EMG controlled soft robotic glove for assistance during activities of daily living
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper presents further developments, characterization and initial evaluation of a recently developed assistive soft robotic glove for individuals with hand pathologies. The glove technology utilizes a combination of elastomeric and inextensible materials to create soft actuators that conform to the user's hand and can generate sufficient hand closing force to assist with activities of daily living. User intent (i.e. desire to close or open hand) is detected by monitoring gross muscle activation signals with surface electromyography electrodes mounted on the user's forearm. In particular, we present an open-loop sEMG logic that distinguishes muscle contractions and feeds the information to a low-level fluidic pressure controller that regulates pressure in pre-selected groups of the glove's actuators. Experiments are conducted to determine the level of assistance provided by the glove by monitoring muscle effort and mapping the pressure distribution during a simple grasping task when the glove is worn. Lastly, quantitative and qualitative results are presented using the sEMG-controlled glove on a healthy participant and on a patient with muscular dystrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wolf, S. L., Winstein, C. J., Miller, J. P., Taub, E., Uswatte, G., Morris, D., Giuliani, C., Light, K. E., Nichols-Larsen, D., & EXCITE Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.17.2095 · Cited by 1,889
An objective and standardized test of hand function.
Jebsen, R. H., Taylor, N. F., Trieschmann, R. B., Trotter, M. J., & Howard, L. (1969) · PubMed · Cited by 1,705
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617 · cited 1×
“In further developments, multi-segment fiber-reinforced silicone actuators were introduced and shown to enable complex behaviors in which more than one motion can be programmed in series along the length of a single actuator and achieved by means of simple fluidic pressurizations [20], [22].”
BackgroundSelf-citationRobot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425 · cited 1×
“however, current practice is labor intensive, costly, and limited to clinical environments [3], [4].”
BackgroundTreatment-Induced Cortical Reorganization After Stroke in Humans
Liepert, J., Bauder, H., Miltner, W. H. R., Taub, E., & Weiller, C. (2000) · Stroke · doi:10.1161/01.str.31.6.1210 · Cited by 1,404 · cited 1×
“however, current practice is labor intensive, costly, and limited to clinical environments [3], [4].”
BackgroundA survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210 · cited 1×
“have been developed for rehabilitation purposes and consist of mostly of rigid exoskeleton designs that are often heavy and can be difficult to align with the biological joints of the hand [9], [10].”
BackgroundModeling of Soft Fiber-Reinforced Bending Actuators
Polygerinos, P., Wang, Z., Overvelde, J. T. B., Galloway, K. C., Wood, R. J., Bertoldi, K., & Walsh, C. J. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2428504 · Cited by 910 · cited 1×
“In previous work [21], the authors describe the design, analysis, and characterization of fluidic soft bending actuators that are constructed using a combination of elastomeric and inextensible materials.”
BackgroundSelf-citationStandards for Reporting EMG Data*
(2000) · Measurement of Human Locomotion · doi:10.1201/9781420036985.ax2 · Cited by 626
Robot-based hand motor therapy after stroke
Takahashi, C. D., Der-Yeghiaian, L., Le, V., Motiwala, R. R., & Cramer, S. C. (2008) · Brain · doi:10.1093/brain/awm311 · Cited by 624
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517 · cited 1×
“have been developed for rehabilitation purposes and consist of mostly of rigid exoskeleton designs that are often heavy and can be difficult to align with the biological joints of the hand [9], [10].”
Background
Cited by
Polygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Self-citationOptoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
Soft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320
Exploiting Textile Mechanical Anisotropy for Fabric-Based Pneumatic Actuators
Cappello, L., Galloway, K. C., Sanan, S., Wagner, D. A., Granberry, R., Engelhardt, S., Haufe, F. L., Peisner, J. D., & Walsh, C. J. (2018) · Soft Robotics · doi:10.1089/soro.2017.0076 · Cited by 215
“Compared to our previous work on fiber-reinforced soft actuators, 34 the proposed fabric-based actuators feature the following advantages: ease of integrating textiles with different properties (e.g., strength, abrasion resistance, conductance, and so on), textile-like flexibility when unpressurized,…”
Self-citationYap, H. K., Lim, J. H., Nasrallah, F., & Yeow, C.-H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00547 · Cited by 195
“…actuators with variable stiffness 200 5 160 MR-Glove/Yap et al., 2017 Fabric-reinforced actuators 180 5 120 Grip Glove/Maeder-York et al., 2014; Polygerinos et al., 2015a,b,c Fiber-reinforced actuators (Pneumatic or Hydraulic) <500 5 345 Nordina et al., 2016 Fiber-reinforced actuators N.A. 5…”
BackgroundMethodResultInfluentialA Helping Hand: Soft Orthosis with Integrated Optical Strain Sensors and EMG Control
Zhao, H., Jalving, J., Huang, R., Knepper, R., Ruina, A., & Shepherd, R. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582216 · Cited by 191
“This force output is similar to that of the fiber-reinforced soft actuators reported as hand assistive devices [9], [10], smaller than a cable-driven soft glove [7], and, at most, half of the theoretical upper-limit previously calculated.”
Moving toward Soft Robotics: A Decade Review of the Design of Hand Exoskeletons
Shahid, T., Gouwanda, D., Nurzaman, S. G., & Gopalai, A. A. (2018) · Biomimetics · doi:10.3390/biomimetics3030017 · Cited by 171
“However, design approaches used in Power-Assist glove [37], PneuGlove [36] and J-glove [39] in 2011 motivated researchers at the Wyss Institute [7,8] and NUS [9–17] to focus on overcoming this effect.”
BackgroundMethodInfluential
Metadata
- Authors
- Polygerinos, P., Galloway, K. C., Sanan, S., Herman, M., & Walsh, C. J.
- Venue
- 2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
- Publisher
- IEEE
- Published
- 2015-08
- Pages
- 55-60
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W1666819333
- Cited by
- 175
- References
- 19
- FWCI
- 29.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.