Packaging of Implantable Microsystems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Challenges and technologies for long-term stable packaging of implantable devices and microsystems are reviewed. Packaging of implantable microsystems is especially difficult because of the many limitations in terms of size, material properties, mechanical structure and rigidity, biocompatibility, required lifetime, and maximum allowable temperature. Our group has demonstrated their long-term reliability in salt water and biological environments. Glass packages anodically bonded to silicon substrates containing integrated sensors/circuits provide a mean-time-to-failure (MTTF) of >100 years in saline solutions under accelerated conditions, and a lifetime of almost two years in biological tissue1. Thin film coatings of electroplated gold have also been used for packaging of implantable microprobes and shown to be hermetic under accelerated conditions and provide a MTTF of ~40 years. Polymer films, such as Parylene, are of particular interest for many biomedical microsystems because of their flexibility and ease of use. Long-term testing of passive implantable sensors using these films has also been demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citation
Cited by
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
“Packaging of implanted devices is very important for chronic use and has been explored extensively since the late 1980s [51].”
BackgroundSelf-citationLamont, C., Grego, T., Nanbakhsh, K., Shah Idil, A., Giagka, V, Vanhoestenberghe, A., Cogan, S., & Donaldson, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf0d6 · Cited by 28
Metadata
- Authors
- Najafi, K.
- Venue
- 2007 IEEE Sensors
- Publisher
- IEEE
- Published
- 2007
- Pages
- 58-63
- ISSN
- 1930-0395 (ISSN-L)
- OpenAlex
- W2107464547
- Cited by
- 38
- References
- 1
- FWCI
- 11.37
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Packaging of Implantable Microsystems. https://app.cochat.ai/papers/10.1109/icsens.2007.4388335
- The paper
- Najafi, K. (2007). Packaging of Implantable Microsystems. 2007 IEEE Sensors. https://doi.org/10.1109/icsens.2007.4388335
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.