The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Pneumatic Glove and Immersive Virtual Reality Environment for Hand Rehabilitative Training After Stroke
Abstract
While a number of devices have recently been developed to facilitate hand rehabilitation after stroke, most place some restrictions on movement of the digits or arm. Thus, a novel glove was developed which can provide independent extension assistance to each digit while still allowing full arm movement. This pneumatic glove, the PneuGlove, can be used for training grasp-and-release movements either with real objects or with virtual objects in a virtual reality environment. Two groups of stroke survivors, with seven subjects in each group, completed a six-week rehabilitation training protocol, consisting of three 1-h sessions held each week. One group wore the PneuGlove during training, performed both within a novel virtual reality environment and outside of it with physical objects, while the other group completed the same training without the device. Across subjects, significant improvements were observed in the Fugl-Meyer Assessment for the upper extremity (p < 0.001), the hand/wrist portion of the Fugl-Meyer Assessment (p < 0.001), the Box and Blocks test (p < 0.005), and palmar pinch strength (p < 0.005). While changes in the two groups were not statistically different, the group using the PneuGlove did show greater mean improvement on each of these measures, such as gains of 3.7 versus 2.4 points on the hand/wrist portion of the Fugl-Meyer Assessment and 14 N versus 5 N in palmar pinch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
The impact of physical therapy on functional outcomes after stroke: what's the evidence?
Van Peppen, R. P., Kwakkel, G., Wood-Dauphinee, S., Hendriks, H. J., Van der Wees, P. J., & Dekker, J. (2004) · Clinical Rehabilitation · doi:10.1191/0269215504cr843oa · Cited by 942
A low cost instrumented glove for extended monitoring and functional hand assessment
Simone, L. K., Sundarrajan, N., Luo, X., Jia, Y., & Kamper, D. G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.021 · Cited by 154
Self-citation
Cited by
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Robot-assisted Therapy in Stroke Rehabilitation
Chang, W. H., & Kim, Y.-H. (2013) · Journal of Stroke · doi:10.5853/jos.2013.15.3.174 · Cited by 499
Kang, B. B., Choi, H., Lee, H., & Cho, K.-J. (2019) · Soft Robotics · doi:10.1089/soro.2018.0006 · Cited by 257
Winther, F., Ravindran, L., Svendsen, K. P., & Feuchtner, T. (2020) · 2020 IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr46266.2020.00097 · Cited by 37
Metadata
- Authors
- Connelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-10
- Volume
- 18
- Issue
- 5
- Pages
- 551-559
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2119779012
- Cited by
- 271
- References
- 3
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Pneumatic Glove and Immersive Virtual Reality Environment for Hand Rehabilitative Training After Stroke. https://app.cochat.ai/papers/10.1109/tnsre.2010.2047588
- The paper
- Connelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G. (2010). A Pneumatic Glove and Immersive Virtual Reality Environment for Hand Rehabilitative Training After Stroke. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2010.2047588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.