Cited by 2Power Systems Fault DetectionElectrical Fault Detection and ProtectionPower System Optimization and Stability

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

Open access
Oelhaf, Julian, Kordowich, Georg, Pérez-Toro, Paula Andrea, Arias-Vergara, Tomás, Maier, Andreas, Jäger, Johann, Bayer, Siming·2025·ICASSP 2025 - 2025 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)

Abstract

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval—a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991±0.018 and demonstrated a processing time of 0.342ms±0.509ms.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/icassp49660.2025.10890544

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The RF classifier's reported performance is F1-score 0.998 for FD and 0.985 for FLI, with a runtime of 16.8 ms.

    “The reported F1-score is 0.998 for FD, 0.985 for FLI, with a runtime of 16.8 ms.”

    From Impact of Data Sparsity on Machine Learning for Fault Detection in Power System Protection (2025) · cites this paper as [8]

    The Discussion (page not provided) includes RF among the top-performing models and reports mean F1 scores of up to 0.99 for fault detection and 0.98 for fault-line identification. Neither it nor the Experiments and Results passage (page not provided) gives the claimed RF-specific scores of 0.998 and 0.985 or a 16.8 ms runtime. (LLM, conf=0.83)

    Experimental — accuracy not yet measured
  • The Random Forest classifier was selected based on a comparative study [8] that demonstrated its favorable trade-off between performance and runtime.

    “The Random Forest (RF) classifier is selected based on our comparative study [8], which demonstrated its favorable trade-off between performance and runtime.”

    From Impact of Data Sparsity on Machine Learning for Fault Detection in Power System Protection (2025) · cites this paper as [8]

    The Experiments and Results section compares RF with other classifiers and lists it among the best performers. The Discussion also reports that RF is among the top-performing models, but identifies MLP, GB, and Stacking—not RF—as combining the highest scores with competitive runtimes. The paper therefore supports using the study to assess RF, but does not establish the claimed favorable performance–runtime trade-off for RF specifically. No page numbers are available in our copy. (LLM, conf=0.84)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. W.-K. Chen, The electrical engineering handbook. Elsevier Academic Press, 2005, OCLC: 57371415.
  2. IEEE Power and Energy Society, "IEEE guide for determining fault location on AC transmission and distribution lines." [Online]. Available: http://ieeexplore.ieee.org/document/7024095/
  3. M. Wang, G. Kordowich, and J. Jäger, "A generic data generation framework for short circuit detection training of neural networks," in PESS + PELSS 2022; Power and Energy Student Summit. VDE, 2022, pp. 49-54. [Online]. Available: https://ieeexplore.ieee.org/document/ 10104226

Cited by

Sorted by citations

Authors
Oelhaf, J., Kordowich, G., Pérez-Toro, P. A., Arias-Vergara, T., Maier, A., Jäger, J., & Bayer, S.
Affiliations
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
  • Friedrich-Alexander-University Erlangen-Nuremberg,Pattern Recognition Lab,Erlangen,Germany
  • Institute of Electrical Energy Systems, Friedrich-Alexander-University Erlangen-Nuremberg,Erlangen,Germany
Venue
ICASSP 2025 - 2025 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)
Publisher
IEEE
Published
2025-04-06
Pages
1-5
ISSN
1520-6149 (ISSN-L)
OpenAlex
W4408353127
Cited by
2
References
16
Citations by year
2026: 1 · 2025: 1
FWCI
4.37
Type
conference paper
Language
en
Open access
Locations
  • IEEE International Conference on Acoustics Speech and Signal Processing (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
Deutsche Forschungsgemeinschaft (535389056)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical Fault Detection and Protection
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
Keywords
fault detection, electrical power grid, machine learning, short-circuit faults, relay protection, renewable energy integration, real-time fault detection, model comparison

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review