Cited by 47Prosthetics and Rehabilitation RoboticsSoft Robotics and ApplicationsMuscle activation and electromyography studies

Mechanical design of the Hanyang Exoskeleton Assistive Robot(HEXAR)

Kim, Wansoo, Lee, Heedon, Kim, Donghwan, Han, Jungsoo, Han, Changsoo·2014·2014 14th International Conference on Control, Automation and Systems (ICCAS 2014)

Abstract

This study developed a lower extremity exoskeleton system to enhance lower body strength. In this paper, selected the degrees of freedom (DOF) which actuated based on analyzed human motion, and analyzed the human joint function to design the joint modules of the exoskeletal robot. To improve the efficiency of the exoskeleton robot, a mechanical structure was designed on the basis of a semi-anthropomorphic architecture. The Hanyang EXskeleton Assistive Robot (HEXAR) has seven degrees of freedom per leg, two of which are powered by an electrical motor. Appropriately sized motors and gearing are selected, and put through a thorough power analysis. quasi-passive mechanisms were designed with compliance material for supporting the weight of external loads in the stance phase and absorbing/releasing the energy. This paper discusses design criteria considered in mechanical design for HEXAR.

Integrity signals

Registry

Crossref · 10.1109/iccas.2014.6988049

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kim, W., Lee, H., Kim, D., Han, J., & Han, C.
Affiliations
Hanyang University (KR)
Venue
2014 14th International Conference on Control, Automation and Systems (ICCAS 2014)
Publisher
IEEE
Published
2014-10
Pages
479-484
OpenAlex
W2312756180
Cited by
47
References
12
Citations by year
2026: 3 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 7 · 2021: 3 · 2020: 6 · 2019: 8 · 2018: 3 · 2017: 5 · 2016: 3 · 2015: 3
FWCI
7.12
Type
conference paper
Language
en
Open access
closed
Locations
  • International Conference on Control, Automation and Systems (ICCAS) (publishedVersion)
  • The Royal Society of Chemistry’s Journals, Books and Databases (The Royal Society of Chemistry) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
lower limb exoskeleton, assistive robots, mechanical design, degrees of freedom, joint modules, power analysis, stance phase

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review