The DOI matches its Crossref record.
EMG controlled soft robotic glove for assistance during activities of daily living
Abstract
This paper presents further developments, characterization and initial evaluation of a recently developed assistive soft robotic glove for individuals with hand pathologies. The glove technology utilizes a combination of elastomeric and inextensible materials to create soft actuators that conform to the user's hand and can generate sufficient hand closing force to assist with activities of daily living. User intent (i.e. desire to close or open hand) is detected by monitoring gross muscle activation signals with surface electromyography electrodes mounted on the user's forearm. In particular, we present an open-loop sEMG logic that distinguishes muscle contractions and feeds the information to a low-level fluidic pressure controller that regulates pressure in pre-selected groups of the glove's actuators. Experiments are conducted to determine the level of assistance provided by the glove by monitoring muscle effort and mapping the pressure distribution during a simple grasping task when the glove is worn. Lastly, quantitative and qualitative results are presented using the sEMG-controlled glove on a healthy participant and on a patient with muscular dystrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Self-citationOptoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
Soft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320
A Helping Hand: Soft Orthosis with Integrated Optical Strain Sensors and EMG Control
Zhao, H., Jalving, J., Huang, R., Knepper, R., Ruina, A., & Shepherd, R. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582216 · Cited by 191
Metadata
- Authors
- Polygerinos, P., Galloway, K. C., Sanan, S., Herman, M., & Walsh, C. J.
- Venue
- 2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
- Publisher
- IEEE
- Published
- 2015-08
- Pages
- 55-60
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W1666819333
- Cited by
- 175
- References
- 0
- FWCI
- 29.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EMG controlled soft robotic glove for assistance during activities of daily living. https://app.cochat.ai/papers/10.1109/icorr.2015.7281175
- The paper
- Polygerinos, P., Galloway, K. C., Sanan, S., Herman, M., & Walsh, C. J. (2015). EMG controlled soft robotic glove for assistance during activities of daily living. 2015 IEEE International Conference on Rehabilitation Robotics (ICORR). https://doi.org/10.1109/icorr.2015.7281175