CoChat

Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control

Weir, R.F., Troyk, P.R., DeMichele, G., Kerns, D. · 2005 · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
Cited by 40

The DOI matches its Crossref record.

Abstract

The limitation of current prostheses is not the devices themselves but rather the lack of sufficient independent control sources. A system capable of reading intra muscular EMG signals would greatly increase the number control sources available for prosthesis control. We are developing a multichannel/multifunction prosthetic hand/arm controller system capable of receiving and processing signals from up to sixteen implanted bipolar differential electromyographic (EMG) electrodes. An external prosthesis controller will decipher user intent from telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link will provide power for the implanted electrodes. This paper describes some of the technical aspects of the implant and telemetry design.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2005.1616206

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Weir, R. F., Troyk, P. R., DeMichele, G., & Kerns, D.
Venue
2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
Publisher
IEEE
Published
2005
Volume
2005
Pages
7337-40
OpenAlex
W1988400307
Cited by
40
References
0
FWCI
7.77
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control. https://app.cochat.ai/papers/10.1109/iembs.2005.1616206
The paper
Weir, R. F., Troyk, P. R., DeMichele, G., & Kerns, D. (2005). Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control. 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference. https://doi.org/10.1109/iembs.2005.1616206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.