Learning by observation for surgical subtasks: Multilateral cutting of 3D viscoelastic and 2D Orthotropic Tissue Phantoms
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Automating repetitive surgical subtasks such as suturing, cutting and debridement can reduce surgeon fatigue and procedure times and facilitate supervised tele-surgery. Programming is difficult because human tissue is deformable and highly specular. Using the da Vinci Research Kit (DVRK) robotic surgical assistant, we explore a “Learning By Observation” (LBO) approach where we identify, segment, and parameterize motion sequences and sensor conditions to build a finite state machine (FSM) for each subtask. The robot then executes the FSM repeatedly to tune parameters and if necessary update the FSM structure. We evaluate the approach on two surgical subtasks: debridement of 3D Viscoelastic Tissue Phantoms (3d-DVTP), in which small target fragments are removed from a 3D viscoelastic tissue phantom; and Pattern Cutting of 2D Orthotropic Tissue Phantoms (2d-PCOTP), a step in the standard Fundamentals of Laparoscopic Surgery training suite, in which a specified circular area must be cut from a sheet of orthotropic tissue phantom. We describe the approach and physical experiments with repeatability of 96% for 50 trials of the 3d-DVTP subtask and 70% for 20 trials of the 2d-PCOTP subtask. A video is available at: http://j.mp/Robot-Surgery-Video-Oct-2014.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey of robot learning from demonstration
Argall, B. D., Chernova, S., Veloso, M., & Browning, B. (2009) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2008.10.024 · Cited by 3,227
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Towards automatic skill evaluation: Detection and segmentation of robot-assisted surgical motions
Lin, H. C., Shafran, I., Yuh, D., & Hager, G. D. (2006) · Computer Aided Surgery · doi:10.3109/10929080600989189 · Cited by 254 · cited 1×
“propose a “Language of Surgery” with “surgemes” analogous to phonemes [21, 30, 37].”
Cited by
Supervised autonomous robotic soft tissue surgery
Shademan, A., Decker, R. S., Opfermann, J. D., Leonard, S., Krieger, A., & Kim, P. C. W. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad9398 · Cited by 620
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Autonomous robotic laparoscopic surgery for intestinal anastomosis
Saeidi, H., Opfermann, J. D., Kam, M., Wei, S., Leonard, S., Hsieh, M. H., Kang, J. U., & Krieger, A. (2022) · Science Robotics · doi:10.1126/scirobotics.abj2908 · Cited by 384
Autonomy for Surgical Robots: Concepts and Paradigms
Haidegger, T. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2913282 · Cited by 306
Haptics in Robot-Assisted Surgery: Challenges and Benefits
Enayati, N., De Momi, E., & Ferrigno, G. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2538080 · Cited by 252
“of surgical subtasks [15] is encouraging, but far from approvable for clinical implementation and replacing clinicians.”
Metadata
- Authors
- Murali, A., Sen, S., Kehoe, B., Garg, A., McFarland, S., Patil, S., Boyd, W. D., Lim, S., Abbeel, P., & Goldberg, K.
- Venue
- 2015 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2015-05
- Pages
- 1202-1209
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W1584687743
- Cited by
- 178
- References
- 3
- FWCI
- 115.29
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.