Modular Multilevel Converter topologies with DC-Short circuit current limitation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Demanding future applications in power transmission and drives like solar-thermic power plants and off-shore wind power require advanced converter systems. Modular Multilevel Converters are well adopted to these needs, owing to industrial scalability, high efficiency and fast dynamic controllability under transient and fault conditions including DC-Side faults. The respective features of the established concepts for the high power range (M2C) and of new concepts for the low power range (MHF) are explained.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Survey on Neutral-Point-Clamped Inverters
Rodriguez, J., Bernet, S., Steimer, P. K., & Lizama, I. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032430 · Cited by 1,813
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
New transformerless, scalable Modular Multilevel Converters for HVDC-transmission
Allebrod, S., Hamerski, R., & Marquardt, R. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591920 · Cited by 785 · cited 1×
“The number of paralled chips is adjusted according to the reqirements. Additional Data is given in [ 10 ].”
MethodSelf-citationMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773 · cited 1×
“Owing to these reasons, alternative topologies have been introduced, which enable the desired current limiting and voltage clamping functionality [ 11 ].”
MethodSelf-citationHVDC transmission systems using voltage sourced converters design and applications
Schettler, F., Huang, H., & Christl, N. (2002) · 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134) · doi:10.1109/pess.2000.867439 · Cited by 213
Multilevel Voltage-Sourced Converters for HVDC and FACTS Applications
Abdin, H., Aljabi, S., & Alnasseir, J. (2012) · Cited by 35
Modular converter systems for vehicle applications
Lambertz, L., Marquardt, R., & Mayer, A. (2010) · Emobility - Electrical Power Train · doi:10.1109/emobility.2010.5668055 · Cited by 26 · cited 1×
“At the right side, a new version – adapted to the requirements of the lower voltage range – is given (Modular High Frequency converter, MHF, see [4, 5, 6, 7]).”
Self-citationSingle shunt current sensing technique in three-level PWM inverter
Kim, S., Ha, J.-I., & Sul, S. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944454 · Cited by 19
Newly-constructed single-phase multistring multilevel inverter for fuel-cell microgrid
Liao, Y., & Lai, C. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944453 · Cited by 15
Research works printed but not linked: 5
- dorn, 0, Novel Voltage Sourced Converters for HVDC and FACTS Applications, Cigre Symposium Osaka 2008 Japan
- mayer, 0, Control concept of the Modular High Frequency – Converter for vehicle applications
- marquardt, 0, Modulares Stromrichterkonzept für Netzkopplungsanwendungen bei hohen Spannungen, ETG-Fachtagung
- marquardt, 0, Modular Multilevel Topologies State of the art and new developments
- marquardt, 0, New Concept for HighVoltage - Modular Multilevel Converter IEEE PESC 2004
Cited by
Items 301–400 of 451
Li, Y., Jones, E. A., & Wang, F. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803313 · Cited by 4
“Different SM topologies have also been proposed in the literature [7].”
BackgroundA comparative analysis of circulating current controllers for modular multilevel converters
Prasanna, P. S., Madichetty, S., & V., S. K. L. (2015) · IEEE India Conference · doi:10.1109/indicon.2015.7443169 · Cited by 4
Liu, Y., Si, Y., Zhang, Z., Liu, C., Wang, M., & Lei, Q. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3181048 · Cited by 4
Adam, G. P., Alsokhiry, F., Abdelsalam, I., Ahmed, K. H., & Al‐Turki, Y. A. (2018) · Electric Power Systems Research · doi:10.1016/j.epsr.2018.06.001 · Cited by 4
“Afterward, several multilevel converters were developed to overcome some of the main weaknesses of the MMCs such as: large footprint due to excessive use of cell capacitors, complex power circuit with many possibilities for malfunctions and high conversion losses should dc fault reverse blocking functionality is requi…”
MethodResearch of control strategies of MMC based on full bridge sub‐modules
Zhang, J., Jiang, C., & Chen, C. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8662 · Cited by 4
An improved submodule unified pulse modulation scheme for a hybrid modular multilevel converter
Lu, S., Li, K., Deng, X., Li, S., & Zhao, Z. (2017) · CES Transactions on Electrical Machines and Systems · doi:10.23919/tems.2017.8086112 · Cited by 4
Kang, F., & Song, S. (2020) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-020-00584-6 · Cited by 4
Fang, X., Hu, Z., Gao, C., Xiong, J., & Zhang, K. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479442 · Cited by 4
“Among the dc fault, the dc side pole-to-pole short circuit fault is most serious, leading to a rapid increase of dc fault current [2].”
BackgroundOn Systematic DC Fault-Ride-Through of Multi-terminal MMC-HVDC Grids
Niaki, S. H. A., Chen, Z., Bak‐Jensen, B., Sharifabadi, K., Liu, Z., & Hu, S. (2021) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec50034.2021.9548154 · Cited by 4
Suppression control strategy of MMC sub-module capacitor voltage in variable-frequency situation
Li, Z., Lei, B. W., Bai, J., Yang, B., & Zhu, D. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.12.055 · Cited by 4
AC–AC Modular Multilevel Converter—Hexverter
Arbugeri, C. A., Mussa, S. A., & Heldwein, M. L. (2022) · Energies · doi:10.3390/en15228519 · Cited by 4
An Enhanced Modular Multilevel Converter With Flexible Interruption Capability of DC-Side Fault
Mei, J., Zhu, P., Yan, L., Fan, G., Ge, R., & Wang, B. (2019) · IEEE Access · doi:10.1109/access.2019.2945965 · Cited by 4
“Compared with the FBSM, clamp double submodule (CDSM) reduces the number of devices required for unit voltage level [25], while the problem of structural coupling increases the difficulty of sub-module voltage equalization and operation control.”
MethodModular multilevel converter : submodule dimensioning, testing method, and topology innovation
Tang, Y. (2026) · Warwick Research Archive Portal (University of Warwick) · doi:10.82444/warw.33713899 · Cited by 4
Kurzschlussstromberechnung in Gleichstromnetzen der elektrischen Leistungsübertragung
Wasserrab, A. (2016) · Technischen Universität Darmstadt · doi:10.26083/tuprints-00005744 · Cited by 4
AC and DC systems interaction-opportunities and challenges of exchanging system services
Far, S., & Rashid, M. A. (2018) · NORA - Norwegian Open Research Archives · Cited by 4
Hillers, A. (2018) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000283386 · Cited by 4
An adaptive reclosing scheme for flexible DC grid based on residual voltage S-transformation
Dai, Y. T., Shu, H., An, N., Tang, Y., & Han, Y. (2025) · Scientific Reports · doi:10.1038/s41598-025-96571-w · Cited by 3
MOSFET parallel-connection of low-voltage MMC for LVDC distribution networks
Zhong, Y., Roscoe, N. M., Holliday, D., & Finney, S. J. (2016) · Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) · Cited by 3
Zhang, W., Guo, R., Shi, Y., Tang, Y., & Lin, Y. (2023) · Energies · doi:10.3390/en16217332 · Cited by 3
A novel triple capacitor multi-level submodule MMC topology with fault current clearing capability
Sun, Y., Jia, G., Hao, J., Lu, M., Li, G., Wang, Z., & Wu, X. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.109870 · Cited by 3
The unified model and optimal operation analysis for a modular multilevel converter
Huang, L., Yang, X., Zhang, F., Xu, P. F., Ma, X., Liu, T., Hao, X., & Liu, W. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7931199 · Cited by 3
“Several sub-module topologies of DC fault tolerant MMC have been reported in the literature [18-23].”
BackgroundModeling and analysis of DC voltage dynamics in modular multilevel converter
Wan, M., Hu, J., He, Z., & He, Z. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216780 · Cited by 3
“For DC fault self-cleaning, many other topologies for converter and SM with negative voltage generating capability have been proposed, such as the full-bridge sub-module (FBSM) based MMC [10], the clamp double sub-module (CDSM) based MMC [11], and the hybrid MMC [12-13] with the combination of the FBSMs and HBSMs and…”
BackgroundMaximum utilization of DC link voltage in grid connected hybrid modular multilevel converter
Kumar, A. D., Das, B., Kasari, P. R., & Chakrabarti, A. (2017) · doi:10.1109/iciteed.2017.8250465 · Cited by 3
A Parallel Connected Unfolding Bridge (PCUB) Multilevel Converter for HVDC Applications
Hassan, Z., Costabeber, A., Tardelli, F., Watson, A. J., & Clare, J. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927297 · Cited by 3
“Their main limitations where high switching losses, limited number of voltage levels and inadequate DC-side fault behaviour [8].”
BackgroundПлахтий, А. А., Нерубацкий, В. П., & Цыбульник, В. Р. (2019) · Bulletin of NTU Kharkiv Polytechnic Institute Series Electrical Machines and Electromechanical Energy Conversion · doi:10.20998/2409-9295.2019.20.06 · Cited by 3
Aljawary, Z. A., de Pablo, S., Herrero, L. C., & Martinez‐Rodrigo, F. (2020) · Energies · doi:10.3390/en13215585 · Cited by 3
“Modular converters, such as the MMC, reach any number of voltage levels by increasing or decreasing the number of SMs, and they offer various advantages over other multilevel topologies such as fault tolerant operation, easy to achieve capacitor voltage balance, low harmonic distortion and elimination of the bulky DC-…”
BackgroundBharath, G. V., & Gohil, G. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235331 · Cited by 3
“(i) 100% CDSM system (ii) 33.3% FLCCSM+66.6% HBSM system (iii) 100% SFBSM system Simulation parameters are given in Table.”
MethodInfluentialZhang, X., Zijuan, G., Huang, Y., Li, L., Weikuan, P., & Jian, C. (2021) · Frontiers in Energy Research · doi:10.3389/fenrg.2021.734797 · Cited by 3
“There is the half-bridge SM, the full-bridge SM, the clamp double SM, and three-level SM and so on (Marquardt, 2010; Marquardt, 2011).”
BackgroundAnsari, J. A., Liu, C., & Zheng, L. (2022) · National Conference on Electrical and Electronics Engineering (ELECO) · doi:10.1109/iceee55327.2022.9772520 · Cited by 3
“However, such systems require external reactive power for semiconductor switching and are not suitable for isolated systems [3].”
BackgroundRuseler, A., Lazzarin, T. B., & Barbi, I. (2015) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2015.7125191 · Cited by 3
“A solution that eliminates the dc bus capacitor (no surge and resonance currents) is found in [9]–[11] as Modular High Frequency Converters (MHF), which are suitable for electric vehicle applications.”
BackgroundBrueske, S., & Fuchs, F. W. (2014) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2014.6910941 · Cited by 3
“In [6, 11] modular inverter topologies are analysed for the application in electric vehicles.”
BackgroundA control strategy based on of modular multi-level converters with coupled inductances
Yuan, Y., & Zhu, B. (2014) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2014.6993495 · Cited by 3
“New MMC topologies are proposed in [8-10].”
BackgroundImproved control strategy of full-bridge modular multilevel converter
Adam, G. P. (2015) · IEEE Electrical Power and Energy Conference (EPEC) · doi:10.1109/epec.2015.7379971 · Cited by 3
“For example, the basic operational principle, modulation and capacitor voltage balancing of the MMC are discussed in [2-6].”
BackgroundWang, C., Lv, W., Lu, Y., Xu, F., & Qiu, P. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8696 · Cited by 3
Pole-to-Pole Fault Protection of Hybrid-MMC-based MVDC Distribution Systems
Huang, X., Qi, L., & Pan, J. (2018) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544634 · Cited by 3
Sano, K. (2020) · International Conference on Smart Grids and Energy Systems (SGES) · doi:10.1109/sges51519.2020.00082 · Cited by 3
“In the nonselective fault clearing strategy, the whole HVDC grid is deenergized by ac circuit breakers [9] or specific converters which have dc current blocking capability [10].”
BackgroundGoff, G. L. (2022) · theses.fr (ABES) · doi:10.70675/04995d87z5137z4d15z85c8z85ed99806044 · Cited by 3
Enomoto, M., Wakatsuki, K., & Sano, K. (2025) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2025.3649154 · Cited by 2
“Another methods are MMCs with fault blocking capability such as MMC which includes full-bridge submodule (FBSM) [9], [10], clump double submodule (CDSM)-based MMC [11], and other types of MMCs [12], [13].”
The Transition of China’s Power System
Lu, Z., & Zhu, G. (2021) · Springer eBooks · doi:10.1007/978-981-33-6100-3_4 · Cited by 2
Recognition and Analysis of Unexpected Modes of Modular Multilevel Converter
Fan, X., Qiu, D., Zhang, B., Chen, Y., Xie, F., & Yuan, C. (2021) · IEEE Access · doi:10.1109/access.2021.3090369 · Cited by 2
Karpagam, V., & Narmadhai, N. (2023) · Automatika · doi:10.1080/00051144.2023.2253067 · Cited by 2
“For normal operation, an IGBT is always on and coupled to two additional diodes in a clamp-double submodule (CDSM) [21].”
Ji, Y., Guo, P., & Liu, Q. (2024) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.13216 · Cited by 2
Design considerations for a voltage-boosting DC-AC Modular Multilevel Converter
Reed, J. K., Venkataramanan, G., Ramírez, D., & Soriano, C. G. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104447 · Cited by 2
“This is enabled by the use of many series-connected SMs, which allow series interleaving of the PWM switching, effectively multiplying the switching frequency FS by ns [6].”
BackgroundMethodA model-based controller for a three-phase grid-connected modular multilevel converter
Catzin-Contreras, G. A., Fernández, A., Escobar, G., & López-Sánchez, M. J. (2015) · IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC) · doi:10.1109/ropec.2015.7395153 · Cited by 2
“…following advantages: increased efficiency, by minimizing the semiconductor switching frequencies; drastically reduced passive filters at the alternating current (AC)-side; elimination of capacitors at the DC-link, and fast dynamic control of ACand DC-side under transient and fault conditions [6].”
BackgroundControlled transition bridge multilevel converter
Adam, G. P., Ahmed, K. H., Holliday, D., Finney, S. J., Burt, G., & Williams, B. W. (2016) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2016.7884445 · Cited by 2
Switching-Level Operation Analysis of MMC-based Back-to-Back Converter for HVDC Application
Hong, J.-W., Jeong, J.-K., Yoo, S.-H., Choi, J., & Han, B.-M. (2013) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2013.62.9.1240 · Cited by 2
“스위칭소자를 직렬로 결합하는 방식의 단점을 해결하고자 제안된 방식이 스위칭소자를 가지고 half-bridge 형태의 SM(sub-module)을 구성하고 이를 직렬로 결합한 MMC(modular multi-level converter)이다[3, 4].”
Hybrid modular multilevel converter with reduced three-level cells in HVDC transmission system
Li, R., Wu, J. L., Yao, L., Li, Y., & Williams, B. W. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512372 · Cited by 2
“Reference [5] proposes the clamp double (CD) sub-module to reduce the losses and block the dc fault.”
BackgroundTOV in SMs during MMC riding through zero DC voltage fault: analysis and suppression
Hu, J., Lu, M., & Lin, L. (2016) · The Journal of Engineering · doi:10.1049/joe.2016.0194 · Cited by 2
The modular multilevel DC converters for MVDC and HVDC applications
Xiang, X. (2018) · doi:10.25560/73139 · Cited by 2
Zhao, C., Gao, F., Li, Z., Wang, P., & Li, Y. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8926930 · Cited by 2
“Therefore, some other SM topologies have been proposed in order to address this issue including full-bridge SM (FBSM), clamp-double SM (CDSM), half-voltage clamp SM (HVCSM) and cross-connected fivelevel SM [5]-[7].”
BackgroundDaoud, M., Bahloul, M., & Khadem, S. (2020) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam48782.2020.9161942 · Cited by 2
“The limiting of DC fault currents in MMCs was initially discussed in [17].”
BackgroundProtection Measures for Modular Multilevel Converters in Case of DC Short-Circuit Faults
Geske, M., Basic, D., Jakob, R., Keller, C., & Bruckner, T. (2020) · European Conference on Power Electronics and Applications · doi:10.23919/epe20ecceeurope43536.2020.9215719 · Cited by 2
“This time-critical stage can take about 500 μs [7] and requires accurate and fast detection to maintain controllable fault currents.”
BackgroundMethodKung, S. H., Liu, D., Perera, C., Haji, M. M., Salmon, J., & Kish, G. J. (2020) · High Voltage · doi:10.1049/hve2.12061 · Cited by 2
“Full‐bridge SMs (FBSMs) can be adopted if dc side fault blocking is needed [40], at the expense of approximately doubling the semiconductor cost and the conduction losses with no other key operational benefits.”
BackgroundAn FBSM Capacitor Overvoltage Easing Method by Controlling the Arm Current Commutation of Hybrid MMC
Fang, X., Hu, Z., Xing, Y., Xiong, J., & Zhang, K. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479320 · Cited by 2
Active Current Transferring Modular Multilevel Converter With DC Fault Blocking Capacity
Liu, Z., Liu, H., Liu, C., Chen, Z., & Mei, J. (2021) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec50170.2021.9510835 · Cited by 2
Wu, J.-P., Guo, M., & Gao, W. (2021) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre52634.2021.9635404 · Cited by 2
“Therefore, the conduction losses of the proposed ITSM based MMC is lower than FBSM based MMC and UFBSM based MMC. VI. CONCLUSION In this paper, an ITSM topology and a protection scheme for ITSM based MMC are proposed.”
BackgroundInfluentialSingle-Phase Five-Level Multilevel Inverter Based on a Transistors Six-Pack Module
Garcia-Santiago, F. A., Rosas‐Caro, J. C., Valdez-Reséndiz, J. E., Mayo‐Maldonado, J. C., Valderrábano‐González, A., & Robles–Campos, H. R. (2022) · Energies · doi:10.3390/en15249321 · Cited by 2
Loss Minimization in Modular Multilevel Converter with Bypass Switch for HVDC Application
Varanasi, G., Sarkar, S., & Das, A. (2022) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet55524.2022.9909476 · Cited by 2
“SMs can be implemented with half bridge or full bridge or any other SM topologies [17].”
BackgroundOn Techno-economic Assessment of a Multi-terminal VSC-HVDC in AC Transmission Systems
Wang, F. (2013) · Chalmers Research (Chalmers University of Technology) · Cited by 2
Topology, modeling and analysis of bridge of bridge DC-AC and AC-DC power converters
Reed, J. K. (2014) · Cited by 2
State Space Modeling and Power Flow Analysis of Modular Multilevel Converters
Li, C. (2016) · VTechWorks (Virginia Tech) · Cited by 2
Review and Simulation of Voltage Source Converters for HVDC Grid Development
Alyami, H. (2018) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3mp4w33d · Cited by 2
Battery energy storage integration via DC/AC converter in grid connected wind turbines
Rekdal, K. (2018) · NORA - Norwegian Open Research Archives · Cited by 2
Fehr, H. (2020) · Qucosa (Saxon State and University Library Dresden) · Cited by 2
Guédon, D. (2022) · theses.fr (ABES) · doi:10.70675/fdfbbcd1z7c47z4154z86bdz51c3fe983331 · Cited by 2
Brüske, S. (2016) · MACAU: Open Access Repository of Kiel University · Cited by 2
Development of a HVDC grid protection strategy based on hybrid OHL and cable lines
Torwelle, P. (2021) · theses.fr (ABES) · doi:10.70675/e87300e0z49ebz4166za239z5947e3162841 · Cited by 2
Hybridation d'un poste de distribution HTA/BT : conception et dimensionnement
Reymond-Laruina, F. (2023) · theses.fr (ABES) · doi:10.70675/94309ba6zd0bcz49d6za43fz7cf69df7faf9 · Cited by 2
정재정 (2013) · Seoul National University Open Repository (Seoul National University) · Cited by 2
A Novel Protection Scheme for DC Distribution Network with Multi-terminal PV
Wang, C., Jia, K., He, Z. H. A. O., Li, Z., Li, W., & Liu, B. (2019) · IEEE International Conference on Electronic Information and Communication Technology (ICEICT) · doi:10.1109/iceict.2019.8846294 · Cited by 1
Negative-Sequence Current Control with a Hybrid Three-Level Modular Multilevel Converter
Bieber, L. M., Yoo, P., Wang, L., & Jatskevich, J. (2022) · IEEE Electrical Power and Energy Conference (EPEC) · doi:10.1109/epec56903.2022.10000117 · Cited by 1
RB-IGBT Based MMC Topologies with DC Fault Blocking Capability
Peng, C., & Li, R. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367885 · Cited by 1
“For example, in FBSM-based MMC system, when there is a dc side fault, the equivalent circuit in Loop 2 is shown in Fig.”
BackgroundMethodInfluentialYousofi‐Darmian, S., & Barakati, S. M. (2023) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-023-00621-w · Cited by 1
“The clamped-double SM includes two HBSM in series, one additional switch, and two diodes, providing lower loss than FBSM (Marquardt 2011).”
BackgroundInfluentialHigh-Voltage Direct Current Transmission Systems Based on Silicon Carbide MOSFETs
Li, Z. (2024) · Transactions on Computer Science and Intelligent Systems Research · doi:10.62051/1ffqyk92 · Cited by 1
“However, due to the use of PWM technology to control the gate switching frequency of IGBTs, multiple on and off PWMs are performed within a single cycle, resulting in high switching losses in IGBTs [9].”
Optimal control of devices loss distribution for hybrid MMC operating with a reduced DC-link voltage
Lu, M., Yang, J., Zhao, Y., & Liu, Z. (2025) · Electric Power Systems Research · doi:10.1016/j.epsr.2025.111817 · Cited by 1
Park, J., Kim, D.-J., Lee, S., & Cui, S. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3684833 · Cited by 1
“However, this modeling assumption may be inconsistent with practical systems because a DC-link capacitor is typically not installed in industrial HVDC projects to limit the DC-side short-circuit current [39].”
Protection Scheme for HVDC Converters to Limit Fault Current against Dc-Side Faults
Krishnakumari, M., Kumar, P., & Sujatha, P. (2017) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.21598004 · Cited by 1
Ruseler, A., Lazzarin, T. B., & Barbi, I. (2015) · Eletrônica de Potência · doi:10.18618/rep.2015.3.2545 · Cited by 1
“However, there is still considerable opportunity for new contributions and, recently, novel topologies have been proposed for drives [5], single–phase structures [6], electrical vehicles [7] and modular systems [8].”
BackgroundThe DC-fault Blocking Capability by a New Hybrid Multi-level Converter in HVDC Transmission
Kumar, I. A., & Ramanababu, K. (2016) · International Journal of Science and Engineering Applications · doi:10.7753/ijsea0505.1003 · Cited by 1
Frequency and voltage control in mixed AC and DC transmission networks
Spallarossa, C. E. (2015) · doi:10.25560/32154 · Cited by 1
Benchmarking of real-time simulation model of modular multilevel converter
Grégoire, L.-A., Wang, W., Sleiman, M., & Al‐Haddad, K. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8217123 · Cited by 1
“When it was first introduced [7] a half-bridge SM was presented, but since then, a variety of SMs has been proposed (full bridge, clamp-double, T-type, NPC, PUC) [6-9], offering various advantages.”
BackgroundA DC fault protection scheme for half-bridge sub-module based MMC-HVDC
Shen, F., Hu, Y., Wang, X., Chen, D., & Teng, Y. (2017) · 2017 China International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec.2017.8388510 · Cited by 1
“Develop a converter with fault clearing capability So far, as typified by the full bridge sub-module based MMC and embedded dual sub-module based MMC [4], [5], after the occurrence of DC fault, the sub-module capacitor is applied to the fault current loop with a reverse polarity so as to eliminate the fault current.”
MethodA Control Scheme of Multi-Terminal DC Transmission System Based on MMC
Yuan, B., Xue, B., & Zhang, Y. (2018) · IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC) · doi:10.1109/imcec.2018.8469243 · Cited by 1
Brief Introduction To Modular Multilevel Converters And Relative Concepts And Functionalities
Purkait, S. (2018) · i-manager s Journal on Digital Signal Processing · doi:10.26634/jdp.6.1.15157 · Cited by 1
Modular Multilevel Converter Based HVDC System Efficiency Evaluation Using Analytical Method
Mustafa, E., Khan, M. Y. A., Saleem, N., Nawaz, A., & Zafar, A. (2018) · International Conference on Power Generation Systems and Renewable Energy Technologies (PGSRET) · doi:10.1109/pgsret.2018.8686034 · Cited by 1
MMC New Type Sub Module Toplogy and Control
Zhang, J., Hu, Z., Cui, D., Tian, X., & Yin, X. (2019) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2019.8881071 · Cited by 1
A Novel Three-level Submodule for Modular Multilevel Converter with DC Fault Blocking Capability
Hou, W., Zhang, Z., He, R., & Huang, S. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921500 · Cited by 1
“Compared with submodules with dc fault capability described in [16-23], the 3LSMs possess faster speed, and the diodes need not to endure reverse voltage or tackle equalizing voltage of several ones.”
BackgroundInfluentialMeng, X., Han, J., Pfannschmidt, J., Wang, L., Li, W., & Bélanger, J. (2019) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm40551.2019.8973959 · Cited by 1
“full-bridge MMC, clamped-double submodule MMC [5], and alternate arm converter [6]).”
BackgroundParameter-Identification-Based Protection for Photovoltaic DC Power Plant
Jia, K., Zhu, R., Bi, T., Zhao, Q., Wang, C., Qiang, Y., & Li, W. (2019) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm40551.2019.8973471 · Cited by 1
“Flexible DC boosting and integration system can only withstand the DC bipolar fault current for a short period of time because of the fragility of power electronic device; thus, the modular multilevel converter (MMC) and the DC/DC convertors in it must block within several millisecond after faults [2].”
BackgroundShi, X., & Ma, J. (2020) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec48164.2020.9220729 · Cited by 1
Analysis of MMC Grounding Fault on hybrid UHVDC systems
Weihuang, H., Xu, S., Li, Y., & Hong, R. (2020) · International Conference on HVDC (HVDC) · doi:10.1109/hvdc50696.2020.9292677 · Cited by 1
Zhang, Z., Wang, C., Wang, Y., Jiang, R., Wei, Z., & Xu, T. Y. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479025 · Cited by 1
Bai, R., Zhao, B., Zhang, X., Wang, L., Yu, Z., & Zeng, R. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10860901 · Cited by 1
Parsa, S., & Abbaszadeh, K. (2025) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc65486.2025.10911957 · Cited by 1
Future Trends in DC-DC Conversion for Renewable Energy Systems
Gronfula, M. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1012305 · Cited by 1
Modular Multilevel Converters with Module-Level Energy Storage for Medium Voltage Applications
Novakovic, B. (2021) · UWM Digital Commons (University of Wisconsin–Milwaukee) · Cited by 1
High power modular converters for grid interface applications
Jankovic, M. (2017) · Nottingham ePrints (University of Nottingham) · Cited by 1
DC Fault Current Analysis and Control for Modular Multilevel Converters
Yu, J. (2016) · VTechWorks (Virginia Tech) · Cited by 1
Control and operation of offshore wind farms connected with diode rectifier HVDC systems
Yu, L. (2019) · STAX · doi:10.48730/cbyn-pz59 · Cited by 1
Turn-Off Voltage Sharing of Field-Stop IGBTs in Series Connection under Inductive Load Conditions
Zhang, X. (2016) · Cambridge University Engineering Department Publications Database · doi:10.17863/cam.62060 · Cited by 1
Metadata
- Authors
- Marquardt, R.
- Affiliations
- Universität der Bundeswehr München (DE)
- Corresponding author
- Marquardt, Rainer
- ORCID
- Marquardt, Rainer
- Venue
- 8th International Conference on Power Electronics - ECCE Asia
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 1425-1431
- OpenAlex
- W2160311820
- Cited by
- 413
- References
- 9
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 30 · 2020: 35 · 2019: 63 · 2018: 45 · 2017: 44 · 2016: 40 · 2015: 36 · 2014: 40 · 2013: 16 · 2012: 9
- FWCI
- 28.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, DC faults, converter topology, power transmission, drive, offshore wind energy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.