3D-ICE: Fast compact transient thermal modeling for 3D ICs with inter-tier liquid cooling

Open access
Sridhar, Arvind, Vincenzi, Alessandro, Ruggiero, Martino, Brunschwiler, Thomas, Atienza, David · 2010 · 2010 IEEE/ACM International Conference on Computer-Aided Design (ICCAD)

Abstract

Three dimensional stacked integrated circuits (3D ICs) are extremely attractive for overcoming the barriers in interconnect scaling, offering an opportunity to continue the CMOS performance trends for the next decade. However, from a thermal perspective, vertical integration of high-performance ICs in the form of 3D stacks is highly demanding since the effective areal heat dissipation increases with number of dies (with hotspot heat fluxes up to 250 W/cm2) generating high chip temperatures. In this context, inter-tier integrated microchannel cooling is a promising and scalable solution for high heat flux removal. A robust design of a 3D IC and its subsequent thermal management depend heavily upon accurate modeling of the effects of liquid cooling on the thermal behavior of the IC during the early stages of design. In this paper we present 3D-ICE, a compact transient thermal model (CTTM) for the thermal simulation of 3D ICs with multiple inter-tier microchannel liquid cooling. The proposed model is compatible with existing thermal CAD tools for ICs, and offers significant speed-up (up to 975x) over a typical commercial computational fluid dynamics simulation tool while preserving accuracy (i.e., maximum temperature error of 3.4%). In addition, a thermal simulator has been built based on 3D-ICE, which is capable of running in parallel on multicore architectures, offering further savings in simulation time and demonstrating efficient parallelization of the proposed approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iccad.2010.5653749

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 284

Metadata

Authors
Sridhar, A., Vincenzi, A., Ruggiero, M., Brunschwiler, T., & Atienza, D.
Venue
2010 IEEE/ACM International Conference on Computer-Aided Design (ICCAD)
Publisher
IEEE
Published
2010-11
Pages
463-470
OpenAlex
W3142845206
Cited by
284
References
7
FWCI
27.51
Type
conference paper
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D-ICE: Fast compact transient thermal modeling for 3D ICs with inter-tier liquid cooling. https://app.cochat.ai/papers/10.1109/iccad.2010.5653749
The paper
Sridhar, A., Vincenzi, A., Ruggiero, M., Brunschwiler, T., & Atienza, D. (2010). 3D-ICE: Fast compact transient thermal modeling for 3D ICs with inter-tier liquid cooling. 2010 IEEE/ACM International Conference on Computer-Aided Design (ICCAD). https://doi.org/10.1109/iccad.2010.5653749

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.