CoChat

Compliant peripheral nerve interfaces.

Open access
Paggi, Valentina, Akouissi, Outman, Micera, Silvestro, Lacour, Stéphanie P · 2021 · Journal of Neural Engineering

The DOI matches its Crossref record; 247 of the 253 references it cites were found in a registry or an index; none of the 3 sources its claims cite is checked for support yet.

Abstract

This paper reviews recent progress in the development of flexible and implantable PNIs, highlighting materials selection, fabrication methods, and interface designs.

Overview

CoChat Summary

TL;DR

This topical review surveys recent progress in mechanically compliant peripheral nerve interfaces (PNIs), focusing on materials, fabrication, and integrated functions for flexible implantable systems. It argues that long-term PNI performance is limited by implant–tissue damage and foreign body response, and that compliance is a key strategy to improve chronic function.

Key findings

  • PNIs are used for both research and therapy, including closed-loop control of neuroprosthetic limbs, treatment of neuropathic pain, and restoration of functions such as breathing and bladder management.
  • The review highlights three main interface classes: intraneural, extraneural, and regenerative, and three modulation modalities: electrical, optical, and chemical.
  • A central challenge is that implantable PNIs can provide enhanced selectivity over non-invasive approaches, but their long-term functionality is limited by tissue damage at the implant–tissue interface.
  • The paper emphasizes that compliant PNIs are designed to match nerve anatomy and dynamic motion in order to limit foreign body response.

Methods

  • Topical review article: the paper synthesizes recent literature rather than reporting a new experimental study.
  • Scope of the review covers flexible and implantable PNIs, with attention to materials selection, fabrication methods, integrated functions, and interface design categories.
  • Main analysis is qualitative and comparative, discussing design trade-offs and challenges in integrating PNIs on compliant substrates.

Limitations

  • The paper does not present original experimental data or a quantitative meta-analysis; this is evident from the text as a review article.
  • It states that long-term functionality remains limited by tissue damage and implant–tissue interface issues, indicating an unresolved design limitation.
  • The text makes clear that integrating electrical, optical, and chemical functions on compliant substrates remains challenging.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1088/1741-2552/abcdbe

Cites

247 of 247 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 2 Not valid · 2 Not checked · 5 Own results and interpretations

1 reference still to check

A free account verifies the references that are still open.

Verify 1 reference — free account
  • Probably not a substantial claim. 7
  • It may state two separate claims as one. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 247 references

Cited by

See all 60

Metadata

Authors
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P.
Affiliations
  • École Polytechnique Fédérale de Lausanne (CH)
  • Scuola Superiore Sant'Anna (IT)
Corresponding author
  • Micera, Silvestro
  • Lacour, Stéphanie P
Venue
Journal of Neural Engineering
Published
2021-03-08
Volume
18
Issue
3
Pages
031001
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W3137684282
Cited by
60
References
253
Citations by year
2026: 4 · 2025: 10 · 2024: 16 · 2023: 11 · 2022: 14 · 2021: 5
FWCI
1.74
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Neural Engineering (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
Funders
  • Fondation Bertarelli
  • Horizon 2020 Framework Programme (NeuTouch 813713)
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CHRONOS)
  • H2020 Marie Skłodowska-Curie Actions (754354)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
peripheral nerve interfaces, implantable neural interfaces, flexible electronics, biocompatibility, foreign body reaction, neural recording, neurostimulation, optical stimulation, chemical stimulation, implant-tissue interface, neuroprosthetics, neuropathic pain
MeSH terms
Neurosciences, Peripheral Nerves, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compliant peripheral nerve interfaces. https://app.cochat.ai/papers/10.1088/1741-2552/abcdbe
The paper
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021). Compliant peripheral nerve interfaces. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/abcdbe

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.