The DOI matches its Crossref record.
Experimental Evaluation of Grid-Forming Inverters Under Unbalanced and Fault Conditions
Abstract
With inverter-based distributed energy resources (DERs) becoming more prevalent in grid-connected or islanded distribution feeders, a better understanding of the performance of these devices is needed. Increasing the amount of inverter-based generation, and therefore reducing conventional generation, i.e. rotating machines and synchronous generators, decreases generation sources with well-known characteristic responses for unbalanced and transient fault conditions. This paper experimentally tests the performance of commercial grid-forming inverters under fault and unbalanced conditions and provides a comparison between grid-forming inverters and their grid-following counterparts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- 10.1109/COMPEL.2019.8769663 · DOI
- 10.1109/ChiCC.2015.7261074 · DOI
- 10.1109/PESGM.2018.8586162 · DOI
- 10.1109/ECCE.2015.7309831 · DOI
- 10.1109/TPWRS.2020.2968114 · DOI
- 10.1109/PVSC.2018.8547449 · DOI
- 10.1109/PVSC40753.2019.8980892 · DOI · Paper page
- glover, 2017, Power System Analysis and Design
- tleis, 2019, Power Systems Modelling and Fault Analysis Theory and Practice
- 10.1109/PVSC40753.2019.8980944 · DOI
- nikkhajoei, 2006, Microgrid Fault Protection Based on Symmetrical and Differential Current Components, Public Interest Energy Research California Energy Commission
- 10.2172/971441 · DOI
- 10.1109/TPWRD.2019.2907462 · DOI
- 10.1109/EPEC.2012.6474945 · DOI
Cited by
Sorted by citations
Small-Signal Analysis of Current-Limiting Grid-Forming Inverters
Yang, B., Baeckeland, N., & Seo, G.-S. (2026) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2026.3655646 · Cited by 2
Metadata
- Authors
- Gurule, N. S., Hernandez-Alvidrez, J., Darbali-Zamora, R., Reno, M. J., & Flicker, J. D.
- Affiliations
- Sandia National Laboratories (US)
- Sandia National Laboratories,Albuquerque,New Mexico,USA
- Venue
- IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2020-10-18
- Pages
- 4057-4062
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W3098113960
- Cited by
- 22
- References
- 0
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 5 · 2023: 2 · 2022: 6 · 2021: 4
- FWCI
- 4.50
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual Conference of the IEEE Industrial Electronics Society (IECON) (publishedVersion)
- Funders
- U.S. Department of Energy
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- grid-forming inverters, grid-following inverters, inverter-based distributed energy resources, unbalanced conditions, transient faults
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review