper
Language
en
Open access
Locations
IEEE International Conference on Acoustics Speech and Signal Processing (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
cough detection, earbuds, inertial measurement unit, energy-efficient sensing, sensor fusion, wearable devices, battery consumption, COVID-19 pandemic, respiratory diseases, time series classification

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review