Modular Multilevel Converter topologies with DC-Short circuit current limitation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Demanding future applications in power transmission and drives like solar-thermic power plants and off-shore wind power require advanced converter systems. Modular Multilevel Converters are well adopted to these needs, owing to industrial scalability, high efficiency and fast dynamic controllability under transient and fault conditions including DC-Side faults. The respective features of the established concepts for the high power range (M2C) and of new concepts for the low power range (MHF) are explained.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Survey on Neutral-Point-Clamped Inverters
Rodriguez, J., Bernet, S., Steimer, P. K., & Lizama, I. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032430 · Cited by 1,813
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
New transformerless, scalable Modular Multilevel Converters for HVDC-transmission
Allebrod, S., Hamerski, R., & Marquardt, R. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591920 · Cited by 785 · cited 1×
“The number of paralled chips is adjusted according to the reqirements. Additional Data is given in [ 10 ].”
MethodSelf-citationMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773 · cited 1×
“Owing to these reasons, alternative topologies have been introduced, which enable the desired current limiting and voltage clamping functionality [ 11 ].”
MethodSelf-citationHVDC transmission systems using voltage sourced converters design and applications
Schettler, F., Huang, H., & Christl, N. (2002) · 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134) · doi:10.1109/pess.2000.867439 · Cited by 213
Multilevel Voltage-Sourced Converters for HVDC and FACTS Applications
Abdin, H., Aljabi, S., & Alnasseir, J. (2012) · Cited by 35
Modular converter systems for vehicle applications
Lambertz, L., Marquardt, R., & Mayer, A. (2010) · Emobility - Electrical Power Train · doi:10.1109/emobility.2010.5668055 · Cited by 26 · cited 1×
“At the right side, a new version – adapted to the requirements of the lower voltage range – is given (Modular High Frequency converter, MHF, see [4, 5, 6, 7]).”
Self-citationSingle shunt current sensing technique in three-level PWM inverter
Kim, S., Ha, J.-I., & Sul, S. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944454 · Cited by 19
Newly-constructed single-phase multistring multilevel inverter for fuel-cell microgrid
Liao, Y., & Lai, C. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944453 · Cited by 15
Research works printed but not linked: 5
- dorn, 0, Novel Voltage Sourced Converters for HVDC and FACTS Applications, Cigre Symposium Osaka 2008 Japan
- mayer, 0, Control concept of the Modular High Frequency – Converter for vehicle applications
- marquardt, 0, Modulares Stromrichterkonzept für Netzkopplungsanwendungen bei hohen Spannungen, ETG-Fachtagung
- marquardt, 0, Modular Multilevel Topologies State of the art and new developments
- marquardt, 0, New Concept for HighVoltage - Modular Multilevel Converter IEEE PESC 2004
Cited by
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
“critical challenge which corresponds to the HVDC application requirements is the internal and the external fault tolerance of the converter [114].”
BackgroundDesign and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
Protection of Nonpermanent Faults on DC Overhead Lines in MMC-Based HVDC Systems
Li, X., Song, Q., Liu, W., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2226249 · Cited by 402
“A double-clamp submodule (DCSM) proposed in [5] and [18] reduces the required number of power semiconductors.”
BackgroundThe Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability
Merlin, M. M. C., Green, T. C., Mitcheson, P. D., Trainer, D. R., Critchley, R., Crookes, W., & Hassan, F. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2282171 · Cited by 402
“In [17], the double-clamped submodule (DCS)was”
Isolated DC/DC Structure Based on Modular Multilevel Converter
Kenzelmann, S., Rufer, A., Dujic, D., Canales, F., & de Novaes, Y. R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2305976 · Cited by 371
“Lately multiterminal dc grids using MMC have been proposed [27]–[29]; however, even in this configuration the MMC is still mainly used to interface a low-frequency ac source (50 or 60 Hz) with a dc line.”
MethodHybrid Design of Modular Multilevel Converters for HVDC Systems Based on Various Submodule Circuits
Qin, J., Saeedifard, M., Rockhill, A., & Zhou, R. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2351794 · Cited by 358
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“with the MMC itself, operating as a voltage source has been proposed to clear the dc fault [118].”
BackgroundA review of LCC-HVDC and VSC-HVDC technologies and applications
Oni, O. E., Davidson, I. E. A., & Mbangula, K. N. I. (2016) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2016.7555677 · Cited by 242
“Another major setback is that a high level of electromagnetic interference occur when two-level converter is used for a high voltage DC systems [32].”
BackgroundMerlin, M. M. C., & Green, T. C. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0328 · Cited by 216
“Some cell variants exist, such as the Double Clamped Submodule (DCS) [16], which offer compromises between power losses, device count and negative voltage generation capability.”
BackgroundCui, S., & Sul, S.-K. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2513426 · Cited by 210
“2(c) has been proposed to handle the pole-to-pole short-circuit faults [13].”
BackgroundReliability Analysis and Redundancy Configuration of MMC With Hybrid Submodule Topologies
Xu, J., Zhao, P., & Zhao, C. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2444877 · Cited by 179
“2, respectively, represents the half-bridge SM (HBSM) [12], the fullbridge SM (FBSM) [13], the clamp double SM (CDSM) [14], the clamp single SM (CSSM) [15], and the improved hybrid SM (IHSM) [16].”
Nguyen, T. H., Hosani, K. A., Moursi, M. S. E., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2862247 · Cited by 173
“4) MMC Based on CDSMs: An alternative SM was proposed in [34] called clamped double SM as shown in Fig.”
Continuous Operation of Radial Multiterminal HVDC Systems Under DC Fault
Li, R., Xu, L., Holliday, D., Page, F., Finney, S. J., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2471089 · Cited by 171
Modular Multilevel Converter With Series and Parallel Module Connectivity: Topology and Control
Goetz, S. M., Peterchev, A. V., & Weyh, T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310225 · Cited by 171
“, in power line converters, with respect to both ac and dc terminals [54].”
BackgroundResearch and application on multi‐terminal and DC grids based on VSC‐HVDC technology in China
An, T., Tang, G., & Wang, W. (2017) · High Voltage · doi:10.1049/hve.2017.0010 · Cited by 168
The Research of SM Topology With DC Fault Tolerance in MMC-HVDC
Zhang, J., & Zhao, C. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2399412 · Cited by 167
Adam, G. P., & Davidson, I. E. A. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2394387 · Cited by 167
“References [4, 5] have shown that the threelevel and five-level cells MMCs presented in [23, 36-38] offer dc fault limiting feature, with similar level of semiconductor losses and converter footprint as the mixed cells MMC.”
BackgroundImpacts of Three MMC-HVDC Configurations on AC System Stability Under DC Line Faults
Tang, G., Xu, Z., & Zhou, Y. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2315666 · Cited by 164
Satpathi, K., Ukil, A., & Pou, J. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2788199 · Cited by 137
Merlin, M. M. C., Soto-Sanchez, D., Judge, P. D., Chaffey, G., Clemow, P., Green, T. C., Trainer, D. R., & Dyke, K. J. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2723948 · Cited by 142
Xue, Y., & Xu, Z. G. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2352313 · Cited by 142
“A new breed of MMC adopting clamp double submodules (CDSM-MMC) was highlighted most recently [17], [18], achieving dc fault handling capability with just a few additions of semiconductor devices.”
BackgroundModular Multilevel Converters: State of the Art and Future Progress
Marquardt, R. (2018) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2018.2873496 · Cited by 139
“clamp-Double sMs The clamp-double SM (Figure 2) has been introduced in [6] and [7] to enable electronic over current protection under dc short circuit conditions and to reduce power loss compared to FB SMs.”
BackgroundMethodSelf-citationModular Multilevel Converters: Control and Applications
Martinez‐Rodrigo, F., Ramírez, D., Rey‐Boué, A. B., de Pablo, S., & Herrero, L. C. (2017) · Energies · doi:10.3390/en10111709 · Cited by 141
“SM topologies used to reduce DC short-circuits: (a) double clamp submodule; (b) topology with a thyristor at the SM input; and (c) topology with two thyristors at the SM input [5,17].”
InfluentialDarus, R., Pou, J., Konstantinou, G., Ceballos, S., Picas, R., & Agelidis, V. G. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2359005 · Cited by 131
“The circuit configuration of the MMC has been well described in the existing literature [3], [4].”
BackgroundLi, R., Adam, G. P., Holliday, D., Fletcher, J., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2389758 · Cited by 137
“When considering the number of devices in the conduction path and the current stresses per device, the proposed converter is expected to be competitive with the hybrid converters in [2], [14], [15], and [18].”
BackgroundTolbert, L. M., & Shi, X. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-811407-0.00013-1 · Cited by 136
A New Topology of Multilevel VSC Converter for a Hybrid HVDC Transmission System
Jung, J.-J., Cui, S., Lee, J.-H., & Sul, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2598368 · Cited by 135
“circulating current to balance the system [11].”
BackgroundAdam, G. P., & Williams, B. W. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2315833 · Cited by 133
“For more details on the modulation and cell capacitor voltage balancing adopted in this paper, refer to [41, 42, 44, 54-60].”
MethodA Hybrid Modular Multilevel Converter With Novel Three-Level Cells for DC Fault Blocking Capability
Li, R., Fletcher, J. E., Xu, L., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2423258 · Cited by 115
“of power devices in HB and TL cells [23], [24].”
BackgroundDC-side fault current management in extended multiterminal-HVDC-grids
Schmitt, D. R., Wang, Y., Weyh, T., & Marquardt, R. (2012) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd.2012.6198125 · Cited by 126
“Owing to these reasons, alternative topologies have been introduced, which enable the desired cut off and voltage clamping functionality [5].”
BackgroundSelf-citationFuture HVDC-grids employing modular multilevel converters and hybrid DC-breakers
Wang, Y., & Marquardt, R. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6631861 · Cited by 116
“3a) has been proposed for DC-side fault limitation by several authors [7][8].”
BackgroundMethodSelf-citationModéer, T., Nee, H., & Norrga, S. (2012) · EPE Journal · doi:10.1080/09398368.2012.11463829 · Cited by 120
Improved Design and Control of FBSM MMC With Boosted AC Voltage and Reduced DC Capacitance
Hu, J., Xiang, M., Lin, L., Lu, M., Zhu, J., & He, Z. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2739679 · Cited by 120
Recent Advancements in Submodule Topologies and Applications of MMC
Ali, S., Ling, Z., Tian, K., & Huang, Z. M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2990689 · Cited by 119
“3) Clamp-Double SM: Marquardt [15], [57] proposed an alternative SM of two series-connected HBSMs with dc fault current handling capability [58], [59] (Table 3; see Fig.”
BackgroundElserougi, A. A., Abdel-Khalik, A. S., Massoud, A. M., & Ahmed, S. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2325743 · Cited by 114
“In an MMC-HVDC system, the common dc-link capacitor is not utilized, which helps suppress the discharge current [14].”
BackgroundSelf-Start Control With Grouping Sequentially Precharge for the C-MMC-Based HVDC System
Xue, Y., Xu, Z. G., & Tang, G. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2279106 · Cited by 111
“Each arm of this converter employs many series-connected power modules, which can be implemented in three ways [2], [3], that is, half-bridge submodule (HBSM), full-bridge submodule (FBSM), and clamp double submodule (CDSM).”
BackgroundReview of protection and fault handling for a flexible DC grid
He, J., Chen, K., Li, M., Luo, Y., Liang, C., & Xu, Y. (2020) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-020-00157-9 · Cited by 110
“For example, the well-known full-bridge sub-module [66], and clamped double-sub-module [67], as shown in Fig.”
MethodComparison of Hierarchical Control and Distributed Control for Microgrid
Feng, X., Shekhar, A., Yang, F. Q., Hebner, R., & Bauer, P. (2017) · Electric Power Components and Systems · doi:10.1080/15325008.2017.1318982 · Cited by 103
Rana, R. A., Patel, S. A., Muthusamy, A., Lee, C. W., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics8111329 · Cited by 102
DC fault analysis for modular multilevel converter-based system
Li, B., He, J., Tian, J., Feng, Y., & Dong, Y. (2016) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-015-0174-3 · Cited by 102
“In this context, the idea of the MMC technique proposed in [8, 9] based on the modular design has a low switching frequency and better power quality [10].”
BackgroundZhao, C., Li, Y., Li, Z., Wang, P., Ma, X., & Luo, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2660532 · Cited by 96
“In [18], a new submodule provided in Fig.”
BackgroundA review of the protection for the multi-terminal VSC-HVDC grid
Li, B., He, J., Li, Y., & Li, B. (2019) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0136-2 · Cited by 98
Analysis of the Performance of MMC Under Fault Conditions in HVDC-Based Offshore Wind Farms
Vidal-Albalate, R., Beltrán, H., Rolán, A., Belenguer, E., Pena, R. S., & Blasco-Giménez, R. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2468171 · Cited by 97
Chen, L., Chen, H., Shu, Z., Zhang, G., Xia, T., & Ren, L. (2016) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2016.2595622 · Cited by 94
“In [11], [12], research scholars suggest improved topology schemes for HVDC converters to deal with DC fault, and there might be a compromising use of this solution when the performance behaviors, investment costs and engineering modifications should be taken into account.”
BackgroundDC Distribution Fault Analysis, Protection Solutions, and Example Implementations
Qi, L., Antoniazzi, A., & Raciti, L. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2825437 · Cited by 94
“The fault limiting capability of different types of converters for distribution systems can be found in [8], [22], [27], [30], and [33]–[36].”
BackgroundAn enhanced MMC topology with DC fault ride-through capability
Li, X., Liu, W., Song, Q., Rao, H., & Xu, S. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6700152 · Cited by 92
“Compared with full-bridge sub-module, double clamp submodule topology reduces the required number of power semiconductors [5], [20].”
BackgroundComparison of phase-shifted and level-shifted PWM in the modular multilevel converter
Darus, R., Konstantinou, G. S., Pou, J., Ceballos, S., & Agelidis, V. G. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6870039 · Cited by 93
A Submodule Implementation for Parallel Connection of Capacitors in Modular Multilevel Converters
Ilves, K., Taffner, F., Norrga, S., Antonopoulos, A., Harnefors, L., & Nee, H. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2345460 · Cited by 92
“Another type of submodule is the clamp-double submodule, which is suitable for handling dc short-circuit faults [4].”
BackgroundLu, M., Hu, J., Zeng, R., Li, W., & Lin, L. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2743780 · Cited by 92
“Among various topologies for MMC with DC-FRT capability [5]–[7], [9], [10], [16], [17], hybrid MMC containing half half-bridge submodules (HBSMs) and half fullbridge submodules (FBSMs) is a promising candidate in terms of cost, efficiency, and insulated-gate bipolar transistor (IGBT) series operation.”
BackgroundA Review of Modular Multilevel Converters for Stationary Applications
Wang, Y., Aksöz, A., Geury, T., Öztürk, S. B., Kıvanç, Ö. C., & Hegazy, O. (2020) · Applied Sciences · doi:10.3390/app10217719 · Cited by 91
“Multilevel submodule topologies: (a) neutral point clamped submodule (NPCSM); (b) flying capacitor submodule (FCSM); (c) cascaded half-bridge submodule (CHBSM); (d) stacked switched capacitor submodule (SSCSM); (e) clamp-double submodule (CDSM) type-Ⅰ; (f) CDSM type-Ⅱ; (g) hybrid submodules (HSM); (h) cross-connected…”
BackgroundInfluentialProtection and grounding methods in DC microgrids: Comprehensive review and analysis
Jayamaha, D. K. J. S., Lidula, N. W. A., & Rajapakse, A. D. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109631 · Cited by 90
Zhang, Y., Ravishankar, J., Fletcher, J., Li, R., & Han, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.108 · Cited by 90
Sima, W., Fu, Z., Yang, M., Yuan, T., Sun, P., Han, X. F., & Si, Y. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2878115 · Cited by 83
“Typical MMC topologies derived from the third concept include the full-bridge submodule [8], clamp double submodule [9], and series double submodule [10].”
BackgroundHybrid Multilevel Converters: Topologies, Evolutions and Verifications
Zhang, J., Xu, S., Din, Z., & Hu, X. (2019) · Energies · doi:10.3390/en12040615 · Cited by 79
“The hybrid sub-modules with asymmetrical DC fault blocking capability includes HSSM, clamp-double sub-module (CDSM) [58], diode-clamp sub-module (DCSM) [59], and switched capacitor sub-module (SCSM) [60].”
BackgroundInfluentialReview of fault diagnosis and fault-tolerant control for modular multilevel converter of HVDC
Liu, H., Loh, P. C., & Blaabjerg, F. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699310 · Cited by 79
“Moreover, the typical DC Short circuit was analyzed in [4] and the appearance of the surge and resonance currents would follow the DC short circuit.”
BackgroundA feasible coordination protection strategy for MMC-MTDC systems under DC faults
Wang, Y., Yuan, Z., Fu, J., Li, Y., & Zhao, Y. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.02.005 · Cited by 78
Li, Z., Ricardo Lizana, F., Sha, S., Yu, Z., Peterchev, A. V., & Goetz, S. M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2886147 · Cited by 77
An Improved Phase-Shifted Carrier Modulation Scheme for a Hybrid Modular Multilevel Converter
Lu, S., Yuan, L., Li, K., & Zhao, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2532386 · Cited by 77
“However, these modified SMs employ more power devices compared with the HBSMs-based MMC and suffer from the high conduction loss [14].”
MethodGoetz, S. M., Pfaeffl, M., Huber, J., Singer, M., Marquardt, R., & Weyh, T. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347016 · Cited by 73
“Additionally they act as a snubber circuitry [18], [19].”
BackgroundSelf-citationCui, S., Kim, S., Jung, J.-J., & Sul, S. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803370 · Cited by 72
Semi-full-bridge submodule for modular multilevel converters
Ilves, K., Bessegato, L., Harnefors, L., Norrga, S., & Nee, H. (2015) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7167913 · Cited by 70
“In order to alleviate this problem, the double-clamp submodule was proposed, which only increases the number of conducting elements by 25% [13], [14].”
BackgroundMitra, B., Chowdhury, B., & Manjrekar, M. D. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.5274 · Cited by 69
“Before such advancements in power electronics, VSC-HVDC grids were proposed based on a different converter topology, MMC [69, 70].”
Dimensioning and Modulation Index Selection for the Hybrid Modular Multilevel Converter
Judge, P. D., Chaffey, G. P., Merlin, M., Clemow, P., & Green, T. C. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2719103 · Cited by 67
“However, it remains weak to dc-side faults because of its inability to generate a negative voltage within its stacks of submodules (SMs) and, therefore, inability to control the fault current through the antiparallel diodes [2] of each SM.”
BackgroundIlves, K., Norrga, S., & Nee, H.-P. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6634324 · Cited by 61
“It is also possible to implement the submodules as clamp-double-submodules [14].”
BackgroundA Generalized Cross-Connected Submodule Structure for Hybrid Multilevel Converters
Mathew, E. C., Ghat, M. B., & Shukla, A. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2535117 · Cited by 63
“Among these, the modular multilevel converter (MMC) has become the most attractive choice because of its modularity, scalability, low dv/dt, low total harmonic distortion, and low switching losses along with the other advantages associated with VSC [7]–[9].”
BackgroundGhat, M. B., & Shukla, A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2751680 · Cited by 65
Rector Sizing Criterion for Continuous Operation of Meshed HB-MMC Based MTDC System Under DC Faults
Wang, Y., Wen, W., Zhang, C., Chen, Z., & Wang, C. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2833819 · Cited by 64
A novel start-up scheme for modular multilevel converter
Shi, K., Shen, F., Lv, D., Lin, P., Chen, M., & Xu, D. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342255 · Cited by 63
“There are several different topologies for the module [12].”
BackgroundThe impact of voltage-balancing control on switching frequency of the modular multilevel converter
Li, Y., Jones, E. A., & Wang, F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2448713 · Cited by 58
“Compared with the traditional two-level converter and three-level neutral-point diode-clamped converter, which were originally employed in these applications, the MMC has the following advantages as described in [4]–[8]: 1) no direct series of power switches; 2) higher efficiency; 3) less or no need for ac filters; an…”
MethodYang, W., Song, Q., Xu, S., Rao, H., & Liu, W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2722011 · Cited by 62
“To reduce the cost and power loss, a clamp-double submodule (CDSM) was proposed by inserting a clamped circuit between two HBSMs [5].”
BackgroundMethodModular Embedded Multilevel Converter for MV/HVDC Applications
Zhang, D., Dong, D., Datta, R., Rockhill, A., Lei, Q., & Garces, L. J. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2850891 · Cited by 61
A Modular Multilevel Converter Integrated With DC Circuit Breaker
Song, Q., Zeng, R., Yu, Z., Liu, W., Huang, Y., Yang, W., & Li, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2815550 · Cited by 60
“The parameters of the CDSM-MMC are designed in accordance with [4] and [5].”
BackgroundMethodHuang, X., Qi, L., & Pan, J. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2917360 · Cited by 60
“Several converter topologies have been proposed for dc fault current control/limiting functionality, such as the hybrid HB + thyristor MMC [17], the full-bridge (FB) MMC [18], [19], the clamp double MMC [18], [19], and the hybrid HB + FB MMC [20], [21].”
BackgroundA Novel Current-Commutation-Based FCL for the Flexible DC Grid
Li, B., He, J., Li, Y., Wen, W., & Li, B. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2924024 · Cited by 60
Tang, G., He, Z., & Pang, H. (2014) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-014-0045-3 · Cited by 59
Taha, T. A., Shalaby, M., Wahab, N. I. A., Zaynal, H. I., Hassan, M. K., Al-Sowayan, S. S., & Alawad, M. A. (2025) · Symmetry · doi:10.3390/sym17071010 · Cited by 57
Kurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2763 · Cited by 57
Jacobs, K., Heinig, S., Johannesson, D., Norrga, S., & Nee, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3049320 · Cited by 57
“for the unipolar FB (uFB) [149], [150], the clamped-double (CD) [151], [152], the half-voltage clamp (HVC) [153], [154], and the series-connected double (SCD) [155] SMs are shown in”
BackgroundTransient Current Waveform Similarity Based Protection for Flexible DC Distribution System
Jia, K., Wang, C., Bi, T., Zhu, R., & Xuan, Z. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2891457 · Cited by 56
“current to protect power electronic devices [5], [6].”
BackgroundZhao, C., Hu, Y., Luan, K., Xu, F., Li, Z., Wang, P., & Li, Y. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2906349 · Cited by 55
“One of the major issues for the conventional half-bridge submodule (HBSM)-based MMC (HB-MMC) is lack of dc short-circuit fault handling capability, and it is unsuitable for overhead-line occasions [9]–[11].”
BackgroundCurrent source modular multilevel converter for HVDC and FACTS
Liang, J., Nami, A., Dijkhuizen, F., Tenca, P., & Sastry, J. (2013) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2013.6634735 · Cited by 53
Application of multilevel full bridge converters in HVDC multiterminal systems
Petino, C., Heidemann, M., Eichhoff, D., Stumpe, M., Spahić, E., & Schettler, F. (2016) · IET Power Electronics · doi:10.1049/iet-pel.2015.0515 · Cited by 53
Wang, W., Ma, K., & Cai, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009272 · Cited by 53
“floating capacitor voltages in SMs, not only under steady states, but also under transients and complex operating conditions [1], [2].”
BackgroundCui, S., Kim, S., Jung, J.-J., & Sul, S. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803371 · Cited by 52
Chen, C., Adam, G. P., Finney, S. J., Fletcher, J., & Williams, B. W. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0513 · Cited by 52
Circulating current control and evaluation of carrier dispositions in modular multilevel converters
Darus, R., Pou, J., Konstantinou, G., Ceballos, S., & Agelidis, V. G. (2013) · 2013 IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia.2013.6579117 · Cited by 46
Protection of large partitioned MTDC Networks Using DC-DC converters and circuit breakers
Rahman, H., Xu, L., & Yao, L. (2016) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-016-0030-0 · Cited by 51
An improved modular multilevel converter with DC fault blocking capability
Zeng, R., Xu, L., & Yao, L. (2014) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2014.6938937 · Cited by 50
Li, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2747079 · Cited by 49
Modular Multilevel Converter With Embedded Energy Storage for Bidirectional Fault Isolation
Xu, Y., Zhang, Z., Wang, G., & Xu, Z. G. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3054022 · Cited by 48
A Review of LCC-HVDC and VSC-HVDC Technologies and Applications
Oni, O. E., Mbangula, K. N. I., & Davidson, I. E. A. (2016) · Transactions on Environment and Electrical Engineering · doi:10.22149/teee.v1i3.29 · Cited by 48
Transient Current Correlation Based Protection for DC Distribution System
Jia, K., Wang, C., Bi, T., Feng, T., & Zhu, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2952805 · Cited by 46
“To extinguish a fault current, a clamp double submodule modular multilevel converter (CDSM-MMC) topology with strong ability to block a fault current has been applied in numerous projects [15], [16].”
BackgroundXiao, H., Xu, Z. G., Tang, G., & Xue, Y. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0892 · Cited by 45
Darus, R., Pou, J., Konstantinou, G. S., Ceballos, S., & Agelidis, V. G. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0930 · Cited by 45
Wang, P., Zhang, X., Coventry, P. F., Zhang, R., & Zhou, L. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.10.003 · Cited by 45
A Novel DC Fault Ride-Through Scheme for MTDC Networks Connecting Large-Scale Wind Parks
Sanusi, W., Hosani, M. A., & Moursi, M. S. E. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2651025 · Cited by 44
“The second approach employs DC circuit breakers (DCCBs) on the DC terminals of half-bridge converters or full-bridge fault-tolerant multi-level converters with DC voltage reversing capability to interrupt fault current contribution from the AC side following a DC fault [10].”
BackgroundGeneralised protection strategy for HB‐MMC‐MTDC systems with RL‐FCL under DC faults
Wang, Y., Yuan, Z., Wen, W., Ji, Y., Fu, J., Li, Y., & Zhao, Y. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2016.1943 · Cited by 44
“When a DC fault occurs in half-bridge (HB)-based MMC, which is currently the preferred DC converter configuration due to its low power losses and costs [13], the insulated-gate bipolar transistors (IGBTs) are blocked for safety, the fault current continue to be fed from the AC grid to the DC side through the freewheel…”
BackgroundInfluentialInvestigation of a New Modular Multilevel Converter With DC Fault Blocking Capability
Hu, X., Zhang, J., Xu, S., & Jiang, Y. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2870845 · Cited by 43
“ule (HSSM) [8]–[10], hybrid-double submodule (HDSM) [11], clamp-double submodule (CDSM) [12], [13], diode-clamp submodule (DCSM) [14], [15], diode-clamp-double submodule”
Flexible Nearest Level Modulation for Modular Multilevel Converter
Wang, W., Ma, K., & Cai, X. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3089706 · Cited by 43
Metadata
- Authors
- Marquardt, R.
- Affiliations
- Universität der Bundeswehr München (DE)
- Corresponding author
- Marquardt, Rainer
- ORCID
- Marquardt, Rainer
- Venue
- 8th International Conference on Power Electronics - ECCE Asia
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 1425-1431
- OpenAlex
- W2160311820
- Cited by
- 413
- References
- 9
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 30 · 2020: 35 · 2019: 63 · 2018: 45 · 2017: 44 · 2016: 40 · 2015: 36 · 2014: 40 · 2013: 16 · 2012: 9
- FWCI
- 28.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, DC faults, converter topology, power transmission, drive, offshore wind energy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.