Jointless structure and under-actuation mechanism for compact hand exoskeleton
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
It is important for a wearable robot to be compact and sufficiently light for use as an assistive device. Since human fingers are arranged in a row in dense space, the concept of traditional wearable robots using a rigid frame and a pin joint result in size and complexity problems. A structure without a conventional pin joint, called a jointless structure, has the potential to be used as a wearable robotic hand because the human skeleton and joint can replace the robot's conventional structure. Another way to reduce the weight of the system is to use under-actuation. Under-actuation enables adaptive grasping with less number of actuators for robotic hands. Differential mechanisms are widely used for multi-finger under-actuation; however, they require additional working space. We propose a design with a jointless structure and a novel under-actuation mechanism to reduce the size and weight of a hand exoskeleton. Using these concepts, we developed a prototype that weighs only 80 grams. To evaluate the prototype, fingertip force and blocked force are measured. Fingertip force is the force that can be applied by the finger of the hand exoskeleton on the object surface. The fingertip force is about 18 N when actuated by a tension force of 35 N from the motor. 18 N is sufficient for simple pinch motion in daily activities. Another factor related to performance of the under-actuation mechanism is blocked force, which is a force required to stop one finger while the other finger keeps on moving. It is measured to be 0.5 N, which is sufficiently small. With these experiments, the feasibility of the new hand exoskeleton has been shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“Wearable robots have been developed to assist in daily tasks [6], [7].”
Background
Cited by
Lee, L.-H., Braud, T., Zhou, P., Wang, L., Xu, D., Lin, Z., Kumar, A., Bermejo, C., & Hui, P. (2021) · arXiv · doi:10.48550/arxiv.2110.05352 · Cited by 1,088
“The existing works demonstrate various form factors exoskeletons [149], [150], gloves [151], [152], finger addendum [153], [154], smart wristbands [155], by considering numerous mechanisms including air-jets [156], ultrasounds [157]–[159], and laser [160], [161].”
BackgroundWearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473
Self-citationA biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
Metadata
- Authors
- In, H., Cho, K.-J., Kim, K., & Lee, B.
- Venue
- 2011 IEEE International Conference on Rehabilitation Robotics
- Publisher
- IEEE
- Published
- 2011-06
- Volume
- 2011
- Pages
- 1-6
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2144028337
- Cited by
- 111
- References
- 1
- FWCI
- 13.56
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.