Demanding future applications in power transmission and drives like solar-thermic power plants and off-shore wind power require advanced converter systems. Modular Multilevel Converters are well adopted to these needs, owing to industrial scalability, high efficiency and fast dynamic controllability under transient and fault conditions including DC-Side faults. The respective features of the established concepts for the high power range (M2C) and of new concepts for the low power range (MHF) are explained.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Survey on Neutral-Point-Clamped Inverters
Rodriguez, J., Bernet, S., Steimer, P. K., & Lizama, I. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032430 · Cited by 1,813
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
New transformerless, scalable Modular Multilevel Converters for HVDC-transmission
Allebrod, S., Hamerski, R., & Marquardt, R. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591920 · Cited by 785 · cited 1×
“The number of paralled chips is adjusted according to the reqirements. Additional Data is given in [ 10 ].”
MethodSelf-citationMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773 · cited 1×
“Owing to these reasons, alternative topologies have been introduced, which enable the desired current limiting and voltage clamping functionality [ 11 ].”
MethodSelf-citationHVDC transmission systems using voltage sourced converters design and applications
Schettler, F., Huang, H., & Christl, N. (2002) · 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134) · doi:10.1109/pess.2000.867439 · Cited by 213
Multilevel Voltage-Sourced Converters for HVDC and FACTS Applications
Abdin, H., Aljabi, S., & Alnasseir, J. (2012) · Cited by 35
Modular converter systems for vehicle applications
Lambertz, L., Marquardt, R., & Mayer, A. (2010) · Emobility - Electrical Power Train · doi:10.1109/emobility.2010.5668055 · Cited by 26 · cited 1×
“At the right side, a new version – adapted to the requirements of the lower voltage range – is given (Modular High Frequency converter, MHF, see [4, 5, 6, 7]).”
Self-citationSingle shunt current sensing technique in three-level PWM inverter
Kim, S., Ha, J.-I., & Sul, S. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944454 · Cited by 19
Newly-constructed single-phase multistring multilevel inverter for fuel-cell microgrid
Liao, Y., & Lai, C. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944453 · Cited by 15
Research works printed but not linked: 5
- dorn, 0, Novel Voltage Sourced Converters for HVDC and FACTS Applications, Cigre Symposium Osaka 2008 Japan
- mayer, 0, Control concept of the Modular High Frequency – Converter for vehicle applications
- marquardt, 0, Modulares Stromrichterkonzept für Netzkopplungsanwendungen bei hohen Spannungen, ETG-Fachtagung
- marquardt, 0, Modular Multilevel Topologies State of the art and new developments
- marquardt, 0, New Concept for HighVoltage - Modular Multilevel Converter IEEE PESC 2004
Cited by
Items 401–451 of 451
Estudo e aplicação de Transformador de Estado Sólido para redes de distribuição
Marques, M. J. M. R. D. M. (2020) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/b256-ky34 · Cited by 1
Aljawary, Z. A. (2022) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/55033 · Cited by 1
Lara Jiménez, M. M. (2018) · Repositorio del Tecnológico de Monterrey (Tecnológico de Monterrey) · Cited by 1
비대칭 혼합 MMC 토폴로지를 이용한 양극 HVDC 시스템의 분석 및 제어
정재정 (2017) · Seoul National University Open Repository (Seoul National University) · Cited by 1
Redundancy Module Operation Analysis of MMC using Scaled Hardware Model
Yoo, S.-H., Shin, E.-S., Choi, J., & Han, B.-M. (2014) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2014.63.8.1046
Benefits of Operating a Four Terminal HVDC Network with a Normally Open Point
Sheridan, C. E., Merlin, M., & Green, T. C. (2015)
DC current suppression circuit in HVDC power transmission system
Kim, S., Jung, J.-J., Cui, S., & Sul, S. (2014) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2014.6910960
“The double-clamp module connects two half-bridge modules in series with one IGBT and two diodes [5].”
BackgroundDC fault ride through operation of a full-bridge MMC converter
Feng, Y. (2016) · Nottingham ePrints (University of Nottingham)
Stratégie de protection à sélectivité totale pour réseaux MTDC
Auran, G., Raison, B., Descloux, J., & Nguefeu, S. (2016) · HAL
Reliability Analysis of Modular Multilevel Converter for Offshore Wind Power Transmission Systems
Liu, H. (2016) · VBN Forskningsportal (Aalborg Universitet) · doi:10.5278/vbn.phd.engsci.00105
“Depending on how the arms are configured, different MMC topologies can be derived like the single-star, single-delta and double-star configurations [55, 56].”
BackgroundMethodThe terminal HVDC model and DC voltage slope control strategy based on MMC
Shi, S.-S., Zhang, X., Liu, B., & Zhang, G.-Q. (2017) · Annual International Conference on Electronics, Electrical Engineering and Information Science (EEEIS) · doi:10.2991/eeeis-16.2017.33
“MMC Basic Operation Principle MMC is composed of a plurality of cascaded modules (Sub-Module, SM), these sub modules can be half bridge or full bridge (H bridge) [10,11], the MMC half bridge topology is shown in figure 1.”
BackgroundIntegrated control of offshore wind farms and HVDC links with MML converters
Vidal-Albalate, R. (2017) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · doi:10.6035/14031.2017.163969
Optimal design of wind turbine converters using advanced power semiconductor materials
Reddy, N. P. (2018) · NVA (Nasjonalt vitenarkiv)
Investigation of Traditional and Hybrid Modular Multilevel Converters under Various Voltage Levels
Kurtoğlu, M., Arslan, A. O., Eroğlu, F., & Vural, A. M. (2018) · International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) · doi:10.1109/ismsit.2018.8567314
Zhao, C., Xu, F., Li, Z., Wang, P., & Li, Y. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590609
“However, the conventional half-bridge SM (HBSM) based MMC (HB-MMC), which is widely applied in practical projects, reveal weakness to dc short circuit faults as it can not generate negative voltages in arms [5].”
BackgroundWang, W., Ma, K., & Cai, X. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590565
“As MMCs usually consist of a large number of SMs, one of the potential challenges associated with the safe and reliable operation of MMCs is the balancing control of the floating capacitor voltages in SMs [1]-[2].”
BackgroundXu, F., Lu, Y., Qiu, P., Xuan, X., Yu, H., & Liu, G. (2018) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2018.8602150
“While for F-MMC, since the number of SMs is not large, the phase-shifted carrier-based pulse-width modulation (PSC-PWM) [17] is used to take the harmonic into account.”
MethodInfluentialModular Multilevel Converter-Based Hvdc Transmission Systems
Hussein, N. (2018) · Qatar University QSpace (Qatar University)
Improved operation and design of modular multi-level converters through harmonic injection
Elayeb, S. (2019) · Nottingham ePrints (University of Nottingham)
Wei, C., Yankun, Z., Jinglan, Z., Yuan, Z., Hu, Y., Li, X., Peng, L., Dang-guo, X., Ma, X., & Zhang, C. (2019) · International Conference on Intelligent Green Building and Smart Grid · doi:10.1109/igbsg.2019.8886234
“Most existing MMC technologies use a half-bridge sub-module topology[4].”
MethodPower Loss and Efficiency Analysis of Clamp Double Sub Module using Analytical and Numerical Method
Mustafa, E., Saleem, N., Nawaz, A., Malik, A., & Khan, M. Y. A. (2019) · International Conference on Electrical, Communication, and Computer Engineering (ICECCE) · doi:10.1109/icecce47252.2019.8940800
“It is important to note here that to avoid shortening of the sub-module, IGBTs in one pair must not be in the on state at the same period [4, 13].”
BackgroundUkil, A., Yeap, Y. M., & Satpathi, K. (2020) · Power systems · doi:10.1007/978-981-15-2977-1_10
Restart Control Strategy for the MMC-Based HVDC System
Li, B., & He, J. (2020) · Power systems · doi:10.1007/978-981-15-6644-8_9
Leterme, W., Judge, P. D., & Green, T. C. (2020) · European Conference on Power Electronics and Applications · doi:10.23919/epe20ecceeurope43536.2020.9215805
Xu, F., Huang, X., Lu, C., & Lu, Y. (2020) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec50848.2020.9351302
“What’s more, the existing DC distribution projects that have been put into operation, such as Hangzhou Dajiangdong DC distribution network demonstration project, Suzhou AC-DC hybrid active distribution network project, adopt the symmetrical monopole structure with high technical maturity [8-10].”
Multilevel Converter based System Fault Analysis
Bhaskar, M. (2021) · Türk bilgisayar ve matematik eğitimi dergisi · doi:10.17762/turcomat.v12i5.1468
“Right now, thought of the MMC system proposed [8, 9] independent for the secluded plan having a low exchanging recurrence and well force quality [10].”
BackgroundFast Energy Equivalent Modeling of MMC Based on Controlled Source
Li, J., Chen, X., Chen, D., Ye, X., Guo, J., & Cheng, Z. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/769/4/042102
An AC Current-Limiting Strategy for the Improved Modular Multilevel Converter
Fang, X., Hu, Z., Gao, C., Xiong, J., & Zhang, K. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479308
Rasheed, S., Kumar, C. P., & Shankar, M. M. (2020) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.b2067.1210220
Energy Balancing between HBSMs and FBSMs of Hybrid MMC during Fault Blocking
Xing, Y., Wang, D., Gao, C., Hu, Z., Xiong, J., & Zhang, K. (2021) · IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia) · doi:10.1109/icpsasia52756.2021.9621454
Chaudhuri, N. R., Chaudhuri, B., Majumder, R., & Yazdani, A. (2014) · Wiley eBooks · doi:10.1002/9781118960486.refs
Protection Under DC Short‐Circuit Fault in HVDC System
Deng, F., Liu, C., & Chen, Z. (2023) · Wiley eBooks · doi:10.1002/9781119875635.ch7
An Advanced Average-Value Model of Full-Bridge MMC Station with Blocking Capability
Li, W., Zhao, J., Sun, Q., Zhu, X., & Jia, Y. (2023) · International Conference on Energy, Electrical and Power Engineering (CEEPE) · doi:10.1109/ceepe58418.2023.10165987
“German scholar Rainer Marquardt, who is also the founder of MMC, divided MMC topology into three types [2]: half-bridge MMC (HB-MMC) which lacks dc fault ride-through capability but requires fewer power semiconductor devices and has low losses; full-bridge MMC (FB-MMC) and double-clamp MMC (DC-MMC) with dc fault ride-…”
BackgroundA Self Blocking Hybrid Submodule With Capacitor Voltage Self-balancing Capability
Zhao, Y., Liu, X., Zheng, K., & Zhang, J. (2023) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes59999.2023.10400104
“In [4], full bridge SM (FBSM) was proposed, which has DC fault blocking capability, but its device costs are high.”
BackgroundA Hardware and Software Combined PTG Fault Traversal Control Strategy of MMC
Li, J., Pei, X., Zhang, Y., Zhou, P., & Yao, L. (2024) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec60922.2024.10583268
PROTECTION STRATEGY FOR MULTI-TERMINAL HB-MMC BASED HVDC GRIDS
Niaki, S. H. A. (2024) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau7747043651
Parsa, S., & Abbaszadeh, K. (2024) · doi:10.1109/icemd64575.2024.10963590
“These challenges highlight the demand for MMC innovations that enhance voltage modulation, support bidirectional flow, and offer robust fault management, particularly in medium-voltage systems where stability is essential [7], [8].”
Qi, H., Zhang, G., Liu, Y., Ni, Y., Chen, M., & Liu, Y. (2024) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei264398.2024.10991836
“The CDSM and the full bridge sub-module with DC fault current blocking capability are provided[3-4].”
Future Power Generation Applications, Challenges, and Solutions
Zellagui, M. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1008582
DC Fault Ride-Through Control of a Hexagonal Hybrid-Frequency Solid-State Transformer
Yang, X., Sun, Y., Yan, Y., Teixeira, C., & Hu, H. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11260050
“The work in [7] proposed a clamped-diode submodule (CDSM)-based MMC introduces additional power devices and increases system losses.”
Contigency analysis and protection schemes of HVDC grids
Rosenje, A. O. (2024) · UPCommons institutional repository (Universitat Politècnica de Catalunya)
Wang, Z. (2022) · Mspace (University of Manitoba)
Analysis of AC/DC Fault Characteristics and DC-Side Fault Self-clearing Principle of MMC
Xu, Z. G., Xiao, H., & Zhang, Z. (2025) · Springer eBooks · doi:10.1007/978-981-95-0861-7_7
An Improved HB-MMC with the Active Capability of Handling DC Side Short-Circuit Faults
Xue, Y., Zhao, F., Zhao, D., Li, M., Huang, L., Chen, X., Shao, T., & Lin, Z. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-4286-4_34
Research on Bipolar Short-Circuit Fault Current Clearing Method for T-type DC Transformers
Zhang, Z., Yali, L., Zhiguang, L., Weihua, D., Yuanzhen, L., & Tingting, C. (2025) · International Conference on Smart Grid and Energy (ICSGE) · doi:10.1109/icsge68440.2025.11441949
“Due to its structural, operational, and control similarities with HBSM, FBSM is more widely accepted in practical applications[7][8][9][10]. remains insufficient.”
大電力FTF システムへの応用のためのモジュラー・マルチレベル二重スター・チョッパセル形変換器の研究
Sasongko, F. (2016) · Institutional Repositories DataBase (IRDB)
A Multilevel Modular Converter with Auxiliary Circuit Breaker for DC Fault Protection
Wu, J., Liu, C., Xu, Z., Li, W., Sheng, Y., & Zhang, G. (2026) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec69682.2026.11571851
“MMCs employing novel submodule topologies are proposed to deal with the dc fault, such as full-bridge submodule (FBSM) [5], clamp double submodule (CDSM) [6], unipolar voltage full-bridge submodule (UFBSM) [7], [8] and three-level submodule [9], which can inject reverse voltage to quickly block dc…”
Zhang, Q., Cheng, J., Zhang, J., Liang, Z., Yuan, P., Liu, W., Wang, Q., & He, T. (2026) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.70343
Kim, S. (2014) · Seoul National University Open Repository (Seoul National University)
Liu, X., Yang, X., & Luo, W. (2026) · Scientific Reports · doi:10.1038/s41598-026-69330-8
Metadata
- Authors
- Marquardt, R.
- Affiliations
- Universität der Bundeswehr München (DE)
- Corresponding author
- Marquardt, Rainer
- ORCID
- Marquardt, Rainer
- Venue
- 8th International Conference on Power Electronics - ECCE Asia
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 1425-1431
- OpenAlex
- W2160311820
- Cited by
- 413
- References
- 9
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 30 · 2020: 35 · 2019: 63 · 2018: 45 · 2017: 44 · 2016: 40 · 2015: 36 · 2014: 40 · 2013: 16 · 2012: 9
- FWCI
- 28.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, DC faults, converter topology, power transmission, drive, offshore wind energy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.