Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
There is a need for wearable powered upper limb exoskeletons able to apply forces to the upper limb for use by people with disabilities and/or limb weakness or injury. The robotic exoskeleton called WOTAS (Wearable Orthosis for Tremor Assessment and Suppression) presented in this paper will provide a means of testing non-grounded control strategies in order to help these people. For instance, biomechanical loading, in particular, viscous loading of the upper limb has been proposed in the literature as a means for suppressing pathologic tremor. This article describes in detail the general concept for WOTAS, outlining the special features of the design and selection of system components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Tremor suppression orthoses also have been investigated10-12, which function by physically forcing a person's tremor to cease13.”
From A noninvasive handheld assistive device to accommodate essential tremor: A pilot study (2014) · cites this paper as [12]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, the problem of coupling the tremor between the upper-limb joints is successfully tackled [8].”
From Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression (2007) · cites this paper as [8]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“These preliminary tests successfully showed the correct operation of the system and the capability of the system to access the workspace, without affecting the normal range of motion of the user [8].”
From Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression (2007) · cites this paper as [8]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters
de Leva, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00178-6 · Cited by 2,958 · cited 2×
“Biomechanical parameters per segment were obtained from Leva, [ 17 ].”
MethodImpedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929
Robotics: Control, Sensing, Vision, and Intelligence
Fu, K., González, R. C., & Lee, C. S. G. (1987) · Cited by 1,629
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 1×
“The main advantages of using gyroscopes are [12]: measures rotational motion – human motion is rotational about joints, they are not influenced by gravity,both frequency & magnitude information accurate down to DC (zero frequency), only a single integration is needed to obtain angular displacement, only a single deriv…”
BackgroundThe MANUS-HAND Dextrous Robotics Upper Limb Prosthesis: Mechanical and Manipulation Aspects
Pons, J. L., Rocon, E., Ceres, R., Reynaerts, D., Saro, B., Levin, S., & Van Moorleghem, W. (2004) · Autonomous Robots · doi:10.1023/b:auro.0000016862.38337.f1 · Cited by 266
Self-citationTremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 135
Pathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89 · cited 1×
“Basic electronics provide a band pass filter with a low cut-off frequency of 0.3 Hz and a higher cut-off frequency of 25 Hz. This frequency band was considered the most relevant to tremor applications after a thorough literature review, [ 13 ].”
MethodInfluentialSelf-citationDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 1×
“In the framework of the DRIFTS project, [6], WOTAS (Wearable Orthosis for Tremor Assesment and Supression) was presented with two main objectives: monitoring and diagnosis, and validation of non-grounded tremor reduction strategies.”
MethodSelf-citationDesigning to Miminize Discomfort
Goonetilleke, R. S. (1998) · Ergonomics in Design The Quarterly of Human Factors Applications · doi:10.1177/106480469800600304 · Cited by 37 · cited 1×
“Goonetilleke show in its work that there should be a threshold in which it is better concentrate than distribute forces, [ 8 ].”
Background
Research works printed but not linked: 8
- zatsiorsky, 1990, Methods of determining mass-inertial characteristics of human body segments, Contemporary Problems of Biomechanics, 272
- rocon, 2004, On the use of ultrasonic motors in orthotic rehabilitation of pathologic tremor, Proc ACTUATOR 2004 Conf, 387
- moreno, 2004, Intelligent knee-ankle-foot orthosis: The gait project approach, Rehabilitation Sciences in the New Millenium - Challenge for Multidisciplinary Research, 271
- belda-lois, 2003, Tremor movement analysis techniques: An approach towards ambulatory systems, Assistive Technology Shaping the Future, 827
- kapandji, 1983, The Physiology of the Joints Upper Limb, 1
- 1993, Guides to the evaluation of permanent impaired
- elble, 1990, Tremor
- gonzalez, 1999, A new portable method for the measurement of pressure-discomfort threshold (ptd) on the foot plant, Proceedings 4th Symposium on Footwear Biomechanics Canmore
Cited by
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Self-citationActive Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316
“There are a variety of active devices that target a specific disability or weakness in a particular joint of the leg [10], [11], [12], [13].”
BackgroundGravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W.-L., Scholz, J., & Rudolph, K. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
“There are a veriety of acti ve devices that target a particular disability or weakness, an d by repetitive motion try to regain the lost capability ([ 7 ], [8], [9], [10], [11]).”
BackgroundMechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
“[46] Elbow and wrist joints and forearm motion 03 Continuous current motors Gear drive Tremor Assessment and Suppression”
Background
Metadata
- Authors
- Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J.
- Affiliations
- Consejo Superior de Investigaciones Científicas (ES)
- ORCID
- Pons, J.L.
- Venue
- Proceedings of the 2005 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2006-01-18
- Pages
- 2271-2276
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W1550599557
- Cited by
- 87
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 6 · 2020: 5 · 2019: 2 · 2018: 6 · 2017: 4 · 2016: 3 · 2015: 6 · 2014: 2 · 2013: 3 · 2012: 8
- FWCI
- 15.48
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- wearable exoskeleton, upper limb exoskeleton, tremor suppression, tremor assessment, biomechanical loading, rehabilitation robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression. https://app.cochat.ai/papers/10.1109/robot.2005.1570451
- The paper
- Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006). Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression. Proceedings of the 2005 IEEE International Conference on Robotics and Automation. https://doi.org/10.1109/robot.2005.1570451
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.