Tripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Properties of nerve cuff recording electrodes were analyzed. Tripolar cuff electrodes have to be described essentially different for (propagating) nerve signals inside the cuff, and electrical muscle activity and stimulus artifacts arising from sources outside the cuff. It was experimentally shown that the signals originating outside the cuff are differently and much stronger influenced by the addition of a balancing resister to the outer cuff electrodes than the nerve signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159
Research works printed but not linked: 3
- 10.1385/0-89603-185-3:65 · DOI · Paper page
- 10.1109/IEMBS.1994.415465 · DOI
- stein, 1975, Principles underlying new methods for chronic neural recording, J Can Sci Neurol, 2, 235, 10.1017/S0317167100020333 · DOI · Paper page
Cited by
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Self-citationCompliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“[71] Struijk J J and Thomsen M 1995 Tripolar nerve cuff”
BackgroundElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Tejeiro, C., Shoukry, A., Tang, C., Kilinc, E., Joshi, J., et al. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3113354 · Cited by 48
Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2607520 · Cited by 44
“Signals obtained by extraneural electrodes are small in amplitude and thus susceptible to interfering noise such as EMG, triboelectric, or movement artifacts [11]–[13].”
Background
Metadata
- Authors
- Struijk, J. J., & Thomsen, M.
- Venue
- Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2002-11-19
- Volume
- 2
- Pages
- 1105-1106
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2146500815
- Cited by
- 76
- References
- 1
- FWCI
- 14.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal. https://app.cochat.ai/papers/10.1109/iembs.1995.579534
- The paper
- Struijk, J. J., & Thomsen, M. (2002). Tripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal. Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.1995.579534
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.