The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The DLR hand arm system
Open accessAbstract
An anthropomorphic hand arm system using variable stiffness actuation has been developed at DLR. It is aimed to reach its human archetype regarding size, weight and performance. The main focus of our development is put on robustness, dynamic performance and dexterity. Therefore, a paradigm change from impedance controlled, but mechanically stiff joints to robots using intrinsic variable compliance joints is carried out. Collisions of the rigid joint robot at high speeds with stiff objects induce the energy too fast for an active controller to prevent damages. In contrast, passively compliant robots are able to temporarily store energy. In this case the resulting internal forces applied to the robot structure and the drive trains are reduced. Furthermore, the energy storage allows to outperform the dynamics of stiff robots. The hand drives and the electronics are completely integrated within the forearm. Extremely miniaturized electronics have been developed to drive the 52 motors of the system and interface their sensors. Several variable stiffness actuation principles used in the arm joints and the hand are presented. The paper highlights the different requirements that they have to fulfill. A first test of the systems robustness and dynamics has been performed by driving nails with a grasped hammer and is demonstrated in the attached video.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The intelligent ASIMO: system overview and integration
Sakagami, Y., Watanabe, R., Aoyama, C., Matsunaga, S., Higaki, N., & Fujimura, K. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1041641 · Cited by 1,355
Albu-Schäffer, A., Ott, C., & Hirzinger, G. (2007) · The International Journal of Robotics Research · doi:10.1177/0278364907073776 · Cited by 815
Self-citationRobonaut 2 - The first humanoid robot in space
Diftler, M. A., Permenter, F. A., Hargrave, B. K., Platt, R., Savely, R. T., Ambrose, R. O., Mehling, J. S., Abdallah, M. E., Radford, N. A., Bridgwater, L. B., et al. (2011) · 2011 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2011.5979830 · Cited by 449
Anatomy, Descriptive and Surgical
(1883) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1883.02390080028013 · Cited by 423
Schiavi, R., Grioli, G., Sen, S., & Bicchi, A. (2008) · 2008 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2008.4543528 · Cited by 364
Design of human symbiotic robot TWENDY-ONE
Iwata, H., & Sugano, S. (2009) · 2009 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2009.5152702 · Cited by 258
Safety Evaluation of Physical Human-Robot Interaction via Crash-Testing
Haddadin, S., Albu-Schaeffer, A., & Hirzinger, G. (2007) · Robotics: Science and Systems III · doi:10.15607/rss.2007.iii.028 · Cited by 231
Self-citationDesign of components for programmable passive impedance
Laurin-Kovitz, K. F., Colgate, J. E., & Carnes, S. D. R. (2002) · Proceedings. 1991 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1991.131824 · Cited by 191
On joint design with intrinsic variable compliance: derivation of the DLR QA-Joint
Eiberger, O., Haddadin, S., Weis, M., Albu‐Schäffer, A., & Hirzinger, G. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509662 · Cited by 137
Self-citationKinematically optimal catching a flying ball with a hand-arm-system
Bauml, B., Wimbock, T., & Hirzinger, G. (2010) · 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2010.5651175 · Cited by 113
Self-citation
Cited by
Variable impedance actuators: A review
Vanderborght, B., Albu-Schaeffer, A., Bicchi, A., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M., Eiberger, O., Friedl, W., Ganesh, G., et al. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.06.009 · Cited by 1,008
Self-citationAdaptive synergies for the design and control of the Pisa/IIT SoftHand
Catalano, M. G., Grioli, G., Farnioli, E., Serio, A., Piazza, C., & Bicchi, A. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364913518998 · Cited by 673
Working Together: A Review on Safe Human-Robot Collaboration in Industrial Environments
Robla-Gomez, S., Becerra, V. M., Llata, J. R., Gonzalez-Sarabia, E., Torre-Ferrero, C., & Perez-Oria, J. (2017) · IEEE Access · doi:10.1109/access.2017.2773127 · Cited by 589
“With the development of systems for mechanical compliance, such as the VSA approach [80], [81], the SEA approach [82], decoupling the heavy motor inertia from the link inertia [53], [59], the use of lightweight materials such as light carbon fibres [68], [76], and the use of sensor skin based on capacitive sensing dev…”
MethodVariable Stiffness Actuators: Review on Design and Components
Wolf, S., Grioli, G., Eiberger, O., Friedl, W., Grebenstein, M., Hoppner, H., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M. G., et al. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2501019 · Cited by 459
Self-citationDesign and Control Considerations for High-Performance Series Elastic Actuators
Paine, N., Oh, S., & Sentis, L. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2270435 · Cited by 405
Piazza, C., Grioli, G., Catalano, M. G., & Bicchi, A. (2019) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105003 · Cited by 332
Borton, D., Micera, S., Millán, J. D. R., & Courtine, G. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005968 · Cited by 171
A bioelectric neural interface towards intuitive prosthetic control for amputees
Nguyen, A. T., Xu, J., Jiang, M., Luu, D. K., Wu, T., Tam, W.-K., Zhao, W., Drealan, M. W., Overstreet, C. K., Zhao, Q., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc3d3 · Cited by 52
Metadata
- Authors
- Grebenstein, M., Albu-Schaffer, A., Bahls, T., Chalon, M., Eiberger, O., Friedl, W., Gruber, R., Haddadin, S., Hagn, U., Haslinger, R., Hoppner, H., Jorg, S., Nickl, M., Nothhelfer, A., Petit, F., Reill, J., Seitz, N., Wimbock, T., Wolf, S., Wusthoff, T., & Hirzinger, G.
- Venue
- 2011 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 3175-3182
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2139086916
- Cited by
- 436
- References
- 13
- FWCI
- 83.41
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.