Whole sensory nerve recordings with spiral nerve cuff electrode
Abstract
We have used a self-curling nerve cuff electrode to record sensory information from a cutaneous nerve. This type of cuffs has previously been used only for stimulation, but its mechanical properties could make it very suitable for recording also, since it can be fitted closer to the nerve than traditional cuffs without compromising the nerve. In this study we show that it is possible to record neural signals with at least the same quality as traditional cuffs.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Extrafascicular electrodes such as nerve cuff electrodes transduce signals with amplitudes below 20 μVpp.
“In addition, the signals transduced by extrafascicular electrodes, such as nerve cuff electrodes, have amplitudes less than 20 µVpp [41, 75, 127, 138].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [127]
Cites
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · see citing works
Neural prostheses : replacing motor function after disease or disability
Stein, R. B., Peckham, P. H., & Popović, D. B. (1992) · Oxford University Press eBooks · Cited by 117 · see citing works
Whole Sensory Nerve Recordings In Human - An Application For Neural Prostheses
Sinkjær, T., Haugland, M. K., Haase, J., & Hoffer, J. A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684252 · Cited by 7 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
- Authors
- Sinjar, T., Hinge, B., Jorgensen, A., Jensen, M. L., & Haugland, M.
- Affiliations
- Aalborg University (DK)
- Aalborg University Hospital (DK)
- Venue
- Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 1992-10
- Pages
- 1330-1331
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W1980908103
- Cited by
- 2
- References
- 3
- Citations by year
- 2016: 1
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- cutaneous nerves, neural recording, cuff electrodes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review