A virtual reality based exercise system for hand rehabilitation post-stroke: transfer to function
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present preliminary results from a virtual reality (VR)-based system for hand rehabilitation that uses a CyberGlove and a Rutgers Master II-ND haptic glove. This system trains finger range of motion, finger flexion speed, independence of finger motion and finger strength. Eight chronic post-stroke subjects participated. In keeping with variability in both the lesion site and in initial upper extremity function, each subject showed improvement on a unique combination of movement parameters in VR training. These improvements transferred to gains on clinical tests, as well as to significant reductions in task completion times for the prehension of real objects. These results are indicative of the potential feasibility of this exercise system for rehabilitation in patients with hand dysfunction resulting from neurological impairment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Virtual Environment Training: A New Tool for Neurorehabilitation
Holden, M. K., & Dyar, T. (2002) · Neurology Report · doi:10.1097/01253086-200226020-00003 · Cited by 168
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
A Survey of Glove-Based Systems and Their Applications
Dipietro, L., Sabatini, A. M., & Dario, P. (2008) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2008.923862 · Cited by 691
Sensorimotor training in virtual reality: A review
Adamovich, S. V., Fluet, G. G., Tunik, E., & Merians, A. S. (2009) · NeuroRehabilitation · doi:10.3233/nre-2009-0497 · Cited by 507
Self-citationDevelopments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Connelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047588 · Cited by 271
The potential of virtual reality and gaming to assist successful aging with disability
Lange, B. S., Requejo, P., Flynn, S. M., Rizzo, A. A., Valero-Cuevas, F. J., Baker, L., & Winstein, C. (2010) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2009.12.007 · Cited by 208
Exploration of Force Myography and surface Electromyography in hand gesture classification
Jiang, X., Merhi, L.-K., Xiao, Z. G., & Menon, C. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.015 · Cited by 172
Lange, B., Flynn, S., & Rizzo, A. (2009) · Physical Therapy Reviews · doi:10.1179/108331909x12488667117258 · Cited by 160
A low cost instrumented glove for extended monitoring and functional hand assessment
Simone, L. K., Sundarrajan, N., Luo, X., Jia, Y., & Kamper, D. G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.021 · Cited by 154
Metadata
- Authors
- Adamovich, S. V., Merians, A. S., Boian, R., Tremaine, M., Burdea, G. S., Recce, M., & Poizner, H.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-03-21
- Volume
- 4
- Pages
- 4936-4939
- OpenAlex
- W2531959305
- Cited by
- 101
- References
- 1
- FWCI
- 3.16
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.