Assessing accuracy factors in deformable 2D/3D medical image registration using a statistical pelvis model
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Deformable 2D-3D medical image registration is an essential technique in computer integrated surgery (CIS) to fuse 3D pre-operative data with 2D intra-operative data. Several factors may affect the accuracy of 2D-3D registration, including the number of 2D views, the angle between views, the view angle relative to anatomical objects, the co-registration error between views, the image noise, and the image distortion. In this paper, we investigate and assess the relationship between these factors and the accuracy of 2D-3D registration. We proposed a deformable 2D-3D registration method based on a statistical model. We conducted experiments using a hemi-pelvis model and simulated X-ray images. Some discussions are provided on how to improve the accuracy of 2D-3D registration based on our assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zollei, L., Grimson, E., Norbash, A., & Wells, W. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.991032 · Cited by 120 · cited 1×
“[7] proposed a mutual information based 2D-3D registration algorithm which establishes the proper alignment via a stochastic gradient ascent strategy.”
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…et al., 2006; Mahfouz et al., 2003; Turgeon et al., 2005), or segmentation was used to generate a statistical model of the anatomy of interest and thereby avoid the need for 3D image acquisition (Tang and Ellis, 2005; Yao and Taylor, 2003; Hurvitz and Joskowicz, 2008; Sadowsky et al., 2006, 2007).”
BackgroundMethodInfluentialBaka, N., Kaptein, B. L., de Bruijne, M., van Walsum, T., Giphart, J. E., Niessen, W. J., & Lelieveldt, B. P. F. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.04.001 · Cited by 178
“, 2003), or by Statistical Shape Models (SSM) (Benameur et al., 2003; Hurvitz and Joskowicz, 2008; Kurazume et al., 2009; Lamecker et al., 2006; Lavallée et al., 1993; Tang and Ellis, 2005; Yao and Taylor, 2003; Zheng et al., 2008).”
BackgroundMethodInfluentialZheng, G., Gollmer, S., Schumann, S., Dong, X., Feilkas, T., & González Ballester, M. A. (2009) · Medical Image Analysis · doi:10.1016/j.media.2008.12.003 · Cited by 158
Deformable 2D-3D Registration of Vascular Structures in a One View Scenario
Groher, M., Zikic, D., & Navab, N. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011519 · Cited by 91
Wang, H., Stout, D. B., & Chatziioannou, A. F. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.02.009 · Cited by 16
Metadata
- Authors
- Yao, J., & Taylor
- Venue
- Proceedings Ninth IEEE International Conference on Computer Vision
- Publisher
- IEEE
- Published
- 2003
- Pages
- 1329-1334 vol.2
- OpenAlex
- W2107775699
- Cited by
- 71
- References
- 1
- FWCI
- 1.73
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.