The kinematics of the swing phase obtained from accelerometer and gyroscope measurements
Open accessThe DOI matches its Crossref record.
Abstract
The kinematics needed to calculate the knee moment during the initial swing phase were obtained from a set of eight leg-mounted uni-axial accelerometers and two gyroscopes. The angular and linear accelerations of shank and thigh were calculated from the signals of two accelerometers mounted on each of the leg segments directed tangentially and radially to the movement. The angular velocities of shank and thigh were measured by the gyroscopes. The absolute angles of shank and thigh were obtained by integration of the gyroscope signal plus an added offset angle, estimated from radial and tangential accelerometer signals registered while standing. Movement was assumed to be in the saggital plane. The accuracy of the quantities found from the leg mounted sensors was calculated in terms of correlation and the RMS error by comparing against measurements obtained by a VICON/sup TM/ system. The results were indistinguishable. The system was later applied in research measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
“(1996) [13] had showed that shank inclination could be measured with eight accelerometers and two gyroscopes fixed on two rigid metal plates.”
BackgroundDejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286
“Heyn et al. [ 12 ] showed that shank and thigh inclination angles can be measured with eight accelerometers and two gyroscopes fixed on two rigid metal plates as well.”
BackgroundFong, D. T.-P., & Chan, Y.-Y. (2010) · Sensors · doi:10.3390/s101211556 · Cited by 286
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Dejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189
Metadata
- Authors
- Heyn, A., Mayagoitia, R. E., Nene, A. V., & Veltink, P. H.
- Venue
- Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2002-12-24
- Volume
- 2
- Pages
- 463-464
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2533572063
- Cited by
- 24
- References
- 0
- FWCI
- 1.34
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The kinematics of the swing phase obtained from accelerometer and gyroscope measurements. https://app.cochat.ai/papers/10.1109/iembs.1996.651817
- The paper
- Heyn, A., Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002). The kinematics of the swing phase obtained from accelerometer and gyroscope measurements. Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.1996.651817
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.