Semi-autonomous simulated brain tumor ablation with RAVENII Surgical Robot using behavior tree
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Medical robots have been widely used to assist surgeons to carry out dexterous surgical tasks via various ways. Most of the tasks require surgeon's operation directly or indirectly. Certain level of autonomy in robotic surgery could not only free the surgeon from some tedious repetitive tasks, but also utilize the advantages of robot: high dexterity and accuracy. This paper presents a semi-autonomous neurosurgical procedure of brain tumor ablation using RAVEN Surgical Robot and stereo visual feedback. By integrating with the behavior tree framework, the whole surgical task is modeled flexibly and intelligently as nodes and leaves of a behavior tree. This paper provides three contributions mainly: (1) describing the brain tumor ablation as an ideal candidate for autonomous robotic surgery, (2) modeling and implementing the semi-autonomous surgical task using behavior tree framework, and (3) designing an experimental simulated ablation task for feasibility study and robot performance analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MonoSLAM: Real-time single camera SLAM
Davison, A. J., Reid, I. D., Molton, N. D., & Stasse, O. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1049 · Cited by 3,959 · cited 1×
“Nonetheless, the position of the robot end-effector may be estimated from the SFE image using machine vision techniques (visual SLAM [29]).”
Method
Cited by
Supervised autonomous robotic soft tissue surgery
Shademan, A., Decker, R. S., Opfermann, J. D., Leonard, S., Krieger, A., & Kim, P. C. W. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad9398 · Cited by 620
Behavior Trees in Robotics and AI
Colledanchise, M., & Ögren, P. (2018) · CRC Press eBooks · doi:10.1201/9780429489105 · Cited by 526
A survey of Behavior Trees in robotics and AI
Iovino, M., Scukins, E., Styrud, J., Ögren, P., & Smith, C. (2022) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2022.104096 · Cited by 306
Colledanchise, M., & Ogren, P. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2633567 · Cited by 209
Towards Blended Reactive Planning and Acting using Behavior Trees
Colledanchise, M., Almeida, D., & Ogren, P. (2019) · 2019 International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2019.8794128 · Cited by 133
Metadata
- Authors
- Hu, D., Gong, Y., Hannaford, B., & Seibel, E. J.
- Venue
- 2015 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2015-05
- Volume
- 2015
- Pages
- 3868-3875
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W1588269491
- Cited by
- 115
- References
- 1
- FWCI
- 26.77
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Semi-autonomous simulated brain tumor ablation with RAVENII Surgical Robot using behavior tree. https://app.cochat.ai/papers/10.1109/icra.2015.7139738
- The paper
- Hu, D., Gong, Y., Hannaford, B., & Seibel, E. J. (2015). Semi-autonomous simulated brain tumor ablation with RAVENII Surgical Robot using behavior tree. 2015 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2015.7139738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.